Ultrasonics ; 142: 107371, 2024 Jun 04.
Article in English | MEDLINE | ID: mdl-38852549

ABSTRACT

High Intensity Focused Ultrasound (HIFU) is used in clinical practice for thermal ablation of malignant and benign solid tumors located in various organs. One of the reason limiting the wider use of this technology is the long treatment time resulting from i.a. the large difference between the size of the focal volume of the heating beam and the size of the tumor. Therefore, the treatment of large tumors requires scanning their volume with a sequence of single heating beams, the focus of which is moved in the focal plane along a specific trajectory with specific time and distance interval between sonications. To avoid an undesirable increase in the temperature of healthy tissues surrounding the tumor during scanning, the acoustic power and exposure time of each HIFU beam as well as the time intervals between sonications should be selected in such a way as to cover the entire volume of the tumor with necrosis as quickly as possible. This would reduce the costs of treatment. The aim of this study was to quantitatively evaluate the hypothesis that selecting the average acoustic power and exposure time for each individual heating beam, as well as the temporal intervals between sonications, can significantly shorten treatment time. Using 3D numerical simulations, the dependence of the duration of treatment of a tumor with a diameter of 5 mm or 9 mm (requiring multiple exposure to the HIFU beam) on the sonication parameters (acoustic power, exposure time) of each single beam capable of delivering the threshold thermal dose (CEM43 = 240 min) to the treated tissue volume was examined. The treatment duration was determined as the sum of exposure times to individual beams and time intervals between sonications. The tumor was located inside the ex vivo tissue sample at a depth of 12.6 mm. The thickness of the water layer between the HIFU transducer and the tissue was 50 mm. The sonication and scanning parameters selected using the developed algorithm shortened the duration of the ablation procedure by almost 14 times for a 5-mm tumor and 20 times for a 9-mm tumor compared to the duration of the same ablation plan when a HIFU beam was used of a constant acoustic power, constant exposure time (3 s) and constant long time intervals (120 s) between sonications. Results of calculations of the location and size of the necrotic lesion formed were experimentally verified on ex vivo pork loin samples, showing good agreement between them. In this way, it was proven that the proper selection of sonication and scanning parameters for each HIFU beam allows to significantly shorten the time of HIFU therapy.

2.
Cancers (Basel) ; 14(1)2021 Dec 28.
Article in English | MEDLINE | ID: mdl-35008296

ABSTRACT

Uveal melanoma is the most common intraocular malignancy and arises from melanocytes in the choroid, ciliary body, or iris. The current eye-sparing treatment options include surgical treatment, plaque brachytherapy, proton beam radiotherapy, stereotactic photon radiotherapy, or photodynamic therapy. However, the efficacy of these methods is still unsatisfactory. This article reviews several possible new treatment options and their potential advantages in treating localized uveal melanoma. These methods may be based on the physical destruction of the cancerous cells by applying ultrasounds. Two examples of such an approach are High-Intensity Focused Ultrasound (HIFU)-a promising technology of thermal destruction of solid tumors located deep under the skin and sonodynamic therapy (SDT) that induces reactive oxygen species. Another approach may be based on improving the penetration of anti-cancer agents into UM cells. The most promising technologies from this group are based on enhancing drug delivery by applying electric current. One such approach is called transcorneal iontophoresis and has already been shown to increase the local concentration of several different therapeutics. Another technique, electrically enhanced chemotherapy, may promote drug delivery from the intercellular space to cells. Finally, new advanced nanoparticles are developed to combine diagnostic imaging and therapy (i.e., theranostics). However, these methods are mostly at an early stage of development. More advanced and targeted preclinical studies and clinical trials would be needed to introduce some of these techniques to routine clinical practice.

