Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 96
Filter
1.
Clin Nutr ; 43(6): 1627-1634, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38772069

ABSTRACT

BACKGROUND & AIMS: Loss of venous access is threatening for patients with intestinal failure (IF) under long-term parenteral nutrition (PN). We aimed to identify the incidence of central venous catheter (CVC) complications, compare different devices, and analyze interventional recanalizing procedures to restore the patency of occluded CVCs. METHODS: For this retrospective cohort study, patient data from a prospective IF database spanning 16 years was analyzed at a tertiary referral center. Catheter dwell times (CDTs) were distinguished by Kaplan-Meier survival analysis and subgroup analyses were performed for different CVC types (tunneled/port catheters). Specific complications (occlusion, catheter-related infection (CRI), displacement, and material defect) were analyzed. Explantation rates and CDTs were compared. RESULTS: Overall, 193 CVCs in 77 patients with IF under PN could be enrolled (62.524 "CVC-days"). Broviac type "B" was found to be significantly superior to type "A" regarding occlusion, CRI, and material defects (log-rank test: p = 0.05; p = 0.026; p = 0.005 respectively). Port catheters were displaying the highest incidence of CRI (2.13 events/1000 catheter days). Interventional catheter recanalization was performed 91 times and significantly increased the CDT from a median of 131 days (IQR: 62; 258) to 389 days (IQR: 262; 731) (Mann-Whitney-U-test: p= <0.001) without increasing complications. CONCLUSIONS: Different complication rates and CDT were seen depending on CVC type. Tunneled catheters were significantly superior concerning CRI. Interventional catheter recanalization is a viable alternative to fibrinolytics to restore CVC patency, but long-term patency data is scarce.


Subject(s)
Catheter-Related Infections , Central Venous Catheters , Intestinal Failure , Humans , Male , Female , Retrospective Studies , Central Venous Catheters/adverse effects , Middle Aged , Incidence , Catheter-Related Infections/epidemiology , Intestinal Failure/therapy , Parenteral Nutrition , Catheterization, Central Venous/adverse effects , Catheterization, Central Venous/methods , Adult , Aged , Catheter Obstruction/statistics & numerical data
2.
Heliyon ; 10(6): e28142, 2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38533048

ABSTRACT

Rationale and objectives: Aim of this study was to assess the impact of contrast media dose (CMD) reduction on diagnostic quality of photon-counting detector CT (PCD-CT) and energy-integrating detector CT (EID-CT). Methods: CT scans of the abdominal region with differing CMD acquired in portal venous phase on a PCD-CT were included and compared to EID-CT scans. Diagnostic quality and contrast intensity were rated. Additionally, readers had to assign the scans to reduced or regular CMD. Regions-of-interest (ROIs) were placed in defined segments of portal vein, inferior vena cava, liver, spleen, kidneys, abdominal aorta and muscular tissue. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Results: Overall 158 CT scans performed on a PCD-CT and 68 examinations on an EID-CT were analyzed. Overall diagnostic quality showed no significant differences for PCD-CT with standard CMD which scored a median 5 (IQR:5-5) and PCD-CT with 70% CMD scoring 5 (4-5). (For PCD-CT, 71.69% of the examinations with reduced CMD were assigned to regular CMD by the readers, for EID-CT 9.09%. Averaged for all measurements SNR for 50% CMD was reduced by 19% in PCD-CT (EID-CT 34%) and CNR by 48% (EID-CT 56%). Virtual monoenergetic images (VMI)50keV for PCD-CT images acquired with 50% CMD showed an increase in SNR by 72% and CNR by 153%. Conclusions: Diagnostic interpretability of PCD-CT examinations with reduction of up to 50% CMD is maintained. PCD-CT deducted scans especially with 70% CMD were often not recognized as CMD reduced scans. Compared to EID-CT less decline in SNR and CNR is observed for CMD reduced PCD-CT images. Employing VMI50keV for CMD-reduced PCD-CT images compensated for the effects.

3.
J Cardiovasc Magn Reson ; 26(1): 101035, 2024 Mar 07.
Article in English | MEDLINE | ID: mdl-38460841

ABSTRACT

BACKGROUND: Patients are increasingly using Generative Pre-trained Transformer 4 (GPT-4) to better understand their own radiology findings. PURPOSE: To evaluate the performance of GPT-4 in transforming cardiovascular magnetic resonance (CMR) reports into text that is comprehensible to medical laypersons. METHODS: ChatGPT with GPT-4 architecture was used to generate three different explained versions of 20 various CMR reports (n = 60) using the same prompt: "Explain the radiology report in a language understandable to a medical layperson". Two cardiovascular radiologists evaluated understandability, factual correctness, completeness of relevant findings, and lack of potential harm, while 13 medical laypersons evaluated the understandability of the original and the GPT-4 reports on a Likert scale (1 "strongly disagree", 5 "strongly agree"). Readability was measured using the Automated Readability Index (ARI). Linear mixed-effects models (values given as median [interquartile range]) and intraclass correlation coefficient (ICC) were used for statistical analysis. RESULTS: GPT-4 reports were generated on average in 52 s ± 13. GPT-4 reports achieved a lower ARI score (10 [9-12] vs 5 [4-6]; p < 0.001) and were subjectively easier to understand for laypersons than original reports (1 [1] vs 4 [4,5]; p < 0.001). Eighteen out of 20 (90%) standard CMR reports and 2/60 (3%) GPT-generated reports had an ARI score corresponding to the 8th grade level or higher. Radiologists' ratings of the GPT-4 reports reached high levels for correctness (5 [4, 5]), completeness (5 [5]), and lack of potential harm (5 [5]); with "strong agreement" for factual correctness in 94% (113/120) and completeness of relevant findings in 81% (97/120) of reports. Test-retest agreement for layperson understandability ratings between the three simplified reports generated from the same original report was substantial (ICC: 0.62; p < 0.001). Interrater agreement between radiologists was almost perfect for lack of potential harm (ICC: 0.93, p < 0.001) and moderate to substantial for completeness (ICC: 0.76, p < 0.001) and factual correctness (ICC: 0.55, p < 0.001). CONCLUSION: GPT-4 can reliably transform complex CMR reports into more understandable, layperson-friendly language while largely maintaining factual correctness and completeness, and can thus help convey patient-relevant radiology information in an easy-to-understand manner.

