Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 53
Filter
1.
Hernia ; 27(4): 943-956, 2023 08.
Article in English | MEDLINE | ID: mdl-37335520

ABSTRACT

PURPOSE: To determine the prevalence of rectus diastasis (RD) in patients with inguinal hernia. MATERIAL AND METHODS: Multicenter, cross-sectional study. Patients with inguinal hernia were included in the study group (IH) and those with benign proctologic complaints created the control group (CG). Age, gender, BMI, family history for inguinal hernias, comorbid diseases, alcohol use, smoking, constipation, malignancy, chemotherapy, number of births, multiple pregnancies and prostate hypertrophy history of all patients in both groups were recorded. All patients were evaluated for RD and umbilical hernias by physical examination. RESULTS: A total of 528 consecutive patients were included in the study (292 IH / 236 CG). Overall prevalence of RD was 35.6% and it was significantly higher in IH than in CG (46.9% vs 21.6%, p < 0.001). Also, umbilical hernia was more frequently detected in the patients with inguinal hernia. Other risk factors for RD were age, BMI, DM, BPH and smoking. The mean inter-rectus distance for 528 patients was 18.1 mm; it was 20.71 ± 10.68 mm in IH and 14.88 ± 8.82 in CG (p < 0.001). It was determined that the increase in age and BMI caused an increase in the inter-rectus distance, and that the presence of DM, inguinal hernia and umbilical hernia increased the inter-rectus distance quantitatively. CONCLUSIONS: The prevalence of RD seems to be higher in patients with inguinal hernia comparing to that in general population. Increased age, high BMI and DM were found to be independent risk factors for RD development.


Subject(s)
Hernia, Inguinal , Hernia, Umbilical , Male , Humans , Hernia, Inguinal/complications , Hernia, Inguinal/epidemiology , Hernia, Umbilical/complications , Hernia, Umbilical/epidemiology , Hernia, Umbilical/surgery , Prevalence , Cross-Sectional Studies , Herniorrhaphy/adverse effects
2.
Hernia ; 26(3): 769-778, 2022 06.
Article in English | MEDLINE | ID: mdl-35020092

ABSTRACT

AIM: To find out the current status of the internet use of patients who undergo surgery for repair of their hernias. MATERIALS AND METHODS: The patients who were diagnosed with abdominal wall hernia and scheduled for elective hernia repair were requested to answer a questionnaire. The questions were directed face-to-face by the surgeons themselves. The age, gender, education status, American Society of Anesthesiologists (ASA) physical status, place of living, health insurance, access to the Internet, surgical method, the person who did the search, previous hernia surgery, recurrence of previous hernia surgery, surgery other than hernia, and the hernia type were the recorded parameters at the first stage. Then, the answers for three main questions were taken: "Did you make a search about your hernia?", "Did you make a search about your surgeon?", "Would you prefer another surgeon if you could?" RESULTS: A total of 200 patients were included in the study (146 male/54 female). 55.5% of the patients made an Internet search about their hernias. 58.5% of the patients made a search to find a proper surgeon. 12.5% of the patients stated that they would like to go to another surgeon for the hernia repair if it was possible. Internet search rate was significantly higher in younger patients in comparison with older patients. The higher the education level of the patients, the higher the rate of making Internet searches about the hernias and surgeons. Patients who live in the cities more frequently made Internet searches in comparison with those living in towns or villages. Internet searches about the hernias were similar in patients who had a history of hernia surgery (n = 23, 52%), and were even operated for recurrence of the same hernia (n = 30, 60%), compared to other patients (p = 0.569). Similarly, the rates of conducting surgeon research of the patients in these two groups (66.7%, 56.5%, respectively) were statistically similar (p = 0.450). The effect of ASA classification of patients on the Internet researches conducted about the disease and about the surgeons was not statistically significant (p = 0.799, p = 0.388, respectively). It was found that the rates of researching about the disease and about the surgeon on the Internet were significantly higher in patients who had undergone a minimally invasive surgery (p < 0.001, p < 0.001, respectively). CONCLUSIONS: Less than two-thirds of the hernia patients make Internet search about their disease. Higher education level, younger age, patient's preference for minimally invasive surgery and living in a city positively affect Internet search rates.


