Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 19 de 19
Filter
1.
Int Orthod ; 22(2): 100869, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38513309

ABSTRACT

OBJECTIVE: To assess the allele rs 1143634 in IL-1ß and rs1800587 in IL-1α in patients for orthodontically induced external apical root resorption (EARR). MATERIAL AND METHODS: Intra-oral periapical radiograph (IOPA) of maxillary incisors of 142 Patients were evaluated for resorption at two time points; before the start of fixed mechanotherapy (T1) and after one year of treatment (T2). The individuals with root resorption<2mm were categorized as a control group (group 1; n=90), and resorption>2mm were categorized as case group (group 2; n=52). Buccal swabs of all patients were taken and DNA could be isolated in 95 out of 142 samples (group 1 {n=58}, group 2 {n=37}), which were then screened for the selected two polymorphic targets to determine the nucleotide status of these targets. Tetra-primer ARMS PCR reactions were carried out using all 4 primers for each polymorphism. RESULTS: rs11800587 was not associated with risk of EARR in any inheritance model. Chi-square test for association of alleles with EARR revealed that rs1143634 was associated with the risk of EARR in an allelic model in such a way that A allele of this SNP increased the risk of EARR 4 folds [OR=4.375; P=0.016]. However, the adjusted level of significance using the Holm-Bonferroni method for rs1143634 was P<0.010 for A and G comparison rendering the results non-significant. CONCLUSION: SNP rs1143634 and SNP rs11800587 were not associated with risk of EARR in any inheritance model.


Subject(s)
Interleukin-1alpha , Interleukin-1beta , Polymorphism, Single Nucleotide , Root Resorption , Adolescent , Child , Female , Humans , Male , Young Adult , Alleles , Case-Control Studies , Incisor , Interleukin-1alpha/genetics , Interleukin-1beta/genetics , Root Resorption/genetics , Root Resorption/etiology
2.
J Orthod Sci ; 12: 29, 2023.
Article in English | MEDLINE | ID: mdl-37351393

ABSTRACT

OBJECTIVES: This study aimed to investigate the correlation of gonial angle and three linear measurements on OPG and lateral cephalograms and their effects on the different facial patterns using the OneCeph android app. METHOD: About 90 pre-treatment digital lateral cephalograms and OPGs of 90 patients were selected and divided into 3 categories, based on their growth patterns. The OPGs and lateral cephalograms were uploaded on the OneCeph android app. After calibrating using One linear measurement i.e. length of extracted premolar for OPG and ruler in radiograph for lateral cephalogram, Gonial angle (Ar- Go-Me), ANS-Me (LAFH), U1-NF, L1-MP were measured. The data were collected, tabulated, and subjected to statistical analysis using the SPSS software (version 20.0). The level of significance was kept at 5%. RESULTS: Values for parameters were highest in the vertical growth pattern followed by average and horizontal in both cephalogram and OPG. Upon comparison of lateral cephalogram and OPG, no significant difference was observed in gonial angle and a significant difference in LAFH and L1-MP in all three growth patterns with OPG scores greater than cephalometric tracing. The interclass coefficient test indicated almost perfect agreement for the gonial angle between the two methods. A substantial agreement was seen for U1-NF on lateral cephalogram and OPG in the vertical group. Also, a fair agreement in the vertical and horizontal group was observed in Lower anterior mandibular height. CONCLUSION: Vertical parameters such as gonial angle and maxillary anterior dental height can be accurately determined on an OPG by the OneCeph application.

3.
J Orthod Sci ; 12: 84, 2023.
Article in English | MEDLINE | ID: mdl-38234637

ABSTRACT

Extractions are commonly used to alleviate moderate to severe crowding, retract protrusive incisors, or correct anteroposterior inconsistencies in the maxillomandibular area. The choice of which teeth to be extracted requires a thorough assessment of the dentition of the patient, taking into account treatment objectives, dental and periodontal properties as well as ease of mechanics with minimum iatrogenic effects. This case report discusses the successful treatment with myofunctional appliance of a growing patient with skeletal Class II malocclusion followed by fixed mechanotherapy involving atypical teeth extraction.