4.
Front Radiol ; 4: 1346550, 2024.
Article in English | MEDLINE | ID: mdl-38445105

ABSTRACT

Purpose: Due to a lack of data, there is an ongoing debate regarding the optimal frontline interventional therapy for unresectable hepatocellular carcinoma (HCC). The aim of the study is to compare the results of transarterial radioembolization (TARE) as the first-line therapy and as a subsequent therapy following prior transarterial chemoembolization (TACE) in these patients. Methods: A total of 83 patients were evaluated, with 38 patients having undergone at least one TACE session prior to TARE [27 male; mean age 67.2 years; 68.4% stage Barcelona clinic liver cancer (BCLC) B, 31.6% BCLC C]; 45 patients underwent primary TARE (33 male; mean age 69.9 years; 40% BCLC B, 58% BCLC C). Clinical [age, gender, BCLC stage, activity in gigabecquerel (GBq), Child-Pugh status, portal vein thrombosis, tumor volume] and procedural [overall survival (OS), local tumor control (LTC), and progression-free survival (PFS)] data were compared. A regression analysis was performed to evaluate OS, LTC, and PFS. Results: No differences were found in OS (95% CI: 1.12, P = 0.289), LTC (95% CI: 0.003, P = 0.95), and PFS (95% CI: 0.4, P = 0.525). The regression analysis revealed a relationship between Child-Pugh score (P = 0.005), size of HCC lesions (>10 cm) (P = 0.022), and OS; neither prior TACE (Child-Pugh B patients; 95% CI: 0.120, P = 0.729) nor number of lesions (>10; 95% CI: 2.930, P = 0.087) correlated with OS. Conclusion: Prior TACE does not affect the outcome of TARE in unresectable HCC.

5.
J Thorac Imaging ; 2024 Feb 22.
Article in English | MEDLINE | ID: mdl-38389116

ABSTRACT

PURPOSE: Inflammatory changes in epicardial (EAT) and pericardial adipose tissue (PAT) are associated with increased overall cardiovascular risk. Using routine, preinterventional cardiac CT data, we examined the predictive value of quantity and quality of EAT and PAT for outcome after transcatheter aortic valve replacement (TAVR). MATERIALS AND METHODS: Cardiac CT data of 1197 patients who underwent TAVR at the in-house heart center between 2011 and 2020 were retrospectively analyzed. The amount and density of EAT and PAT were quantified from single-slice CT images at the level of the aortic valve. Using established risk scores and known independent risk factors, a clinical benchmark model (BMI, Chronic kidney disease stage, EuroSCORE 2, STS Prom, year of intervention) for outcome prediction (2-year mortality) after TAVR was established. Subsequently, we tested whether the additional inclusion of area and density values of EAT and PAT in the clinical benchmark model improved prediction. For this purpose, the cohort was divided into a training (n=798) and a test cohort (n=399). RESULTS: Within the 2-year follow-up, 264 patients died. In the training cohort, particularly the addition of EAT density to the clinical benchmark model showed a significant association with outcome (hazard ratio 1.04, 95% CI: 1.01-1.07; P =0.013). In the test cohort, the outcome prediction of the clinical benchmark model was also significantly improved with the inclusion of EAT density (c-statistic: 0.589 vs. 0.628; P =0.026). CONCLUSIONS: EAT density as a surrogate marker of EAT inflammation was associated with 2-year mortality after TAVR and may improve outcome prediction independent of established risk parameters.

6.
Front Cardiovasc Med ; 11: 1323443, 2024.
Article in English | MEDLINE | ID: mdl-38410246

ABSTRACT

Purpose: This study aims to evaluate deep learning (DL) denoising reconstructions for image quality improvement of Doppler ultrasound (DUS)-gated fetal cardiac MRI in congenital heart disease (CHD). Methods: Twenty-five fetuses with CHD (mean gestational age: 35 ± 1 weeks) underwent fetal cardiac MRI at 3T. Cine imaging was acquired using a balanced steady-state free precession (bSSFP) sequence with Doppler ultrasound gating. Images were reconstructed using both compressed sensing (bSSFP CS) and a pre-trained convolutional neural network trained for DL denoising (bSSFP DL). Images were compared qualitatively based on a 5-point Likert scale (from 1 = non-diagnostic to 5 = excellent) and quantitatively by calculating the apparent signal-to-noise ratio (aSNR) and contrast-to-noise ratio (aCNR). Diagnostic confidence was assessed for the atria, ventricles, foramen ovale, valves, great vessels, aortic arch, and pulmonary veins. Results: Fetal cardiac cine MRI was successful in 23 fetuses (92%), with two studies excluded due to extensive fetal motion. The image quality of bSSFP DL cine reconstructions was rated superior to standard bSSFP CS cine images in terms of contrast [3 (interquartile range: 2-4) vs. 5 (4-5), P < 0.001] and endocardial edge definition [3 (2-4) vs. 4 (4-5), P < 0.001], while the extent of artifacts was found to be comparable [4 (3-4.75) vs. 4 (3-4), P = 0.40]. bSSFP DL images had higher aSNR and aCNR compared with the bSSFP CS images (aSNR: 13.4 ± 6.9 vs. 8.3 ± 3.6, P < 0.001; aCNR: 26.6 ± 15.8 vs. 14.4 ± 6.8, P < 0.001). Diagnostic confidence of the bSSFP DL images was superior for the evaluation of cardiovascular structures (e.g., atria and ventricles: P = 0.003). Conclusion: DL image denoising provides superior quality for DUS-gated fetal cardiac cine imaging of CHD compared to standard CS image reconstruction.