Subject(s)
Hernia, Inguinal , Hernia, Ventral , Surgeons , Female , Hernia, Inguinal/etiology , Hernia, Inguinal/surgery , Hernia, Ventral/surgery , Herniorrhaphy/methods , Humans , Internet , Male
3.
Hernia ; 25(5): 1231-1238, 2021 10.
Article in English | MEDLINE | ID: mdl-33904998

ABSTRACT

PURPOSE: This study aimed to determine whether crossing of the mesh's lateral tails is beneficial in Lichtenstein repairs for medial (direct) inguinal hernias. METHODS: We allocated 116 patients with unilateral medial (direct) inguinal hernias into two groups: mesh tail crossing (group C) or no mesh tail crossing (group N). In group C, the lateral tails were sutured together at the inguinal ligament, whereas the lateral tails were sutured in a parallel position in group N. Visual analog scale (VAS) scores were postoperatively recorded in person at the 1st, 7th, 30th, and 90th days and at the 1st year. The Short-Form Health Survey (SF-36) scores were calculated postoperatively at one month and one year. Examinations to detect hernia recurrence were performed at the end of the 1st year. Follow-ups at the 5th year were performed via phone calls to obtain the Sheffield pain scale and VAS values and to determine the possibility of hernia recurrence. RESULTS: VAS and SF-36 scores at the 1st, 7th, 30th, and 90th days and 1st year were all higher in group C than in group N. In group C, one patient experienced moderate pain, and one experienced severe pain. In the 5th year, VAS and Sheffield pain scores were significantly higher in group C than in group N. CONCLUSIONS: During Lichtenstein repair for medial (direct) inguinal hernias, crossing of the mesh tails may increase the frequency of postoperative chronic inguinal pain.


Subject(s)
Chronic Pain , Hernia, Inguinal , Chronic Pain/epidemiology , Chronic Pain/etiology , Hernia, Inguinal/surgery , Herniorrhaphy/adverse effects , Humans , Pain, Postoperative/epidemiology , Pain, Postoperative/etiology , Recurrence , Surgical Mesh , Treatment Outcome
4.
Hernia ; 24(5): 985-993, 2020 10.
Article in English | MEDLINE | ID: mdl-32592152

ABSTRACT

PURPOSE: To determine the time to resumption of outdoor walking, car driving, sports, and sexual activity following elective inguinal hernia repair, and to reveal if there are differences between surgeons' recommendations and patients' real return times. METHODS: A questionnaire including questions about recommendations to hernia patients for times to resume outdoor walking ability without assistance, driving and sexual intercourse after an elective inguinal hernia repair was sent to surgeons. Also, a short questionnaire was sent to patients who had undergone elective inguinal hernia repair to search the exact times for resuming these physical activities. RESULTS: Surgeons' thoughts and recommendations to their patients varied significantly. The range of recommendations were same day to 20 days for outdoor walking, and same day to 3 months both for driving and sexual intercourse. Patients' actual resumption of postoperative activities were 1-14 days for outdoor walking, 1 day to 3 months for driving, and 1 day to 2 months for sexual intercourse. When the answers from the two questionnaires were compared, it was observed that the mean times for resumption of outdoor walking and sexual intercourse were significantly longer in the patients' lives than recommended by the surgeons. Patients ≥ 60 years were able to walk outside, drive, and participate in sexual activity earlier than the younger patients. Bilateral and recurrent hernia repairs caused slower resumption of different activities in comparison to primary hernias. CONCLUSIONS: Patients reported that times for resumption of outdoor walking, driving, and sexual activity were significantly longer than those recommended by surgeons. Age, BMI, bilateral repair, and recurrent hernias were found to be factors affecting return time to different activities.


Subject(s)
Automobile Driving , Hernia, Inguinal/surgery , Herniorrhaphy , Recovery of Function , Sexual Behavior , Walking , Adult , Aged , Elective Surgical Procedures , Female , Humans , Male , Middle Aged , Postoperative Period , Surveys and Questionnaires , Time Factors
6.
Hernia ; 23(6): 1229-1235, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31222460

ABSTRACT

PURPOSE: To conduct a study to determine the measurements of the inguinal region in male patients with inguinal hernias to reveal the proper mesh size for each patient. METHODS: In this prospective study, the anthropometric measurements were obtained from 100 consecutive adult male patients with unilateral primary inguinal hernias. First, the distance between the pubic tubercle and the medial border of the deep inguinal ring was measured (x). Second, the distance between the inner edge of the inguinal ligament and the uppermost level of the internal oblique aponeurosis at the midpoint of the inguinal ligament corresponding to the Hesselbach triangle was measured (y). Individual mesh sizes were calculated according to the original recommendations for mesh overlap. RESULTS: The mean x value was 41.6 mm (22-55 mm), the mean y value was 45.2 mm (30-68 mm). The mean dimensions of the mesh were 126.6 mm × 65.2 mm. The largest mesh was 140 mm × 88 mm, and the smallest one was 107 mm × 62 mm. The mean mesh area was 8320 mm2. It was larger than the index mesh area recommended by the Lichtenstein Hernia Institute in 45 patients and smaller in 55 patients. CONCLUSIONS: The intraoperative measurements for ideal mesh size in Lichtenstein repair of inguinal hernias may present somewhat different mesh dimensions in many patients. Individualization of mesh size may be of importance in surgical outcomes.