4.
J Orthod Sci ; 11: 51, 2022.
Article in English | MEDLINE | ID: mdl-36411814

ABSTRACT

OBJECTIVE: To evaluate the efficacy of non-aerosol producing restorative self-etching primers (SEPs) as a substitute for conventional orthodontic bonding primers and to analyze the extent of residual composite on the tooth post-debonding. MATERIALS AND METHODS: Eighty-four extracted human premolars were randomly divided into seven groups based on the adhesive and the bonding protocol used. The study comprised Prime and Bond one select (Dentsply), G-Premio Bond (GC), which were each divided into three subgroups based on the method used for moisture control and the control group (Transbond XT conventional total etch). The three methods for moisture control in study groups were: without drying, air-drying with the use of a three-way syringe, and with the use of blotting paper. Shear bond strength (SBS) was tested using a universal testing machine (UTM), and after debonding, the enamel surface of each tooth was examined under 10× magnification to evaluate adhesive remaining index (ARI) scores. RESULTS: Groups 2A (Prime and Bond; without drying) & 1 (Transbond XT) had the lowest and highest SBS values, respectively (P = 0.001). Comparison of ARI between the control group and group 2b (Prime and Bond; air-drying with 3 in 1) showed a significant difference (P = 0.041). Comparison of ARI between control group and group 2c (Prime and Bond; blotting paper) showed a significant difference (P = 0.017). Rest all other comparisons were non-significant. CONCLUSIONS: Transbond XT had SBS values higher than the self-etch groups. Among the self-etch groups, G-Premio Bond had higher SBS values when the traditional methods of air-drying were followed. Use of blotting paper for drying that produced variable SBS values can be an effective alternative method. G-Premio Bond with its adequate bond strength under manufacturer's instruction seems promising in this regard.

5.
J Orthod Sci ; 10: 9, 2021.
Article in English | MEDLINE | ID: mdl-34568205

ABSTRACT

OBJECTIVE: The purpose of this split-mouth single-centered, parallel-group, randomized clinical trial was to evaluate the efficiency of corticotomy-facilitated orthodontics in rapid canine retraction. METHODS: The sample consisted of 10 patients (15-25 years old) requiring extraction of the maxillary first premolars with subsequent canine retraction. The patients' right sides were randomly assigned to either the corticotomy (experimental) or control groups. Corticotomy cuts and perforations were performed and canine retraction was initiated bilaterally with closed-coil nickel-titanium springs that applied 150 g of force. The following variables were examined till the end of canine retraction on both sides: Rate of canine retraction, canine root resorption, and patient perception of the procedure. The rate of canine retraction was assessed every month using study models while root resorption was evaluated using CBCT. Patient`s perception was evaluated using a 100 mm VAS. RESULT: Mean time taken for full completion of canine retraction: 5.7 months (test) and 7.1 months (control). Mean root resorption: 0.53 ± 0.10 (control) and 0.24 mm ± 0.10 (test). Mean VAS scores: 16 ± 3.94 (24 hours) and 2 ± 2.58 (1 week) at control side and 46.50 ± 6.69 (24 hours) and 2 ± 2.58 (1 week) at test. CONCLUSION: There was an overall reduction in the time taken for canine retraction with corticotomy; however, an increase in the rate of canine retraction in the corticotomy-facilitated method was evident only for the first four months, compared to the conventional method. Less root resorption was observed in corticotomy-facilitated method than conventional method. Pain perception was more for corticotomy-facilitated method than conventional method at 24 hours, but similar after one week.