7.
Sci Rep ; 14(1): 497, 2024 01 04.
Article in English | MEDLINE | ID: mdl-38177651

ABSTRACT

Aim of this study was to assess the impact of virtual monoenergetic images (VMI) on dental implant artifacts in photon-counting detector computed tomography (PCD-CT) compared to standard reconstructed polychromatic images (PI). 30 scans with extensive (≥ 5 dental implants) dental implant-associated artifacts were retrospectively analyzed. Scans were acquired during clinical routine on a PCD-CT. VMI were reconstructed for 100-190 keV (10 keV steps) and compared to PI. Artifact extent and assessment of adjacent soft tissue were rated using a 5-point Likert grading scale for qualitative assessment. Quantitative assessment was performed using ROIs in most pronounced hypodense and hyperdense artifacts, artifact-impaired soft tissue, artifact-free fat and muscle tissue. A corrected attenuation was calculated as difference between artifact-impaired tissue and tissue without artifacts. Qualitative assessment of soft palate and cheeks improved for all VMI compared to PI (Median PI: 1 (Range: 1-3) and 1 (1-3); e.g. VMI130 keV 2 (1-5); p < 0.0001 and 2 (1-4); p < 0.0001). In quantitative assessment, VMI130 keV showed best results with a corrected attenuation closest to 0 (PI: 30.48 ± 98.16; VMI130 keV: - 0.55 ± 73.38; p = 0.0026). Overall, photon-counting deducted VMI reduce the extent of dental implant-associated artifacts. VMI of 130 keV showed best results and are recommended to support head and neck CT scans.


Subject(s)
Dental Implants , Artifacts , Retrospective Studies , Tomography, X-Ray Computed/methods , Cheek , Signal-To-Noise Ratio , Radiographic Image Interpretation, Computer-Assisted/methods
8.
Sci Rep ; 13(1): 22293, 2023 12 15.
Article in English | MEDLINE | ID: mdl-38102168

ABSTRACT

Prognosis estimation in patients with cardiogenic shock (CS) is important to guide clinical decision making. Aim of this study was to investigate the predictive value of opportunistic CT-derived body composition analysis in CS patients. Amount and density of fat and muscle tissue of 152 CS patients were quantified from single-slice CT images at the level of the intervertebral disc space L3/L4. Multivariable Cox regression and Kaplan-Meier survival analyses were performed to evaluate the predictive value of opportunistically CT-derived body composition parameters on the primary endpoint of 30-day mortality. Within the 30-day follow-up, 90/152 (59.2%) patients died. On multivariable analyses, lactate (Hazard Ratio 1.10 [95% Confidence Interval 1.04-1.17]; p = 0.002) and patient age (HR 1.04 [95% CI 1.01-1.07], p = 0.017) as clinical prognosticators, as well as visceral adipose tissue (VAT) area (HR 1.004 [95% CI 1.002-1.007]; p = 0.001) and skeletal muscle (SM) area (HR 0.987 [95% CI 0.975-0.999]; p = 0.043) as imaging biomarkers remained as independent predictors of 30-day mortality. Kaplan-Meier survival analyses showed significantly increased 30-day mortality in patients with higher VAT area (p = 0.015) and lower SM area (p = 0.035). CT-derived VAT and SM area are independent predictors of dismal outcomes in CS patients and have the potential to emerge as new imaging biomarkers available from routine diagnostic CT.


Subject(s)
Muscle, Skeletal , Shock, Cardiogenic , Humans , Shock, Cardiogenic/diagnostic imaging , Muscle, Skeletal/diagnostic imaging , Body Composition , Prognosis , Biomarkers , Tomography, X-Ray Computed/methods , Retrospective Studies
9.
Radiology ; 308(3): e230427, 2023 09.
Article in English | MEDLINE | ID: mdl-37750774

ABSTRACT

Background Deep learning (DL) reconstructions can enhance image quality while decreasing MRI acquisition time. However, DL reconstruction methods combined with compressed sensing for prostate MRI have not been well studied. Purpose To use an industry-developed DL algorithm to reconstruct low-resolution T2-weighted turbo spin-echo (TSE) prostate MRI scans and compare these with standard sequences. Materials and Methods In this prospective study, participants with suspected prostate cancer underwent prostate MRI with a Cartesian standard-resolution T2-weighted TSE sequence (T2C) and non-Cartesian standard-resolution T2-weighted TSE sequence (T2NC) between August and November 2022. Additionally, a low-resolution Cartesian DL-reconstructed T2-weighted TSE sequence (T2DL) with compressed sensing DL denoising and resolution upscaling reconstruction was acquired. Image sharpness was assessed qualitatively by two readers using a five-point Likert scale (from 1 = nondiagnostic to 5 = excellent) and quantitatively by calculating edge rise distance. The Friedman test and one-way analysis of variance with post hoc Bonferroni and Tukey tests, respectively, were used for group comparisons. Prostate Imaging Reporting and Data System (PI-RADS) score agreement between sequences was compared by using Cohen κ. Results This study included 109 male participants (mean age, 68 years ± 8 [SD]). Acquisition time of T2DL was 36% and 29% lower compared with that of T2C and T2NC (mean duration, 164 seconds ± 20 vs 257 seconds ± 32 and 230 seconds ± 28; P < .001 for both). T2DL showed improved image sharpness compared with standard sequences using both qualitative (median score, 5 [IQR, 4-5] vs 4 [IQR, 3-4] for T2C and 4 [IQR, 3-4] for T2NC; P < .001 for both) and quantitative (mean edge rise distance, 0.75 mm ± 0.39 vs 1.15 mm ± 0.68 for T2C and 0.98 mm ± 0.65 for T2NC; P < .001 and P = .01) methods. PI-RADS score agreement between T2NC and T2DL was excellent (κ range, 0.92-0.94 [95% CI: 0.87, 0.98]). Conclusion DL reconstruction of low-resolution T2-weighted TSE sequences enabled accelerated acquisition times and improved image quality compared with standard acquisitions while showing excellent agreement with conventional sequences for PI-RADS ratings. Clinical trial registration no. NCT05820113 © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Turkbey in this issue.