Subject(s)
Hernia, Inguinal/surgery , Herniorrhaphy/methods , Surgical Mesh , Adult , Aged , Aged, 80 and over , Body Weights and Measures/methods , Hernia, Inguinal/pathology , Humans , Intraoperative Period , Male , Middle Aged , Prospective Studies , Turkey , Young Adult
8.
Neth J Med ; 73(1): 17-22, 2015 Jan.
Article in English | MEDLINE | ID: mdl-26219937

ABSTRACT

BACKGROUND: The incidence and potential risk factors for the recurrence of benign nodular goitre after unilateral thyroidectomy are not clearly defined. The aim of this study was to assess the rate of progression of nodular goitre in the contralateral thyroid lobe and of hypothyroidism requiring replacement therapy after unilateral thyroid lobectomy for benign nodular goitre. PATIENTS AND METHODS: Patients who underwent hemithyroidectomy for benign nodular goitre between 2000 and 2009 were included in the study. The primary outcome of this study was the reoperation rate for recurrent goitre, the rate of progression of nodular goitre and the rate of hypothyroidism requiring L-T4 replacement therapy. Clinical factors that have an effect on progression were further analysed. RESULTS: 259 patients were included for study. Progression of the nodular goitre in the remnant lobe was observed in 32% (n = 83) of the patients. However, over time, only 2% of these 83 patients underwent contralateral hemithyroidectomy due to this progression. Fifty-six (22%) patients required L-thyroxin replacement due to persistent hypothyroidism after hemithyroidectomy. The factors shown to affect progression of nodular goitre were advanced age, preoperative hyperthyroidism, preoperative diagnosis of toxic nodular goitre and the presence of surgical indication for a toxic goitre causing hyperthyroidism and a definitive pathological diagnosis of nodular hyperplasia. CONCLUSION: There was a progression of the nodular goitre in the remnant lobe in about one-third of the patients who underwent hemithyroidectomy. However, only 2% of these patients underwent complementary contralateral hemithyroidectomy due to clinical progression in 31 months of follow-up.


Subject(s)
Disease Management , Goiter, Nodular/surgery , Thyroidectomy/methods , Female , Follow-Up Studies , Goiter, Nodular/diagnosis , Humans , Male , Middle Aged , Recurrence , Reoperation , Retrospective Studies , Risk Factors , Treatment Outcome
9.
Chirurgia (Bucur) ; 109(5): 613-9, 2014.
Article in English | MEDLINE | ID: mdl-25375046

ABSTRACT

AIM: To identify rates of recurrence and hypothyroidism after hemithyroidectomy for unilateral nodular thyroid diseases and its advantages over bilateral radical resections. METHODS: Fifty patients who underwent thyroid lobectomy with unilateral thyroid disease were included. Follow-up with thyroid function tests on the first month and then once every three months, as well as ultrasonography controls once a year were performed postoperatively. Recurrence, which was accepted asat least one nodule with a diameter of 5 mm on the remnant lobe, and the need for postoperative thyroxin therapy were analysed, along with the relation of both with preoperative medical therapy, histological results, numbers and diameters of thyroid nodules, follow-up duration. RESULTS: The incidence of recurrent disease after hemithyroidectomy was 12% after a mean follow-up time of 25.2 months (range, 10-43) while the incidence of clinical hypothyroidism which needs thyroxin therapy was 8%. Gender, age,substitutive and suppressive therapy before operation,histological evaluation, the presence of multiple nodules and diameter of nodules were predictive of neither recurrence nor post operative thyroxin therapy. CONCLUSION: Hemithyroidectomy for unilateral thyroid disease has a moderate rate of recurrence, low rates of hypothyroidism and rare postoperative complications, with short hospital stay.