6.
J Orthod Sci ; 10: 12, 2021.
Article in English | MEDLINE | ID: mdl-34568208

ABSTRACT

AIM: To evaluate and compare the efficacy of Ozonated Olive Oil Gel, Chlorhexidine gel, and Amflor (Fluoridated) mouthwash on reducing the count of Streptococcus mutans and Lactobacillus in patients undergoing fixed orthodontic therapy evaluated at different time intervals. METHODS: Sixty patients undergoing orthodontic treatment were randomly divided into three groups (n = 20) based on antimicrobial agents used (Group 1: Ozonated olive oil gel; Group 2: Chlorhexidine gel; Group 3: Fluoridated mouthwash). Elastomeric modules from brackets were collected at T0 (Fresh samples) and T1 (2nd week) and T2 (4th week) for assessment of the microbial growth. These collected modules were cultured and evaluated for the presence of Streptococcus Mutans and Lactobacilli and numbers of colonies were counted at each interval. Data obtained was subjected to statistical analysis using SPSS software (Version 20.0). Level of significance was kept at 5%. Intra-group and inter-group comparison between pretreatment, 2nd week and 4th week was done for each group using Wilcoxon signed rank test and Mann-Whitney U test. RESULTS: There was presence of Streptococcus Mutans and Lactobacilli during orthodontic treatment which progressively increased from To to T1 and then declined from T1 to T2. The colony counts were maximum for Fluoridated mouthwash and least for Chlorhexidine and the results were statistically significant (P < 0.05). CONCLUSION: All three antimicrobial agents used were effective against Streptococcus mutans and Lactobacillus. Chlorhexidine proved to be more efficacious whereas Fluoridated mouthwash proved to be least effective against both Streptococcus mutans and Lactobacillus bacteria.

7.
J Orthod Sci ; 10: 16, 2021.
Article in English | MEDLINE | ID: mdl-34568212

ABSTRACT

OBJECTIVES: The purpose of this study was to evaluate the accuracy and reliability of Mobile Application-Based Software for chair side cephalometric analysis. MATERIALS AND METHOD: Pretreatment lateral cephalograms of 20 patients (10 males and 10 females) were selected randomly and were traced manually and also using Application-based software (One Ceph). 20 angular and three linear parameters were measured both manually and with the software in all the patients. Inter and intra-operator reliability of one ceph was evaluated and the measured parameters were statistically compared with the manual method (Gold Standard). RESULT: The accuracy of angular and linear values was compared for all 23 parameters and our results showed no significant difference in the two methods used for most of the measurements. Three of the measurements [Angle of convexity (N-A; A-Pog); ANB angle; Upper Incisor to NA (Angular)] did show a statistically significant difference though these were clinically irrelevant. CONCLUSION: Application-based cephalometric analysis can be an effective clinical diagnostic tool for chair-side cephalometric evaluation of orthodontic patient.

8.
Int J Clin Pediatr Dent ; 14(1): 149-157, 2021.
Article in English | MEDLINE | ID: mdl-34326602

ABSTRACT

Failure of eruption of maxillary incisors requires careful diagnosis and treatment planning. The cause of impaction may vary from physical obstruction in the path of eruption, tooth material arch length discrepancy to malformation of the tooth. General principles of management of the condition include removal of physical obstruction, creation of space, and surgical exposure with or without traction. The treatment of an unerupted tooth depends upon its age, position, etiology, and amount of space in the dental arch. This case series elaborates on three different cases of incisor impaction with different etiologies and varying ranges of complexity. Three-dimensional radiography was utilized in all cases to accurately visualize the impacted tooth and its relation to adjacent structures. All the cases required different approaches and were completed in varying time durations. Meticulous treatment planning resulted in well-aligned satisfactory functional and esthetic results. How to cite this article: Jain S, Raza M, Sharma P, et al. Unraveling Impacted Maxillary Incisors: The Why, When, and How. Int J Clin Pediatr Dent 2021;14(1):149-157.