Subject(s)
Deep Learning , Prostatic Neoplasms , Humans , Male , Aged , Magnetic Resonance Imaging , Prospective Studies , Prostate/diagnostic imaging , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/surgery
10.
Sci Rep ; 13(1): 8955, 2023 06 02.
Article in English | MEDLINE | ID: mdl-37268675

ABSTRACT

Aim of this study was to assess the impact of virtual monoenergetic images (VMI) in combination and comparison with iterative metal artifact reduction (IMAR) on hip prosthesis-associated artifacts in photon-counting detector CT (PCD-CT). Retrospectively, 33 scans with hip prosthesis-associated artifacts acquired during clinical routine on a PCD-CT between 08/2022 and 09/2022 were analyzed. VMI were reconstructed for 100-190 keV with and without IMAR, and compared to polychromatic images. Qualitatively, artifact extent and assessment of adjacent soft tissue were rated by two radiologists using 5-point Likert items. Quantitative assessment was performed measuring attenuation and standard deviation in most pronounced hypodense and hyperdense artifacts, artifact-impaired bone, muscle, vessels, bladder and artifact-free corresponding tissue. To quantify artifacts, an adjusted attenuation was calculated as the difference between artifact-impaired tissue and corresponding tissue without artifacts. Qualitative assessment improved for all investigated image reconstructions compared to polychromatic images (PI). VMI100keV in combination with IMAR achieved best results (e.g. diagnostic quality of the bladder: median PI: 1.5 (range 1-4); VMI100keV+IMAR: 5 (3-5); p < 0.0001). In quantitative assessment VMI100keV with IMAR provided best artifact reduction with an adjusted attenuation closest to 0 (e.g. bone: PI: 302.78; VMI100keV+IMAR: 51.18; p < 0.0001). The combination of VMI and IMAR significantly reduces hip prosthesis-associated artifacts in PCD-CT and improves the diagnostic quality of surrounding tissue.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Retrospective Studies , Metals , Tomography, X-Ray Computed/methods , Artifacts , Algorithms
11.
J Am Heart Assoc ; 12(9): e029492, 2023 05 02.
Article in English | MEDLINE | ID: mdl-37119085

ABSTRACT

Background The objective of this study was to investigate cardiac abnormalities in intensive care unit (ICU) survivors of critical illness and to determine whether temporary acute kidney injury (AKI) is associated with more pronounced findings on cardiovascular magnetic resonance. Methods and Results There were 2175 patients treated in the ICU (from 2015 until 2021) due to critical illness who were screened for study eligibility. Post-ICU patients without known cardiac disease were prospectively recruited from March 2021 to May 2022. Participants underwent cardiovascular magnetic resonance including assessment of cardiac function, myocardial edema, late gadolinium enhancement, and mapping including extracellular volume fraction. Student t test, Mann-Whitney U test, and χ2 tests were used. There were 48 ICU survivors (46±15 years of age, 28 men, 29 with AKI and continuous kidney replacement therapy, and 19 without AKI) and 20 healthy controls who were included. ICU survivors had elevated markers of myocardial fibrosis (T1: 995±31 ms versus 957±21 ms, P<0.001; extracellular volume fraction: 24.9±2.5% versus 22.8±1.2%, P<0.001; late gadolinium enhancement: 1% [0%-3%] versus 0% [0%-0%], P<0.001), more frequent focal late gadolinium enhancement lesions (21% versus 0%, P=0.03), and an impaired left ventricular function (eg, ejection fraction: 57±6% versus 60±5%, P=0.03; systolic longitudinal strain: 20.3±3.7% versus 23.1±3.5%, P=0.004) compared with healthy controls. ICU survivors with AKI had higher myocardial T1 (1002±33 ms versus 983±21 ms; P=0.046) and extracellular volume fraction values (25.6±2.6% versus 23.9±1.9%; P=0.02) compared with participants without AKI. Conclusions ICU survivors of critical illness without previously diagnosed cardiac disease had distinct abnormalities on cardiovascular magnetic resonance including signs of myocardial fibrosis and systolic dysfunction. Findings were more abnormal in participants who experienced AKI with necessity of continuous kidney replacement therapy during their ICU stay. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT05034588.