Subject(s)
Thyroid Nodule/surgery , Thyroidectomy/methods , Adult , Aged , Female , Follow-Up Studies , Humans , Hypothyroidism/drug therapy , Hypothyroidism/epidemiology , Hypothyroidism/etiology , Male , Middle Aged , Risk Factors , Thyroid Function Tests , Thyroid Nodule/epidemiology , Thyroidectomy/adverse effects , Thyroidectomy/statistics & numerical data , Thyroxine/therapeutic use , Treatment Outcome , Turkey/epidemiology
10.
Chirurgia (Bucur) ; 109(1): 60-5, 2014.
Article in English | MEDLINE | ID: mdl-24524472

ABSTRACT

BACKGROUND AND AIM: Sutureless total thyroidectomy by using vessel sealing devices has been shown to be safe in some recent clinical studies. However, some surgeons are still concerned about the use of these energy devices in the vicinity of there current laryngeal nerve and parathyroid glands. The objective of this study was to investigate the effects of the use of pure LigaSure on postoperative complications and to discuss the pertinent literature. METHODS: A total of 456 patients having undergone a total thyroidectomy operation between June 2009 and March 2011 were included in the study. Data were prospectively collected and retrospectively evaluated. Patients were separated into 2 groups. Group L comprised of 182 patients where onlyLigaSure was used, and group LT consisted of 274 patients where ligation was used in the vicinity of the recurrent laryngeal nerve and parathyroid glands, and LigaSure was used in all other parts of the surgery. Patient's blood calcium values were checked preoperatively and at postoperative 24, 48, and 72 hours. Groups were assessed in terms of demographic properties, thyroid pathology, duration of operation, and postoperative complications. RESULTS: Groups were similar in respect of demographic properties, operation duration, thyroid gland pathology. No mortality rate was recorded. Laboratory hypocalcemia rate was higher in group L (P 0.003), but no significant difference was identified between groups in terms of symptomatic hypocalcemia.No permanent hypocalcemia or recurrent laryngeal nerve injury developed in any of the patients in the two groups. CONCLUSIONS: Pure LigaSure for total thyroidectomy may increase laboratory hypocalcemia rate, but not symptomatic hypocalcemia. Hemorrhage related complications were similar and low in the two groups. Ligations in the places close to delicate anatomic structures did not cause longer operative times and may be a safer option in total thyroidectomy.


Subject(s)
Blood Loss, Surgical/prevention & control , Hypocalcemia/prevention & control , Patient Safety , Thyroidectomy/methods , Adult , Aged , Aged, 80 and over , Female , Hemostasis, Surgical/methods , Humans , Hypocalcemia/blood , Ligation/methods , Male , Middle Aged , Prospective Studies , Retrospective Studies , Thyroid Diseases/surgery , Thyroidectomy/instrumentation , Treatment Outcome
11.
Chirurgia (Bucur) ; 108(6): 840-8, 2013.
Article in English | MEDLINE | ID: mdl-24331324

ABSTRACT

BACKGROUND AND AIM: Prosthetic mesh repair for abdominal wall hernias is widely used because of its technical simplicity and low hernia recurrence rates. The most commonly used material is pure polypropylene mesh, although newer composite materials are recommended by some centers due to their advantages.However, these meshes are more expensive than pure polypropylene meshes. Resterilization of a pure polypropylene mesh has been shown to be quite safe, and many centers prefer slicing a large mesh into smaller pieces, suitable for any hernia type or defect size. Nevertheless there is no data about the safety after resterilization of the composite meshes. The present study was carried out to investigate the effects of resterilization and in vitro degradation in phosphate buffered saline solution on the physical structure and the mechanical properties of partially absorbable lightweight meshes. METHODS: Two composite meshes were used in the study: One mesh consists of monofilament polypropylene and monofilament polyglecaprone -a copolymer of glycolide and epsilon(ε)- caprolactone - (Ultrapro®, 28 g m2, Ethicon, Hamburg,Germany), and the other one consisted of multifilament polypropylene and multifilament polyglactine (Vypro II®, 30g m2, Ethicon, Hamburg, Germany). Two large meshes were cut into rectangular specimens sized 50 x 20 mm for mechanical testing and 20 x 20 mm for in vitro degradation experiments.Meshes were divided into control group with no resterilization and gas resterilization. Ethylene oxide gas sterilization was performed at 55°C for 4.5 hours. In vitro degradation in 0.01M phosphate buffered saline (PBS, pH 7.4) solution at 37 ± 1°C for 8 weeks was applied to one subgroup in each mesh group. Tensiometric measurements and scanning electronmicroscopic evaluations were completed for control and resterilization specimens. RESULTS: Regardless of resterilization, when the meshes were exposed to in vitro degradation, all mechanical parameters decreased significantly. Highest reduction in mechanical properties was observed for Ultrapro due to the degradation of absorbable polyglecaprone and polyglactin parts of these meshes. It was observed that resterilization by ethylene oxide did not determine significant difference on the degradation characteristics and almost similar physical structures were observed for resterilized and non-resterilized meshes. For VyproII meshes, no significant mechanical difference was observed between resterilized and non-resterilized meshes after degradation while resterilized Ultrapro meshes exhibited stronger characteristics than non-resterilized counterparts, after degradation. CONCLUSION: Resterilization with ethylene oxide did not affect the mechanical properties of partially absorbable compositemeshes. No important surface changes were observed inscanning electron microscopy after resterilization.


