Goiter with substernal extension is common, with a reported incidence of up to 20% in patients undergoing thyroidectomy. It has been shown that the vast majority of substernal goiters can be removed through a cervical incision. However, if this is not possible, a sternotomy is usually required, which could add significant morbidity to an otherwise routine operation. During substernal mobilization, the surgeon's finger is typically placed under the strap muscles and against the thyroid capsule, hooking around the inferior aspect of the gland to facilitate separation of the gland from its mediastinal attachments. In cases where the length required for successful substernal mobilization is beyond the reach of a surgeon's fingers, the use of an alternative strategy may be required. A surgical spoon is a blunt, curved instrument that can allow safe substernal mobilization while providing the added length needed when digital mobilization is inadequate. Here, we describe the use of a surgical spoon for the safe and successful removal of a goiter with substernal extension unable to be removed with digital manipulation.