3.
Cells ; 8(11)2019 11 13.
Article in English | MEDLINE | ID: mdl-31766152

ABSTRACT

Malignant glial tumors (gliomas) are the second (after cerebral stroke) cause of death from diseases of the central nervous system. The current routine therapy, involving a combination of tumor resection, radio-, and chemo-therapy, only modestly improves survival. Sonodynamic therapy (SDT) has been broadly defined as a synergistic effect of sonication applied in combination with substances referred to as "sonosensitizers". The current review focuses on the possibility of the use of tumor-seeking sonosensitizers, in particular 5-aminolevulinic acid, to control recurring gliomas. In this application, SDT employs a principle similar to that of the more widely-known photodynamic therapy of superficially located cancers, the difference being the use of ultrasound instead of light to deliver the energy necessary to eliminate the sensitized malignant cells. The ability of ultrasound to penetrate brain tissues makes it possible to reach deeply localized intracranial tumors such as gliomas. The major potential advantage of this variant of SDT is its relative non-invasiveness and possibility of repeated application. Until now, there have been no clinical data regarding the efficacy and safety of such treatment for malignant gliomas, but the preclinical data are encouraging.


Subject(s)
Glioma/therapy , Ultrasonic Therapy/methods , Aminolevulinic Acid , Animals , Diagnostic Imaging , Disease Models, Animal , Glioma/diagnosis , Glioma/mortality , Humans , Light , Protoporphyrins , Ultrasonic Therapy/adverse effects , Ultrasonic Waves
4.
Ultrasonics ; 77: 203-213, 2017 05.
Article in English | MEDLINE | ID: mdl-28254565

ABSTRACT

The purpose of this work was to determine the influence of standing waves and possible multiple reflections under the conditions often encountered in examining the effects of ultrasound exposure on the cell cultures in vitro. More specifically, the goal was to quantitatively ascertain the influence of ultrasound exposure under free field (FF) and standing waves (SW) and multiple reflections (MR) conditions (SWMR) on the biological endpoint (50% cell necrosis). Such information would help in designing the experiments, in which the geometry of the container with biological tissue may prevent FF conditions to be established and in which the ultrasound generated temperature elevation is undesirable. This goal was accomplished by performing systematic, side-by-side experiments in vitro with C6 rat glioma cancer cells using 12 well and 96 well plates. It was determined that to obtain 50% of cell viability using the 12 well plates, the spatial average, temporal average (ISATA) intensities of 0.32W/cm2 and 5.89W/cm2 were needed under SWMR and FF conditions, respectively. For 96 well plates the results were 0.80W/cm2 and 2.86W/cm2 respectively. The corresponding, hydrophone measured pRMS maximum pressure amplitude values, were 0.71MPa, 0.75MPa, 0.75MPa and 0.73MPa, respectively. These results suggest that pRMS pressure amplitude was independent of the measurement set-up geometry and hence could be used to predict the cells' mortality threshold under any in vitro experimental conditions or even as a starting point for (pre-clinical) in vivo tests. The described procedure of the hydrophone measurements of the pRMS maximum pressure amplitude at the λ/2 distance (here 0.75mm) from the cell's level at the bottom of the dish or plate provides the guideline allowing the difference between the FF and SWMR conditions to be determined in any experimental setup. The outcome of the measurements also indicates that SWMR exposure might be useful at any ultrasound assisted therapy experiments as it permits to reduce thermal effects. Although the results presented are valid for the experimental conditions used in this study they can be generalized. The analysis developed provides methodology facilitating independent laboratories to determine their specific ultrasound exposure parameters for a given biological end-point under standing waves and multiple reflections conditions. The analysis also permits verification of the outcome of the experiments mimicking pre- and clinical environment between different, unaffiliated teams of researchers.