Subject(s)
Disinfectants/pharmacology , Ethylene Oxide/pharmacology , Polypropylenes , Sterilization , Surgical Mesh , In Vitro Techniques , Materials Testing , Sterilization/methods , Tensile Strength
12.
Chirurgia (Bucur) ; 108(6): 807-11, 2013.
Article in English | MEDLINE | ID: mdl-24331318

ABSTRACT

BACKGROUND: Ventral incisional hernias are more commonly associated with comorbid diseases when compared to other hernia types. We investigate the hypothesis that unfavourable local factors related to comorbid diseases may lead to incisional hernia development. MATERIALS AND METHODS: The characteristics of incisional hernia (71 patients), primary ventral hernia (114 patients)and groin hernia groups (820 patients) were analysed and compared among each other. RESULTS: Advanced age, female gender, presence of coexisting disease, strangulation, incarceration, bowel or omentum resections, deep venous thrombosis, ileus, wound infections,ASA scores were significantly higher and the duration of hospital stay was longer in the incisional hernia group when compared to the other groups. Presence of coexisting diseases and ASA class scores were independent predictors of length of hospital stay in incisional hernia patients (p 0.05). CONCLUSIONS: Ventral incisional hernias are associated with higher incidence of comorbid diseases in comparison with other types of abdominal wall hernias. Patients with coexisting diseases might have unfavourable local factors that lead to incisional hernia development.


Subject(s)
Hernia, Ventral/epidemiology , Hernia, Ventral/surgery , Adult , Aged , Comorbidity , Female , Hernia, Inguinal/epidemiology , Hernia, Inguinal/surgery , Hernia, Ventral/etiology , Humans , Male , Middle Aged , Prospective Studies , Risk Assessment , Risk Factors , Treatment Outcome , Turkey/epidemiology
13.
J BUON ; 18(3): 708-12, 2013.
Article in English | MEDLINE | ID: mdl-24065487

ABSTRACT

PURPOSE: This study investigated the surgical gastrostomy and jejunostomy procedures in cancer patients who needed nutritional support and endoscopy was unattainable. METHODS: Operation time and procedure, anesthesia and tube types, procedure-specific and surgical complications, and tube replacement at the follow up period were retrospectively analyzed. RESULTS: 109 patients (44 female, 65 male, mean age 50.9 years, range 14-87) were subjected to surgical gastrostomy/ jejunostomy. Ninety-three (85.4%) patients had head-neck and gastrointestinal cancers. In 94 (86.2%) patients endoscopy was impossible due to obstruction of the esophagus and stomach. Gastrostomy/jejunostomy was combined with other surgical procedures in 12 (11 %) patients. Procedure- related complications occurred in 22 (20.7%) patients. Early 30-day mortality occurred in 12 (11 %) cases. The median follow up period was 3.6 months (range 0-18). CONCLUSION: Obstructing cancer, obesity or previous laparotomy make the use of endoscopic techniques impossible. For these patients, surgical gastrostomy/jejunostomy is safe with acceptable complication rates and improves the treatment outcomes with nutritional support.


Subject(s)
Gastrointestinal Neoplasms/surgery , Gastrostomy , Head and Neck Neoplasms/surgery , Jejunostomy , Postoperative Complications , Adolescent , Adult , Aged , Aged, 80 and over , Endoscopy , Female , Follow-Up Studies , Gastrointestinal Neoplasms/complications , Head and Neck Neoplasms/complications , Humans , Intestinal Obstruction , Laparotomy , Male , Middle Aged , Neoplasm Staging , Obesity , Prognosis , Retrospective Studies , Young Adult
14.
Acta Anaesthesiol Scand ; 57(10): 1313-20, 2013 Nov.
Article in English | MEDLINE | ID: mdl-23980580