Subject(s)
Acute Kidney Injury , Cardiomyopathies , Heart Defects, Congenital , Male , Humans , Adult , Contrast Media , Critical Illness , Gadolinium , Magnetic Resonance Imaging, Cine , Cardiomyopathies/diagnostic imaging , Cardiomyopathies/etiology , Cardiomyopathies/pathology , Fibrosis , Magnetic Resonance Spectroscopy , Survivors , Acute Kidney Injury/diagnosis , Acute Kidney Injury/etiology
12.
Eur J Radiol ; 163: 110831, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37059004

ABSTRACT

PURPOSE: To compare standard breath-hold (BH) cine imaging to a radial pseudo-golden-angle free-breathing (FB) technique in congenital heart disease (CHD). METHODS: In this prospective study, short-axis and 4-chamber BH and FB cardiac MRI sequences of 25 participants with CHD acquired at 1.5 Tesla, were quantitatively compared regarding ventricular volumes, function, interventricular septum thickness (IVSD), apparent signal to noise ratio (aSNR), and estimated contrast to noise ratio (eCNR). For qualitative comparison, three image quality criteria (contrast, endocardial edge definition, and artefacts) were rated on a 5-point Likert scale (5: excellent, 1: non-diagnostic). Paired t-Test was used for group comparisons, Bland-Altman analysis for agreement between techniques. Inter-reader agreement was compared using intraclass correlation coefficient. RESULTS: IVSD (BH 7.4 ± 2.1 mm vs FB 7.4 ± 1.9 mm, p =.71), biventricular ejection fraction (left ventricle [LV]: 56.4 ± 10.8% vs 56.1 ± 9.3%, p =.83; right ventricle [RV]: 49.5 ± 8.6% vs 49.7 ± 10.1%, p =.83), and biventricular end diastolic volume (LV: 176.3 ± 63.9 ml vs 173.9 ± 64.9 ml, p =.90; RV: 185.4 ± 63.8 ml vs 189.6 ± 66.6 ml, p =.34) were comparable. Mean measurement time for FB short-axis sequences was 8.1 ± 1.3 compared to 4.4 ± 1.3 min for BH (p <.001). Subjective image quality between sequences was deemed comparable, (4.6 ± 0.6 vs 4.5 ± 0.6, p =.26, for 4-chamber views) with a significant difference regarding short-axis views (4.9 ± 0.3 vs 4.5 ± 0.6, p =.008). aSNR was similar (BH 25.8 ± 11.2 vs FB 22.2 ± 9.5, p =.24), while eCNR was higher for BH (89.1 ± 36.1 vs 68.5 ± 32.1, p =.03). CONCLUSION: FB sequences yielded comparable results to BH regarding image quality, biventricular volumetry, and function, though measurement times were longer. The FB sequence described might be clinically valuable when BHs are insufficiently performed.


Subject(s)
Heart Defects, Congenital , Respiration , Humans , Prospective Studies , Magnetic Resonance Imaging/methods , Heart Defects, Congenital/diagnostic imaging , Magnetic Resonance Imaging, Cine/methods , Breath Holding , Reproducibility of Results
13.
Eur Radiol ; 33(8): 5498-5508, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36949253

ABSTRACT

OBJECTIVES: To find simple imaging-based features on cardiac magnetic resonance (CMR) that are associated with major adverse cardiovascular events (MACE) in takotsubo syndrome (TTS). METHODS: Patients with TTS referred for CMR between 2007 and 2021 were retrospectively evaluated. Besides standard CMR analysis, commonly known complications of TTS based on expert knowledge were assessed and summarised via a newly developed PE2RT score (one point each for pleural effusion, pericardial effusion, right ventricular involvement, and ventricular thrombus). Clinical follow-up data was reviewed up to three years after discharge. The relationship between PE2RT features and the occurrence of MACE (cardiovascular death or new hospitalisation due to acute myocardial injury, arrhythmia, or chronic heart failure) was examined using Cox regression analysis and Kaplan-Meier estimator. RESULTS: Seventy-nine patients (mean age, 68 ± 14 years; 72 women) with TTS were included. CMR was performed in a median of 4 days (IQR, 2-6) after symptom onset. Over a median follow-up of 13.3 months (IQR, 0.4-36.0), MACE occurred in 14/79 (18%) patients: re-hospitalisation due to acute symptoms (9/79, 11%) or chronic heart failure symptoms (4/79, 5%), and cardiac death (1/79, 1%). Patients with MACE had a higher PE2RT score (median [IQR], 2 [2-3] vs 1 [0-1]; p < 0.001). PE2RT score was associated with MACE on Cox regression analysis (hazard ratio per PE2RT feature, 2.44; 95%CI: 1.62-3.68; p < 0.001). Two or more PE2RT complications were strongly associated with the occurrence of MACE (log-rank p < 0.001). CONCLUSIONS: The introduced PE2RT complication score might enable an easy-to-assess outcome evaluation of TTS patients by CMR. KEY POINTS: • Complications like pericardial effusion, pleural effusion, right ventricular involvement, and ventricular thrombus (summarised as PE2RT features) are relatively common in takotsubo syndrome. • The proposed PE2RT score (one point per complication) was associated with the occurrence of major adverse cardiac events on follow-up. • Complications easily detected by cardiac magnetic resonance imaging can help clinicians derive long-term prognostic information on patients with takotsubo syndrome.


Subject(s)
Heart Failure , Takotsubo Cardiomyopathy , Thrombosis , Humans , Female , Middle Aged , Aged , Aged, 80 and over , Takotsubo Cardiomyopathy/diagnostic imaging , Ventricular Function, Left , Retrospective Studies , Magnetic Resonance Imaging/adverse effects , Prognosis , Heart Failure/diagnostic imaging , Heart Failure/etiology , Magnetic Resonance Spectroscopy , Magnetic Resonance Imaging, Cine/adverse effects , Predictive Value of Tests , Risk Factors
14.
Radiol Cardiothorac Imaging ; 5(1): e220129, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36860838