9.
J Orthod Sci ; 9: 16, 2020.
Article in English | MEDLINE | ID: mdl-33354542

ABSTRACT

OBJECTIVE: To compare demineralization around orthodontic brackets cured by conventional method and transillumination method. MATERIALS AND METHOD: Sixty freshly extracted human premolar teeth were divided into four groups. Group 1: Brackets bonded with conventional method of bonding by curing labially for 40 sec. Group 2: Brackets bonded with transillumination method of bonding for 50 sec. Group 3: Brackets bonded with conventional method of bonding by curing labially for 20 sec followed by 30 sec of transillumination. Group 4: Brackets bonded with transillumination method of bonding for 30 sec followed by labial curing for 20 sec. Ground sections were prepared of each tooth and microleakage was evaluated using a binocular microscope at 40× magnification (Olympus BX53) and an image was taken using a digital camera (Olympus EPL3) connected to the microscope. The images were analyzed using Magnus Pro Image software. Scores were assigned to different degrees of microleakage at the demineralization zone around enamel-adhesive-bracket complex at the occlusal, middle, and gingival margins using linear measurement tool. Data obtained was subjected to statistical analysis using SPSS software (Version 20.0). Level of significance was kept at 5%. Intragroup comparison was done using Kruskal-Wallis test followed by Mann-Whitney U-tests for pairwise comparison. RESULTS: Group 4 showed least mean demineralization in occlusal, middle, and cervical areas as compared to other groups and the results were statistically significant (P < 0.05). CONCLUSION: Transillumination can be employed as a method synergistically with conventional curing to achieve minimum amount of demineralization during fixed orthodontic treatment.

10.
J Orthod Sci ; 9: 1, 2020.
Article in English | MEDLINE | ID: mdl-32166080

ABSTRACT

OBJECTIVE: To evaluate the antimicrobial property of cetylpyridinium chloride (CPC) when polymerized with cold cure acrylic and to assess the duration of its release from modified acrylic. MATERIALS AND METHODS: CPC was added in different concentrations (0%, 2.5%, 5%, and 10%) to cold cure acrylic resin and 180 acrylic discs were prepared. These were divided into four groups of 45 each depending on the concentration of CPC. The antimicrobial property of the modified acrylic for Streptococcus mutans was tested using disc diffusion assay in agar. The duration of release of CPC from self-cure acrylic was tested with optical density reading of solutions by ultraviolet spectrophotometer. The effect of addition of CPC on diametral tensile strength (DTS) of acrylic was tested using UTM (Instron) and the effect of water aging on modified acrylic was compared with unaged specimens. RESULTS AND CONCLUSION: The normality of the data was checked by Shapiro-Wilktest, and as the data failed to show normal distribution, inferential statistics were performed using nonparametric tests of significance. Antimicrobial activity of modified acrylic increased with increase in CPC concentration. Greatest CPC release was observed on the seventh day with a decrease in release from 7 to 180 days. There was a decrease in the diametral strength of the modified resin and water aging had a significant effect on the DTS of the modified resin.

11.
J Orthod ; 46(1): 27-33, 2019 03.
Article in English | MEDLINE | ID: mdl-31056072

ABSTRACT

OBJECTIVE: To evaluate and compare the leptin levels in gingival crevicular fluid (GCF) and rate of canine retraction using an elastomeric chain and nickel-titanium (NiTi) closed coil spring. DESIGN: In vivo, clinical study. SETTING: Orthodontic department at ITS Centre for Dental Studies and Research, Ghaziabad, India. PARTICIPANTS: Twenty-seven patients reported to the Department of Orthodontics at ITS Centre for Dental Studies and Research. METHODS: Twenty-seven patients were included in the study in which canine retraction was carried out with an elastomeric chain and NiTi closed coil spring on either side of the arch applying 150 g of force on both sides. GCF samples were collected before the commencement of canine retraction, on the first, seventh and 21st day after application of force and were analysed for leptin levels by the ELISA technique. Impressions for the study model were taken at baseline and after 21 days to measure the rate of tooth movement bilaterally with an electronic digital calliper. RESULTS: The results obtained within both groups showed a significant decrease in leptin levels from baseline to 21 days ( P = 0.0001). There was no significant difference in leptin levels between both groups, but leptin levels decreased more in the NiTi closed coil spring group. The rate of tooth movement is not significantly different between both groups, but space closure is faster in the NiTi closed coil spring group. CONCLUSIONS: Leptin levels in GCF showed a significant decrease during canine retraction using an elastomeric chain and NiTi coil spring; there was no significant difference in the rate of tooth movement between both the groups.