ABSTRACT

BACKGROUND: Two spinal anaesthesia techniques were compared with local infiltration anaesthesia (LIA) to test the hypothesis that the addition of lidocaine to bupivacaine would decrease the spinal block's duration and provide shorter recovery to discharge. METHODS: Ninety-three patients undergoing outpatient herniorrhaphy were randomised into three groups. Spinal anaesthesia: the BL Group (bupivacaine-lidocaine) received 2 ml hyperbaric bupivacaine (10 mg) + 0.6 ml 1% lidocaine (6 mg), the BS Group (bupivacaine-saline) received 2 ml hyperbaric bupivacaine (10 mg) + 0.6 ml saline. LIA: the LIA group received plain bupivacaine + lidocaine. Resolution of the nerve blocks were compared between spinal anaesthesia groups, and post-operative pain scores, analgesic requirements, post-anaesthesia care unit (PACU) time, and discharge time were compared among all groups. RESULTS: Spinal block resolved faster in the BL group vs. the BS group: 194.8 [standard deviation (SD) 29.2] min vs. 236.8 (SD 36.5) min (P = 0.000). PACU and discharge time were shortest in the LIA group [PACU time: 108.7 (SD 27.6) min vs. 113.0 (SD 39.4) min and 151.9 (SD 43.7) min in the BL and BS groups (P = 0.000), and discharge time 108.5 (SD 29.5) min vs. 145.8 (SD 37.3) min and 177.1 (SD 32.0) min in the BL and BS groups, respectively (P = 0.000)]. Pain scores and analgesic consumption were lower, with the time to first analgesic intake being longer in the LIA group. CONCLUSION: Addition of lidocaine to bupivacaine reduced the duration of the spinal block and was associated with shorter recovery times. However, LIA provided the fastest recovery to discharge after outpatient inguinal herniorrhaphy.


Subject(s)
Anesthesia, Local/methods , Anesthesia, Spinal/methods , Anesthetics, Local/pharmacology , Bupivacaine/pharmacology , Lidocaine/pharmacology , Adult , Aged , Humans , Male , Middle Aged , Patient Satisfaction , Time Factors
15.
Acta Chir Belg ; 113(1): 40-2, 2013.
Article in English | MEDLINE | ID: mdl-23550468

ABSTRACT

Chronic pain after inguinal hernia repair with prosthetic meshes is recorded in some patients. Although the exact etiology of the pain is not fully understood, it can be related to the trauma to the regional nerves. It is possible to involve these nerves by injuring, suturing, stapling, tacking or compressing them during the operation. Therefore, a delicate surgical approach to the inguinal floor with correct identification of three nerves is necessary for patient comfort at early and late postoperative period. We herein report a surgical view of an inguinal floor which are very rich of neural structures in a patient undergo an elective inguinal hernia repair. The number of the main nerve bundles was excessive, and they were thicker than generally met. This kind of anatomic variations may create a difficulty for repair with prosthetic material. The identification of the nerve structures was hard at first sight and the correct identification was only made by consulting the surgical picture with a senior anatomist.


Subject(s)
Hernia, Inguinal/surgery , Herniorrhaphy , Inguinal Canal/innervation , Adult , Humans , Male , Prostheses and Implants
16.
Hernia ; 17(2): 167-75, 2013 Apr.
Article in English | MEDLINE | ID: mdl-23142904

ABSTRACT

PURPOSE: Small mesh size has been recognized as one of the factors responsible for recurrence after Lichtenstein hernia repair due to insufficient coverage or mesh shrinkage. The Lichtenstein Hernia Institute recommends a 7 × 15 cm mesh that can be trimmed up to 2 cm from the lateral side. We performed a systematic review to determine surgeons' mesh size preference for the Lichtenstein hernia repair and made a meta-analysis to determine the effect of mesh size, mesh type, and length of follow-up time on recurrence. METHODS: Two medical databases, PubMed and ISI Web of Science, were systematically searched using the key word "Lichtenstein repair." All full text papers were selected. Publications mentioning mesh size were brought for further analysis. A mesh surface area of 90 cm(2) was accepted as the threshold for defining the mesh as small or large. Also, a subgroup analysis for recurrence pooled proportion according to the mesh size, mesh type, and follow-up period was done. RESULTS: In total, 514 papers were obtained. There were no prospective or retrospective clinical studies comparing mesh size and clinical outcome. A total of 141 papers were duplicated in both databases. As a result, 373 papers were obtained. The full text was available in over 95 % of papers. Only 41 (11.2 %) papers discussed mesh size. In 29 studies, a mesh larger than 90 cm(2) was used. The most frequently preferred commercial mesh size was 7.5 × 15 cm. No papers mentioned the size of the mesh after trimming. There was no information about the relationship between mesh size and patient BMI. The pooled proportion in recurrence for small meshes was 0.0019 (95 % confidence interval: 0.007-0.0036), favoring large meshes to decrease the chance of recurrence. Recurrence becomes more marked when follow-up period is longer than 1 year (p < 0.001). Heavy meshes also decreased recurrence (p = 0.015). CONCLUSION: This systematic review demonstrates that the size of the mesh used in Lichtenstein hernia repair is rarely discussed in clinical studies. Papers that discuss mesh size appear to reflect a trend to comply with the latest recommendations to use larger mesh. Standard heavy meshes decrease the recurrence in hernia repair. Even though there is no evidence, it seems that large meshes decrease recurrence rates.