ABSTRACT

Purpose: To apply Doppler US (DUS)-gated fetal cardiac cine MRI in clinical routine and investigate diagnostic performance in complex congenital heart disease (CHD) compared with that of fetal echocardiography. Materials and Methods: In this prospective study (May 2021 to March 2022), women with fetuses with CHD underwent fetal echocardiography and DUS-gated fetal cardiac MRI on the same day. For MRI, balanced steady-state free precession cine images were acquired in the axial and optional sagittal and/or coronal orientations. Overall image quality was assessed on a four-point Likert scale (from 1 = nondiagnostic to 4 = good image quality). The presence of abnormalities in 20 fetal cardiovascular features was independently assessed by using both modalities. The reference standard was postnatal examination results. Differences in sensitivities and specificities were determined by using a random-effects model. Results: The study included 23 participants (mean age, 32 years ± 5 [SD]; mean gestational age, 36 weeks ± 1). Fetal cardiac MRI was completed in all participants. The median overall image quality of DUS-gated cine images was 3 (IQR, 2.5-4). In 21 of 23 participants (91%), underlying CHD was correctly assessed by using fetal cardiac MRI. In one case, the correct diagnosis was made by using MRI only (situs inversus and congenitally corrected transposition of the great arteries). Sensitivities (91.8% [95% CI: 85.7, 95.1] vs 93.6% [95% CI: 88.8, 96.2]; P = .53) and specificities (99.9% [95% CI: 99.2, 100] vs 99.9% [95% CI: 99.5, 100]; P > .99) for the detection of abnormal cardiovascular features were comparable between MRI and echocardiography, respectively. Conclusion: Using DUS-gated fetal cine cardiac MRI resulted in performance comparable with that of using fetal echocardiography for diagnosing complex fetal CHD.Keywords: Pediatrics, MR-Fetal (Fetal MRI), Cardiac, Heart, Congenital, Fetal Imaging, Cardiac MRI, Prenatal, Congenital Heart DiseaseClinical trial registration no. NCT05066399 Supplemental material is available for this article. © RSNA, 2023See also the commentary by Biko and Fogel in this issue.

15.
BMC Neurol ; 23(1): 86, 2023 Feb 28.
Article in English | MEDLINE | ID: mdl-36855093

ABSTRACT

BACKGROUND: Outcome assessment in stroke patients is essential for evidence-based stroke care planning. Computed tomography (CT) is the mainstay of diagnosis in acute stroke. This study aimed to investigate whether CT-derived cervical fat-free muscle fraction (FFMF) as a biomarker of muscle quality is associated with outcome parameters after acute ischemic stroke. METHODS: In this retrospective study, 66 patients (mean age: 76 ± 13 years, 30 female) with acute ischemic stroke in the anterior circulation who underwent CT, including CT-angiography, and endovascular mechanical thrombectomy of the middle cerebral artery between August 2016 and January 2020 were identified. Based on densitometric thresholds, cervical paraspinal muscles covered on CT-angiography were separated into areas of fatty and lean muscle and FFMF was calculated. The study cohort was binarized based on median FFMF (cutoff value: < 71.6%) to compare clinical variables and outcome data between two groups. Unpaired t test and Mann-Whitney U test were used for statistical analysis. RESULTS: National Institute of Health Stroke Scale (NIHSS) (12.2 ± 4.4 vs. 13.6 ± 4.5, P = 0.297) and modified Rankin scale (mRS) (4.3 ± 0.9 vs. 4.4 ± 0.9, P = 0.475) at admission, and pre-stroke mRS (1 ± 1.3 vs. 0.9 ± 1.4, P = 0.489) were similar between groups with high and low FFMF. NIHSS and mRS at discharge were significantly better in patients with high FFMF compared to patients with low FFMF (NIHSS: 4.5 ± 4.4 vs. 9.5 ± 6.7; P = 0.004 and mRS: 2.9 ± 2.1 vs.3.9 ± 1.8; P = 0.049). 90-day mRS was significantly better in patients with high FFMF compared to patients with low FFMF (3.3 ± 2.2 vs. 4.3 ± 1.9, P = 0.045). CONCLUSION: Cervical FFMF obtained from routine clinical CT might be a new imaging-based muscle quality biomarker for outcome prediction in stroke patients.


Subject(s)
Ischemic Stroke , Stroke , Humans , Female , Middle Aged , Aged , Aged, 80 and over , Pilot Projects , Retrospective Studies , Tomography, X-Ray Computed , Muscles , Stroke/diagnostic imaging
16.
Cardiovasc Intervent Radiol ; 46(5): 658-663, 2023 May.
Article in English | MEDLINE | ID: mdl-36826490

ABSTRACT

PURPOSE: To investigate and compare the physical properties of the new generation Gore VIATORR-Controlled Expansion Endoprosthesis (VCX) to those of the predecessor VIATORR stent in an in vitro experimental setup. MATERIALS AND METHODS: A total of 12 stents (8 VCX; 4 VIATORR; GORE, USA) were examined. Radial resistive force (RRF) and chronic outward force (COF) were assessed using a radial force testing machine (RX-650, Machine Solutions Inc., USA). To assess the radial forces of the VCX above 8 mm, balloon expansion was performed between cycles. RESULTS: All VCX stents show an abrupt decrease in COF at an external diameter of 8.3 mm; RRF decreases likewise at an external diameter of 8.5 mm. The predecessor VIATORR stent without the "controlled expansion" feature shows linear radial force reduction until full expansion at a diameter of 10 mm. The physical properties of the VCX can be altered by balloon modulation. Point of COF (RRF) reduction shifts to 8.5 mm (8.6 mm), 8.6 mm (8.8 mm) and 9.3 mm (9.6 mm) following modulation with a 8 mm, 9 mm and 10 mm balloon. CONCLUSIONS: The VCX shows an abrupt and disproportionate decrease in COF and RRF at an external diameter of 8.3 mm, thus passive expansion to its nominal diameter of 10 mm is not to be expected. By means of balloon dilatation the physical properties of the stent can be altered, enabling customized TIPS creation. The previous VIATORR stent shows continuous COF and RRF until total expansion.