Subject(s)
Gingival Crevicular Fluid , Orthodontics , Cuspid , Elasticity , Humans , Leptin , Orthodontic Wires , Titanium , Tooth Movement Techniques
12.
Dental Press J Orthod ; 24(1): 39-43, 2019.
Article in English | MEDLINE | ID: mdl-30916247

ABSTRACT

INTRODUCTION: Proximal stripping of enamel is a routine clinical procedure employed in orthodontics to create space or for balancing tooth size discrepancies. This procedure may result in heat transfer to the pulp, predisposing it to histopathological changes and necrosis of the pulp tissue. OBJECTIVE: To measure the temperature changes in the pulp chamber during different stripping procedures. METHODS: 80 proximal surfaces of 40 extracted human premolar teeth were stripped using four techniques: diamond burs in air-rotor handpiece with air-water spray; diamond burs in micromotor handpiece, with and without a coolant spray; and hand-held diamond strips. A J-type thermocouple connected to a digital thermometer was inserted into the pulp chamber for evaluation of temperature during the stripping procedure. RESULTS: An increase in the pulpal temperature was observed for all stripping method. Diamond burs in micromotor handpiece without coolant resulted in the higher increase in temperature (3.5oC), followed by hand-held diamond strips (2.8oC), diamond burs in air-rotor with air-water spray (1.9oC); and the smallest increase was seen with diamond burs in micromotor handpiece with coolant (1.65oC). None of the techniques resulted in temperature increase above the critical level of 5.5oC. CONCLUSION: Frictional heat produced with different stripping techniques results in increase in the pulpal temperature, therefore, caution is advised during this procedure. A coolant spray can limit the increase in temperature of the pulp.


Subject(s)
Dental Enamel , Dental Pulp Cavity , Dental Pulp , Bicuspid , Dental High-Speed Equipment , Hot Temperature , Humans , Temperature , Tooth Movement Techniques
13.
Dental press j. orthod. (Impr.) ; 24(1): 39-43, Jan.-Feb. 2019. tab, graf
Article in English | LILACS | ID: biblio-989686

ABSTRACT

ABSTRACT Introduction: Proximal stripping of enamel is a routine clinical procedure employed in orthodontics to create space or for balancing tooth size discrepancies. This procedure may result in heat transfer to the pulp, predisposing it to histopathological changes and necrosis of the pulp tissue. Objective: To measure the temperature changes in the pulp chamber during different stripping procedures. Methods: 80 proximal surfaces of 40 extracted human premolar teeth were stripped using four techniques: diamond burs in air-rotor handpiece with air-water spray; diamond burs in micromotor handpiece, with and without a coolant spray; and hand-held diamond strips. A J-type thermocouple connected to a digital thermometer was inserted into the pulp chamber for evaluation of temperature during the stripping procedure. Results: An increase in the pulpal temperature was observed for all stripping method. Diamond burs in micromotor handpiece without coolant resulted in the higher increase in temperature (3.5oC), followed by hand-held diamond strips (2.8oC), diamond burs in air-rotor with air-water spray (1.9oC); and the smallest increase was seen with diamond burs in micromotor handpiece with coolant (1.65oC). None of the techniques resulted in temperature increase above the critical level of 5.5oC. Conclusion: Frictional heat produced with different stripping techniques results in increase in the pulpal temperature, therefore, caution is advised during this procedure. A coolant spray can limit the increase in temperature of the pulp.


RESUMO Introdução: o desgaste proximal do esmalte é um procedimento clínico rotineiro utilizado na Ortodontia para se criar espaços ou equilibrar discrepâncias de tamanho dentário. Esse procedimento pode resultar em transferência de calor para a polpa, predispondo-a a mudanças histopatológicas e necrose do tecido pulpar. Objetivo: medir as mudanças de temperatura na câmara pulpar durante diferentes procedimentos de desgaste interproximal. Métodos: 80 superfícies proximais de 40 pré-molares humanos foram desgastadas utilizando-se quatro técnicas diferentes: brocas diamantadas em motor a ar (alta rotação) com spray de água e ar; brocas diamantadas em micromotor (baixa rotação) com e sem spray de resfriamento; e tiras diamantadas manuais. Um par termoelétrico do tipo J conectado a um termômetro digital foi inserido na câmara pulpar para avaliação da temperatura durante o desgaste proximal. Resultados: foi observado um aumento da temperatura da câmara pulpar em todos os métodos de desgaste proximal. As brocas diamantadas em micromotor sem resfriamento foram responsáveis pelo maior aumento da temperatura (3,5oC), seguidas pelas lixas diamantadas manuais (2,8oC) e brocas diamantadas em motor a ar (alta rotação) com spray de água e ar (1,9oC). O menor aumento foi observado com as brocas diamantadas em micromotor (baixa rotação) com resfriamento (1,65oC). Nenhuma das técnicas elevou a temperatura acima do nível crítico de 5,5oC. Conclusão: o aquecimento friccional produzido pelas diferentes técnicas de desgaste proximal levou ao aumento da temperatura da câmara pulpar; assim, cuidados devem ser tomados durante esse procedimento. O spray de água e ar pode limitar o aumento da temperatura da polpa.


