Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Micromachines (Basel) ; 15(5)2024 May 01.
Article in English | MEDLINE | ID: mdl-38793191

ABSTRACT

This study aims to provide condensation heat transfer coefficients of R600a (isobutane) refrigerant under mass fluxes between 50 and 98 kg/m2·s at saturation temperatures of 35 °C, 40 °C and 45 °C. Additionally, experiments are conducted with varying inlet vapour quality to understand its effect on the condensation heat transfer measurement. An aluminium multiport microchannel with a hydraulic diameter (Dh) of 0.399 mm is used, where a plexiglass cover is mounted on the top of the microchannels to observe the flow conditions. A 1D heat transfer through the aluminium block is assumed, and heat flux through the refrigerant to the coolant is measured to obtain condensation heat transfer coefficients of R600a. The results showed that decreasing saturation temperature and increasing vapour quality increase the condensation heat transfer coefficient. Increasing refrigerant mass flux increases the heat transfer coefficient up to a specific mass flux. It is observed that the effect of inlet vapour quality becomes significant as introduced quality decreases due to increasing fluctuation.

2.
Micromachines (Basel) ; 11(4)2020 Apr 14.
Article in English | MEDLINE | ID: mdl-32295138

ABSTRACT

Label-free, size-dependent cell-sorting applications based on inertial focusing phenomena have attracted much interest during the last decade. The separation capability heavily depends on the precision of microparticle focusing. In this study, five-loop spiral microchannels with a height of 90 µm and a width of 500 µm are introduced. Unlike their original spiral counterparts, these channels have elliptic configurations of varying initial aspect ratios, namely major axis to minor axis ratios of 3:2, 11:9, 9:11, and 2:3. Accordingly, the curvature of these configurations increases in a curvilinear manner through the channel. The effects of the alternating curvature and channel Reynolds number on the focusing of fluorescent microparticles with sizes of 10 and 20 µm in the prepared suspensions were investigated. At volumetric flow rates between 0.5 and 3.5 mL/min (allowing separation), each channel was tested to collect samples at the designated outlets. Then, these samples were analyzed by counting the particles. These curved channels were capable of separating 20 and 10 µm particles with total yields up to approximately 95% and 90%, respectively. The results exhibited that the level of enrichment and the focusing behavior of the proposed configurations are promising compared to the existing microfluidic channel configurations.

SELECTION OF CITATIONS
SEARCH DETAIL
...