Subject(s)
Portasystemic Shunt, Transjugular Intrahepatic , Humans , Stents , Prosthesis Design
17.
J Cardiovasc Comput Tomogr ; 17(2): 96-104, 2023.
Article in English | MEDLINE | ID: mdl-36792478

ABSTRACT

BACKGROUND: We aimed to comprehensively assess tricuspid valve anatomy and to determine factors associated with the more advanced stages beyond severe TR (i.e., massive to torrential). METHODS: We retrospectively analyzed the pre-procedural cardiac CT images in patients with ≥severe TR using 3mensio software. The tricuspid valve annulus size, right-atrial and right-ventricular dimensions, tenting height, and leaflet angles were measured. RESULTS: A total of 103 patients were analyzed. The mean effective regurgitant orifice area was 61.7 â€‹± â€‹31.5 â€‹mm2, vena contracta was 13.1 â€‹± â€‹4.6 â€‹mm, and massive/torrential TR was observed in 62 patients. Compared to patients with severe TR, patients with massive/torrential TR had a larger tricuspid annulus area (18.6 â€‹± â€‹3.4 â€‹cm2 vs. 20.6 â€‹± â€‹5.3 â€‹cm2, p â€‹= â€‹0.037), right atrial short-axis diameter (66.1 â€‹± â€‹9.1 â€‹mm vs. 70.6 â€‹± â€‹9.9 â€‹mm, p â€‹= â€‹0.022), increased tenting height (8.8 â€‹± â€‹3.6 â€‹mm vs. 10.7 â€‹± â€‹3.7 â€‹mm, p â€‹= â€‹0.014), and greater leaflet angles (anterior leaflet: 22 â€‹± â€‹9° vs. 32 â€‹± â€‹13°, p â€‹< â€‹0.001; posterior leaflet: 22 â€‹± â€‹11° vs. 30 â€‹± â€‹11°, p â€‹= â€‹0.003). In the multivariable logistic regression model, the angle of anterior leaflet (OR 1.08, 95%CI 1.03-1.14, p â€‹= â€‹0.004) and posterior leaflet (OR 1.07, 95%CI 1.02-1.13, p â€‹= â€‹0.007) were associated with massive/torrential TR. Additionally, patients with massive/torrential TR more often had TR jets from non-central/non-anteroseptal commissure (34% vs. 76%, p â€‹< â€‹0.001). In the multivariable model, a greater angle of the leaflets and a more elliptical annulus were associated with non-central/non-anteroseptal TR jets. CONCLUSIONS: Anterior and posterior leaflet angles are significant factors associated with massive/torrential TR. Furthermore, leaflet angles and ellipticity of the tricuspid valve are associated with the location of TR jets.


Subject(s)
Atrial Fibrillation , Tricuspid Valve Insufficiency , Humans , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve/diagnostic imaging , Retrospective Studies , Predictive Value of Tests , Tomography, X-Ray Computed
18.
Invest Radiol ; 58(3): 209-215, 2023 03 01.
Article in English | MEDLINE | ID: mdl-36070533

ABSTRACT

OBJECTIVES: The aim of this study was to compare a new compressed sensing (CS) method for T2-weighted propeller acquisitions (T2 CS ) with conventional T2-weighted propeller sequences (T2 conv ) in terms of achieving a higher image quality, while reducing the acquisition time. MATERIALS AND METHODS: Male participants with a clinical suspicion of prostate cancer were prospectively enrolled and underwent prostate magnetic resonance imaging at 3 T. Axial and sagittal images of the T2 conv sequence and the T2 CS sequence were acquired. Sequences were qualitatively assessed by 2 blinded radiologists concerning artifacts, image-sharpness, lesion conspicuity, capsule delineation, and overall image quality using 5-point Likert items ranging from 1 (nondiagnostic) to 5 (excellent). The apparent signal-to-noise ratio and apparent contrast-to-noise ratio were evaluated. PI-RADS scores were assessed for both sequences. Statistical analysis was performed by using Wilcoxon signed rank test and paired samples t test. Intrarater and interrater reliability of qualitative image evaluation was assessed using intraclass correlation coefficient (ICC) estimates. RESULTS: A total of 29 male participants were included (mean age, 66 ± 8 years). The acquisition time of the T2 CS sequence was respectively 26% (axial plane) and 24% (sagittal plane) shorter compared with the T2 conv sequence (eg, axial: 171 vs 232 seconds; P < 0.001). In the axial plane, the T2 CS sequence had fewer artifacts (4 [4-4.5] vs 4 [3-4]; P < 0.001), better image-sharpness (4 [4-4.5] vs 3 [3-3.5]; P < 0.001), better capsule delineation (4 [3-4] vs 3 [3-3.5]; P < 0.001), and better overall image quality (4 [4-4] vs 4 [3-4]; P < 0.001) compared with the T2 conv sequence. The ratings of lesion conspicuity were similar (4 [4-4] vs 4 [3-4]; P = 0.166). In the sagittal plane, the T2 CS sequence outperformed the T2 conv sequence in the categories artifacts (4 [4-4] vs 3 [3-4]; P < 0.001), image sharpness (4 [4-5] vs 4 [3-4]; P < 0.001), lesion conspicuity (4 [4-4] vs 4 [3-4]; P = 0.002), and overall image quality (4 [4-4] vs 4 [3-4]; P = 0.002). Capsule delineation was similar between both sequences (3 [3-4] vs 3 [3-3]; P = 0.07). Intraobserver and interobserver reliability for qualitative scoring were good (ICC intra: 0.92; ICC inter: 0.86). Quantitative analysis revealed a higher apparent signal-to-noise ratio (eg, axial: 52.2 ± 9.7 vs 22.8 ± 3.6; P < 0.001) and a higher apparent contrast-to-noise ratio (eg, axial: 44.0 ± 9.6 vs 18.6 ± 3.7; P ≤ 0.001) of the T2 CS sequence. PI-RADS scores were the same for both sequences in all participants. CONCLUSIONS: CS-accelerated T2-weighted propeller acquisition had a superior image quality compared with conventional T2-weighted propeller sequences while significantly reducing the acquisition time.