Subject(s)
Humans , Dental Enamel , Dental Pulp , Dental Pulp Cavity , Temperature , Tooth Movement Techniques , Bicuspid , Dental High-Speed Equipment , Hot Temperature
14.
J Orthod Sci ; 6(3): 86-90, 2017.
Article in English | MEDLINE | ID: mdl-28717632

ABSTRACT

OBJECTIVE: To investigate the effect of different intracoronal bleaching methods on the shear bond strength and site of failure of ceramic brackets. MATERIALS AND METHODS: Sixty freshly extracted human maxillary incisors were randomly divided into four groups (n = 15). Endodontic access cavity was prepared and root canals were filled, root fillings were removed 2mm apical to the cementoenamel junction, and a 2-mmthick layer of glass ionomer cement base was applied. Group 1 served as the control. Intracoronal bleaching was performed with 35% carbamide peroxide in group 2, sodium perborate in group 3, and 37.5% hydrogen peroxide in group 4. The teeth were immersed in artificial saliva for 4 weeks before bracket bonding. Ceramic brackets were bonded with composite resin and cured with LED light. After bonding, the shear bond strength of the brackets was tested with a universal testing machine. The site of bond failure was determined by modified ARI (Adhesive Remnant Index). RESULTS: The highest value of shear bond strength was measured in control group (18.67 ± 1.59 MPa), which was statistically significant from groups 2,3, and 4. There was no significant difference between groups 2 and 4. The lowest shear bond strength was measured in group 3. ARI scores were not significant from each other. CONCLUSIONS: Intracoronal bleaching significantly affected the shear bond strength of ceramic brackets even after 4 weeks of bleaching. Bleaching with sodium perborate affects shear bond strength more adversely than does bleaching with other agents like hydrogen peroxide and carbamide peroxide.

15.
Int J Clin Pediatr Dent ; 8(1): 37-41, 2015.
Article in English | MEDLINE | ID: mdl-26124579

ABSTRACT

OBJECTIVE: The aim of the study was to compare and evaluate the in vitro biodegradation of nickel and chromium from space maintainers, made of three different companies, i.e (Dantaurum, Rocky mountain and Dtech) in artificial saliva. MATERIALS AND METHODS: The study comprised of 30 space maintainers out of which 10 were fabricated using Dantaurum, 10 using Rocky mountain and 10 using Dtech band materials. Stainless steel wire (Dantaurum, Rocky mountain and Konark) was used for making loops and Leone solder and flux was used for soldering. Each group was further divided into four subgroups containing 1, 2, 3 and 4 space maintainers respectively. The space maintainers in each subgroup were placed in separate glass beakers containing 100 ml of artificial saliva at 37°C for 4 weeks. Salivary samples from each beaker was analyzed for nickel and chromium ions separately on days 1, 7, 14, 21 and 28 days using inductively coupled plasma-optical emission spectrophotometer. RESULTS: Total release of nickel and chromium from all band and loop space maintainers ranged from 0.020 to 1.524 ppm and 0.002 to 0.289 ppm respectively. The release of nickel and chromium between the groups and within the groups was not significant (p < 0.5). CONCLUSION: There was no substantial release of nickel and chromium from space maintainers made of Dantaurum, Rocky mountain and Dtech which could cause any toxicity. How to cite this article: Anand A, Sharma A, Kumar P, Sandhu M, Sachdeva S, Sachdev V. A Comparative Study of Biodegradation of Nickel and Chromium from Space Maintainers: An in vitro Study. Int J Clin Pediatr Dent 2015; 8(1):37-41.