Subject(s)
Hernia, Inguinal/surgery , Herniorrhaphy/instrumentation , Surgical Mesh , Equipment Design , Humans , Recurrence , Treatment Outcome
17.
East Afr Med J ; 90(6): 195-201, 2013 Jun.
Article in English | MEDLINE | ID: mdl-26859026

ABSTRACT

BACKGROUND: Prosthetic mesh repair for abdominal wall hernias is widely used because of its technical simplicity and low hernia recurrence rates. The most commonly used material is pure polypropylene mesh, however newer composite materials are recommended by some centers because of their advantages. However, these meshes are more expensive than pure polypropylene meshes. Resterilisation of a pure polypropylene mesh has been shown to be quite safe, and many centers prefer slicing a large mesh into smaller pieces that suitable for hernia type or defect size. Nevertheless there is no data about the safety after resterilisation of the composite meshes. OBJECTIVE: To search the effects of resterilisation and In vitro degradation in phosphate buffered saline solution on the physical structure and the mechanical properties of partially absorbable lightweigth meshes. DESIGN: Laboratory-based research. SUBJECTS: Two composite meshes were used in the study: One mesh is consisted of monofilament polypropylene and monofilament polyglecaprone--a copolymer of glycolide and epsilon (ε)-caprolactone--(Ultrapro®, 28 g/m2, Ethicon, Hamburg, Germany),andthe otherone consisted of multifilamentpolypropyleneandmultifilament polyglactine (Vypro II®, 30 g/m2,Ethicon, Hamburg, Germany). Two large meshes were cut into rectangular specimens sized 50x20 mm for mechanical testing and 20x20 mm for In vitro degradation experiments. Meshes were divided into control group with no resterilisation and gas resterilisation. Ethylene oxide gas sterilisation was performed at 55°C for 4.5 hours. In vitro degradation in 0.01 M phosphate buffered saline (PBS, pH 7.4) solution at 37 ± 1°C for 8 weeks was applied to one subgroup in each mesh group. Tensiometric measurements and scanning electron microscopyic evaluations were completed for control and resterilisation specimens. RESULTS: Regardless of resterilisation, when meshes were exposed to In vitro degradation, all mechanical parameters decreased significantly. Highest reduction in mechanical properties was observed for Ultrapro due to the degradation of absorbable polyglecaprone and polyglactin parts of these meshes. It was observed that resterilisation by ethylene oxide did not have significant difference on the degradation characteristics and almost similar physical structures were observed for resterilised and non-resterilised meshes. For Vypro II meshes, no significant mechanical difference was observedbetweenresterilised andnon-resterilised meshes after degradationwhile resterilised Ultrapro meshes exhibited stronger characteristics than non-resterilised counterparts, after degradation. CONCLUSION: Resterilisation with ethylene oxide did not affect the mechanical properties of partially absorbable composite meshes. No important surface changeswere observed in scanning electron microscopy after resterilisation.


Subject(s)
Dioxanes , Disinfectants , Ethylene Oxide , Polyesters , Polyglactin 910 , Polypropylenes , Sterilization/methods , Surgical Mesh , Herniorrhaphy/instrumentation , Materials Testing , Tensile Strength , Weight-Bearing
18.
G Chir ; 33(4): 114-8, 2012 Apr.
Article in English | MEDLINE | ID: mdl-22668528

ABSTRACT

BACKGROUND AND AIM: It has been reported that femoral hernias are rather common after a previous repair of inguinal hernia. We herein present a modified patch repair technique for large femoral hernias that develop after a Lichtenstein operation for ipsilateral inguinal hernia. PATIENTS AND METHODS: The modified technique for femoral hernia was applied to three patients who had a Lichtenstein repair for inguinal hernia. All patients were male. Hernia sac is dissected completely and sent back into to the preperitoneal space. Special attention should be given to the prevascular component of the sac. It is dissected as deep as possible into the preperitoneal space over the femoral vein. The defect is quite wide in this particular type of femoral hernia following Lichtenstein repair. A prosthetic patch that matches the defect is prepared. The medial edge of the mesh is configured to correspond to the pubic corner and lacunar ligament. The lateral margin of the patch is cut to create several petals for inverting the mesh above and medial to the femoral vein to prevent prevascular herniation. The mesh is secured to inguinal ligament, ilioinguinal tract, lacunar ligament, and Cooper ligament. Few sutures are put on the pubic corner and lacunar ligament. RESULTS: One patient was discharged after two hours, other two stayed overnight. Readmission because of seroma development was recorded in two cases where standard polypropylene meshes were used. No complication was observed in the other patient who received lightweight meshes. No early recurrences were recorded after 4, 9, and 30 months. CONCLUSION: Femoral recurrence after previous inguinal hernia repair seems to be a specific entity. It has a prevascular component and the hernia defect can be much larger than that of a primary femoral hernia. A patch repair with infra-inguinal approach can be a valuable alternative with low complication rate.