Subject(s)
Glioma/pathology , Ultrasonic Therapy/methods , Animals , Apoptosis , Cell Line, Tumor , Equipment Design , In Vitro Techniques , Pressure , Rats , Sonication , Temperature , Transducers , Tumor Cells, Cultured
5.
Ultrasonics ; 76: 92-98, 2017 04.
Article in English | MEDLINE | ID: mdl-28086110

ABSTRACT

A technique using pulsed High Intensity Focused Ultrasound (HIFU) to destroy deep-seated solid tumors is a promising noninvasive therapeutic approach. A main purpose of this study was to design and test a HIFU transducer suitable for preclinical studies of efficacy of tested, anti-cancer drugs, activated by HIFU beams, in the treatment of a variety of solid tumors implanted to various organs of small animals at the depth of the order of 1-2cm under the skin. To allow focusing of the beam, generated by such transducer, within treated tissue at different depths, a spherical, 2-MHz, 29-mm diameter annular phased array transducer was designed and built. To prove its potential for preclinical studies on small animals, multiple thermal lesions were induced in a pork loin ex vivo by heating beams of the same: 6W, or 12W, or 18W acoustic power and 25mm, 30mm, and 35mm focal lengths. Time delay for each annulus was controlled electronically to provide beam focusing within tissue at the depths of 10mm, 15mm, and 20mm. The exposure time required to induce local necrosis was determined at different depths using thermocouples. Location and extent of thermal lesions determined from numerical simulations were compared with those measured using ultrasound and magnetic resonance imaging techniques and verified by a digital caliper after cutting the tested tissue samples. Quantitative analysis of the results showed that the location and extent of necrotic lesions on the magnetic resonance images are consistent with those predicted numerically and measured by caliper. The edges of lesions were clearly outlined although on ultrasound images they were fuzzy. This allows to conclude that the use of the transducer designed offers an effective noninvasive tool not only to induce local necrotic lesions within treated tissue without damaging the surrounding tissue structures but also to test various chemotherapeutics activated by the HIFU beams in preclinical studies on small animals.


Subject(s)
Antineoplastic Agents/pharmacology , High-Intensity Focused Ultrasound Ablation/instrumentation , Transducers , Animals , Equipment Design , Red Meat , Swine , Temperature
6.
Ultrasonics ; 65: 211-9, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26498063

ABSTRACT

In therapeutic applications of High Intensity Focused Ultrasound (HIFU) the guidance of the HIFU beam and especially its focal plane is of crucial importance. This guidance is needed to appropriately target the focal plane and hence the whole focal volume inside the tumor tissue prior to thermo-ablative treatment and beginning of tissue necrosis. This is currently done using Magnetic Resonance Imaging that is relatively expensive. In this study an ultrasound method, which calculates the variations of speed of sound in the locally heated tissue volume by analyzing the phase shifts of echo-signals received by an ultrasound scanner from this very volume is presented. To improve spatial resolution of B-mode imaging and minimize the uncertainty of temperature estimation the acoustic signals were transmitted and received by 8 MHz linear phased array employing Synthetic Transmit Aperture (STA) technique. Initially, the validity of the algorithm developed was verified experimentally in a tissue-mimicking phantom heated from 20.6 to 48.6 °C. Subsequently, the method was tested using a pork loin sample heated locally by a 2 MHz pulsed HIFU beam with focal intensity ISATA of 129 W/cm(2). The temperature calibration of 2D maps of changes in the sound velocity induced by heating was performed by comparison of the algorithm-determined changes in the sound velocity with the temperatures measured by thermocouples located in the heated tissue volume. The method developed enabled ultrasound temperature imaging of the heated tissue volume from the very inception of heating with the contrast-to-noise ratio of 3.5-12 dB in the temperature range 21-56 °C. Concurrently performed, conventional B-mode imaging revealed CNR close to zero dB until the temperature reached 50 °C causing necrosis. The data presented suggest that the proposed method could offer an alternative to MRI-guided temperature imaging for prediction of the location and extent of the thermal lesion prior to applying the final HIFU treatment.