16.
J Orthod Sci ; 3(1): 12-6, 2014 Jan.
Article in English | MEDLINE | ID: mdl-24987658

ABSTRACT

BACKGROUND: An important stage at the very beginning of orthodontic therapy is the separation of teeth where space is created for banding of the molars. A dislodged separator may create problems if ingested or it may get wedged between the adjacent teeth causing acute localized periodontitis. In order to overcome these shortcomings of conventional separators, the Kansal Separator was conceptualized. This separator has been designed as a single device that acts simultaneously on both mesial and distal aspects of tooth, causing adequate separation. In addition to separator's independent 2 in 1 action, the self-locking connecting bar prevents the premature dislodgement of the separator. AIM: To determine the force vectors produced by Kansal separator. MATERIALS AND METHODS: A prototype model was created to study the forces produced. RESULTS: The separator's unique design is based on sound biomechanical principles that explicate the proof of concept and allows the separator to be distinctly effective and efficient in variable clinical situations, thus amplifying its uniqueness. DISCUSSION: The Kansal Separator, a 2 in 1 orthodontic tooth separator, has a unique design enabling the device to simultaneously separate the teeth on the mesial and distal aspect of the tooth to be banded. CONCLUSION: Kansal Separator's unique design is based on sound biomechanical principles that explicate the proof of concept and allows the separator to be distinctly effective and efficient in variable clinical situations, thus amplifying its uniqueness.

17.
J Orthod Sci ; 2(1): 23-7, 2013 Jan.
Article in English | MEDLINE | ID: mdl-24987639

ABSTRACT

AIM: The purpose of this study was to evaluate the Bolton overall ratio in a north Indian population reporting for orthodontic treatment and to determine the effect of extractions on the Bolton ratios. Another aim of the study was to check the effects of different extraction patterns on the final Bolton ratio. MATERIALS AND METHODS: One hundred and twenty pre-treatment dental casts (60 males and 60 females) of orthodontic patients were selected randomly. Mesio-distal dimensions of the mandibular and maxillary teeth were measured before treatment, and subjected to Bolton analysis. Hypothetical tooth extraction by the following combinations: All the first premolars, all the second premolars, upper first and lower second premolars and upper second and lower first premolars were performed for each patient. The measurement results were again subjected to Bolton analysis to see whether any tooth-size discrepancy had been created. RESULTS AND CONCLUSION: The tooth material ratio of the studied north Indian population shows a mild maxillary tooth material excess. Extraction of premolars in any combination causes the maxillary tooth material to further increase. There is no significant sex difference in the tooth material ratios with or without extractions. In patients requiring extraction; all first premolar extraction or maxillary first and mandibular second premolar extraction should be preferred. For deciding a treatment plan involving extraction of teeth, we need to consider that the maxillary tooth mass may increase after extraction. Furthermore, the normal or the clinically significant tooth size discrepancies may change following extraction of teeth.

18.
J Orthod Sci ; 2(2): 55-60, 2013 Apr.
Article in English | MEDLINE | ID: mdl-24987643

ABSTRACT

AIMS: To assess the sex discrimination potential of permanent maxillary molar crown widths and cusp diameters. MATERIALS AND METHODS: Measurements were made on plaster casts of 200 individuals of known sex (100 males, 100 females, aged 12-21 years). Eight parameters were measured on the first and second maxillary molars with a digital caliper [buccolingual, mesiodistal, mesiobuccal-distolingual and distobuccal-mesiolingual crown widths and cusp diameters (hypocone, protocone, paracone, and metacone)]. The percentage of sexual dimorphism for each parameter was calculated. Discriminant function analysis was used to determine the accuracy of sex determination for each molar separately and both the molars taken together. RESULTS: The highest sexual dimorphism was shown by protocone in the first molar and hypocone in the second molar. Furthermore, the sex determination accuracy was highest when the first molar was taken alone than when the second molar or the first and second molars were taken together. CONCLUSION: Based on this study, odontometric measurements of maxillary molars provide low to moderate sex determination accuracy.

SELECTION OF CITATIONS
SEARCH DETAIL
...