Subject(s)
Hernia, Femoral/surgery , Hernia, Inguinal/surgery , Herniorrhaphy , Postoperative Complications/surgery , Prostheses and Implants , Surgical Mesh , Adult , Aged , Humans , Male , Prosthesis Design
19.
Chirurgia (Bucur) ; 107(1): 47-51, 2012.
Article in English | MEDLINE | ID: mdl-22480115

ABSTRACT

BACKGROUND: To identify variables those predict length of hospital stay separately after groin, primary ventral and incisional hernias. METHODS: A total of 1170 groin, primary ventral, and incisional hernia repairs (n = 959, 132, 79 respectively) and their perioperative variables were analyzed. For each subgroup of hernia type, univariate analysis was performed. Multivariate logistic regression model was used to determine independent variables that predict length of hospital stay in each group of hernia. RESULTS: Out of 1170 repairs; 959 were inguinal, 132 were primary ventral repairs and 79 were incisional hernia repairs. Strangulation (p = 0.021), ASA III-IV class (p < 0.001), longer duration of surgery (p < 0.001), systemic postoperative complications (p < 0.001), and local postoperative complications (p < 0.001) were associated with longer length of hospital stay in inguinal hernia repairs; type of repair procedure (p = 0.028), longer duration of surgery (p < 0.001), and systemic postoperative complications (p = 0.006) were associated with longer length of hospital stay in ventral primary hernias repairs; ASA III-IV class (p = 0.027) and longer duration of surgery (p = 0.003) were associated with longer length of hospital stay in incisional hernia repairs. CONCLUSIONS: Postoperative hospital stay can be predicted before the operation by evaluating certain factors related to the patient or procedure. Longer duration of surgery predict longer hospital stay in all types of ventral hernias where as strangulation, high ASA class, systemic-local postoperative complications, and type of repair procedures may predict longer length of hospital stay in different ventral hernia types.


Subject(s)
Hernia, Inguinal/surgery , Hernia, Ventral/surgery , Herniorrhaphy , Length of Stay , Adolescent , Adult , Aged , Aged, 80 and over , Analysis of Variance , Digestive System Surgical Procedures , Elective Surgical Procedures , Female , Hernia, Ventral/etiology , Humans , Male , Middle Aged , Multivariate Analysis , Retrospective Studies , Risk Factors , Surgical Mesh , Treatment Outcome
20.
Hernia ; 16(2): 145-51, 2012 Apr.
Article in English | MEDLINE | ID: mdl-21928096

ABSTRACT

PURPOSE: In this double-blind prospective randomized trial, our objective was to investigate the effect of antibiotic prophylaxis in patients undergoing elective inguinal hernia surgery with mesh repair in a large-volume tertiary referral trauma center. METHODS: Eligible patients were assigned randomly to either an antibiotic prophylaxis group or a control group. Patients in the prophylaxis group were given 1 g cefazolin by IV bolus injection whereas the placebo control group received an equal volume of sterile saline preoperatively. A Lichtenstein repair was done in all cases. The patients were examined for surgical site infection (SSI) and other postoperative local complications before discharge, and reexamined 3, 5, 7, and 30 days after discharge. RESULTS: Groups were well matched for age, sex, coexisting diseases, ASA scores, type of hernia, type of anesthesia, duration of surgery. Incidence of infection was 7% in the control group (7/100) and 5% in the prophylaxis group (5/100) (P = 0.38). All the infections were superficial and responded well to drainage and proper antibiotic therapy. All other postoperative complications were similar in the two groups. CONCLUSIONS: In our settings antibiotic prophylaxis has no significant effect on the incidence of SSI in elective repair of inguinal hernias with mesh. The most effective way to reduce the incidence of infection in prosthetic repair may be a specific center for treatment of abdominal wall hernias.


Subject(s)
Antibiotic Prophylaxis , Hernia, Inguinal/surgery , Herniorrhaphy , Surgical Wound Infection/prevention & control , Adult , Aged , Aged, 80 and over , Anti-Bacterial Agents/administration & dosage , Cefazolin/administration & dosage , Double-Blind Method , Elective Surgical Procedures , Female , Humans , Incidence , Male , Middle Aged , Prospective Studies , Surgical Wound Infection/epidemiology , Trauma Centers
SELECTION OF CITATIONS
SEARCH DETAIL
...