Subject(s)
Magnetic Resonance Imaging , Prostatic Neoplasms , Humans , Male , Middle Aged , Aged , Magnetic Resonance Imaging/methods , Prostate/diagnostic imaging , Reproducibility of Results , Prostatic Neoplasms/diagnostic imaging , Signal-To-Noise Ratio , Artifacts
19.
Eur Heart J Cardiovasc Imaging ; 24(7): 949-960, 2023 06 21.
Article in English | MEDLINE | ID: mdl-36423215

ABSTRACT

AIMS: The exact role of portal hypertension in cirrhotic cardiomyopathy remains unclear, and it is uncertain whether cardiac abnormalities also occur in non-cirrhotic portal hypertension (NCPH). This magnetic resonance imaging (MRI) study aimed to evaluate the presence of subclinical myocardial dysfunction, oedema, and fibrosis in NCPH. METHODS AND RESULTS: In this prospective study (2018-2022), participants underwent multiparametric abdominal and cardiac MRI including assessment of cardiac function, myocardial oedema, late gadolinium enhancement (LGE), and abdominal and cardiac mapping [T1 and T2 relaxation times, extracellular volume fraction (ECV)]. A total of 111 participants were included [44 participants with NCPH (48 ± 15 years; 23 women), 47 cirrhotic controls, and 20 healthy controls]. The cirrhotic group was dichotomized (Child A vs. Child B/C). NCPH participants demonstrated a more hyperdynamic circulation compared with healthy controls (cardiac index: 3.7 ± 0.6 vs. 3.2 ± 0.8 L/min/m², P = 0.004; global longitudinal strain: -27.3 ± 4.6 vs. -24.6 ± 3.5%, P = 0.022). The extent of abnormalities indicating myocardial fibrosis and oedema in NCPH was comparable with Child A cirrhosis (e.g. LGE presence: 32 vs. 33 vs. 69%, P = 0.004; combined T1 and T2 elevations: 46 vs. 27 vs. 69%, P = 0.017; NCPH vs. Child A vs. Child B/C). Correlations between splenic T1 and myocardial T1 values were found (r = 0.41; P = 0.007). Splenic T1 values were associated with the presence of LGE (odds ratio, 1.010; 95% CI: 1.002, 1.019; P = 0.013). CONCLUSION: MRI parameters of myocardial fibrosis and oedema were altered in participants with NCPH to a similar extent as in compensated cirrhosis and were associated with splenic markers of portal hypertension, indicating specific portal hypertensive cardiomyopathy.


Subject(s)
Cardiomyopathies , Hypertension, Portal , Child , Humans , Female , Contrast Media , Prospective Studies , Gadolinium , Cardiomyopathies/diagnostic imaging , Cardiomyopathies/etiology , Fibrosis , Magnetic Resonance Imaging/methods , Myocardium/pathology , Edema/diagnostic imaging , Edema/etiology , Edema/pathology , Hypertension, Portal/diagnostic imaging , Hypertension, Portal/etiology , Hypertension, Portal/pathology , Magnetic Resonance Imaging, Cine , Predictive Value of Tests
20.
Acta Radiol ; 64(4): 1322-1330, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36128748

ABSTRACT

BACKGROUND: Complication rates in percutaneous transhepatic biliary drainage (PTBD) are non-uniform and vary considerably. In addition, the impact of peri-procedural risk factors is under-investigated. PURPOSE: To compare success and complication rates of PTBD in patients with and without accompanying technical risk factors. MATERIAL AND METHODS: A single-center retrospective study was conducted from January 2004 to December 2016. Patients receiving PTBD due to biliary obstruction or biliary leakage were included. Technical risk factors (non-distended bile ducts, ascites, obesity, anasarca, non-compliance) were assessed. Complications were classified according to the Society of Interventional Radiology. RESULTS: In total, 372 patients were included (57.3% men, 42.7% women; mean age = 66 years). Overall, 466 PTBDs were performed. Of the patients, 70.1% presented with malignancy and biliary obstruction; 26.8% had benign biliary obstruction; 3.1% had biliary leakage. Technical risk factors were reported in 57 (15.3%) patients. Overall technical success of initial PTBD was 98.7%, primary technical success was 97.9%. In patients with non-dilatated bile ducts, primary technical success was 68.2%. Overall complication rate was 15.0% (8.1% major complications, 6.9% minor complications). Neither major nor minor complications were more frequent in patients with technical risk factors (P > 0.05). In left-sided PTBD, hemorrhage was more frequent (P = 0.015). Patients with malignancy were significantly more affected by drainage-related complications (P = 0.004; odds ratio = 2.03). The mortality rate was 0.5% (n = 2). CONCLUSION: PTBD is a safe and effective method for the treatment of biliary obstruction and biliary leaks. Complication rates are low, even in procedures with risk factors.


Subject(s)
Bile Ducts , Cholestasis , Male , Humans , Female , Aged , Retrospective Studies , Cholestasis/diagnostic imaging , Cholestasis/surgery , Drainage , Treatment Outcome
SELECTION OF CITATIONS