1.
J Electr Bioimpedance ; 13(1): 45-53, 2022 Jan.
Article in English | MEDLINE | ID: mdl-36196240

ABSTRACT

At present, there are no hardware or biochemical systems that allow to assess the severity of post-COVID syndrome in vivo. The hardware of the proposed biotechnical system is based on routine transthoracic electrical impedance rheography, which makes it possible to register the frequency characteristics of the patient's bioimpedance response to controlled stress stimulation, thereby simultaneously fixing the characteristics of his productive heart, the state of the hemomicrocirculatory bed, the efficiency of the gas transport function of his blood, and also reliably assess personal reactivity and adaptive potential. Subsequent mathematical approximation of the obtained biometric data by an original neural network makes it possible to rank the results obtained and automatically generate a program of medical rehabilitation for a particular patient, depending on the severity of his post-COVID syndrome. The study results proved two reliable physiological signs confirming the presence of latent post-COVID complications: a decrease in the base impedance value for light exercise and an increase in the length of the systolic arc of the rheocardiogram.

2.
Sensors (Basel) ; 22(2)2022 Jan 15.
Article in English | MEDLINE | ID: mdl-35062626

ABSTRACT

A venipuncture is the most common non-invasive medical procedure, and is frequently used with patients; however, a high probability of post-injection complications accompanies intravenous injection. The most common complication is a hematoma, which is associated with puncture of the uppermost and lowermost walls. To simplify and reduce complications of the venipuncture procedure, and as well as automation of this process, a device that can provide information of the needle tip position into patient's tissues needs to be developed. This paper presents a peripheral vascular puncture control system based on electrical impedance measurements. A special electrode system was designed to achieve the maximum sensitivity for puncture identification using a traditional needle, which is usually used in clinical practice. An experimental study on subjects showed that the electrical impedance signal changed significantly once the standard needle entered the blood vessel. On basis of theoretical and experimental studies, a decision rule of puncture identification based on the analysis of amplitude-time parameters of experimental signals was proposed. The proposed method was tested on 15 test and 9 control samples, with the results showing that 97% accuracy was obtained.


Subject(s)
Needles , Punctures , Electric Impedance , Electrodes , Humans