Subject(s)
Body Temperature/physiology , High-Intensity Focused Ultrasound Ablation/methods , Muscle, Skeletal/diagnostic imaging , Muscle, Skeletal/physiology , Thermography/methods , Ultrasonography/methods , Animals , Body Temperature/radiation effects , Computer Simulation , High-Energy Shock Waves , Image Interpretation, Computer-Assisted/methods , In Vitro Techniques , Models, Biological , Muscle, Skeletal/radiation effects , Phantoms, Imaging , Reproducibility of Results , Scattering, Radiation , Sensitivity and Specificity , Swine
7.
PLoS One ; 9(4): e94929, 2014.
Article in English | MEDLINE | ID: mdl-24743838

ABSTRACT

A tissue thermal conductivity (Ks) is an important parameter which knowledge is essential whenever thermal fields induced in selected organs are predicted. The main objective of this study was to develop an alternative ultrasonic method for determining Ks of tissues in vitro suitable for living tissues. First, the method involves measuring of temperature-time T(t) rises induced in a tested tissue sample by a pulsed focused ultrasound with measured acoustic properties using thermocouples located on the acoustic beam axis. Measurements were performed for 20-cycle tone bursts with a 2 MHz frequency, 0.2 duty-cycle and 3 different initial pressures corresponding to average acoustic powers equal to 0.7 W, 1.4 W and 2.1 W generated from a circular focused transducer with a diameter of 15 mm and f-number of 1.7 in a two-layer system of media: water/beef liver. Measurement results allowed to determine position of maximum heating located inside the beef liver. It was found that this position is at the same axial distance from the source as the maximum peak-peak pressure calculated for each nonlinear beam produced in the two-layer system of media. Then, the method involves modeling of T(t) at the point of maximum heating and fitting it to the experimental data by adjusting Ks. The averaged value of Ks determined by the proposed method was found to be 0.5±0.02 W/(m·°C) being in good agreement with values determined by other methods. The proposed method is suitable for determining Ks of some animal tissues in vivo (for example a rat liver).


Subject(s)
Models, Theoretical , Ultrasonography/instrumentation , Ultrasonography/methods , Animals , Rats
8.
Ultrasonics ; 51(8): 997-1005, 2011 Dec.
Article in English | MEDLINE | ID: mdl-21722932

ABSTRACT

This work addresses the difficulties in the measurements of the nonlinear medium parameter B/A and presents a modification of the finite amplitude method (FAM), one of the accepted procedures to determine this parameter. The modification is based on iterative, hybrid approach and entails the use of the versatile and comprehensive model to predict distortion of the pressure-time waveform and its subsequent comparison with the one experimentally determined. The measured p-t waveform contained at least 18 harmonics generated by 2.25 MHz, 29 mm effective diameter, single element, focused PZT source (f-number 3.5) and was recorded by Sonora membrane hydrophone calibrated in the frequency range 1-40 MHz. The hydrophone was positioned coaxially at the distal end of the specially designed, two-section assembly comprising of one, fixed length (60mm), water-filled cylindrical container and the second, variable length (60-120 mm) container that was filled with unknown medium. The details of the measurement chamber are described and the reasons for this specific design are analyzed. The data were collected with the variable length chamber filled with 1.3-butanediol, which was used as a close approximation of tissue mimicking phantom. The results obtained provide evidence that a novel combination of the FAM with the semi-empirical nonlinear propagation model based on the hyperbolic operator is capable of reducing the overall uncertainty of the B/A measurements as compared to those reported in the literature. The overall uncertainty of the method reported here was determined to be ±2%, which enhances the confidence in the numerical values of B/A measured for different, clinically relevant media. Optimization of the approach is also discussed and it is shown that it involves an iterative procedure that entails a careful selection of the acoustic source and its geometry and the axial distance over which the measurements need to be performed. The optimization also depends critically on the experimental determination of the source surface pressure amplitude.


Subject(s)
Ultrasonics/methods , Acoustics , Algorithms , Butylene Glycols/chemistry , Calibration , Equipment Design , Nonlinear Dynamics , Phantoms, Imaging , Ultrasonics/instrumentation , Water/chemistry