Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Type of study
Language
Publication year range
1.
Appl Opt ; 61(2): 532-539, 2022 Jan 10.
Article in English | MEDLINE | ID: mdl-35200894

ABSTRACT

Simultaneous high-speed stereo-particle image velocimetry, OH planar-laser-induced fluorescence (PLIF), and CH2O PLIF measurements in a vitiated bluff body combustor are considered. An ex situ, simultaneous, time-resolved laser sheet intensity profile correction procedure is introduced. This procedure is easily implemented experimentally and is capable of correcting multiple sheets at the same time. As a proof of concept, the procedure is applied to perform correction of the CH2O PLIF images in vitiated and unvitiated conditions. The challenges associated with CH2O PLIF under these combustor operating conditions are also discussed.

2.
Int J Low Extrem Wounds ; : 15347346211047098, 2021 Oct 07.
Article in English | MEDLINE | ID: mdl-34617810

ABSTRACT

Diabetic foot ulcers, with worldwide prevalence ranging from 12%-25%, are an important cause of nontraumatic lower limb amputation. Evidence-based assessment of early infection can help the clinician provide the right first line treatment thus helping improve the wound closure rate. Illuminate®, a novel point of care device working on multispectral autofluorescence imaging, helps in the rapid identification and classification of bacteria. This study was aimed to evaluate the diagnostic accuracy of the device in detecting bacterial gram type against standard culture methods. A total of 178 patients from a tertiary care center for diabetes was recruited and 203 tissue samples were obtained from the wound base by the plastic surgeon. The device was handled by the trained investigator to take wound images. The tissue samples were taken from the color-coded infected region as indicated by the device's Artificial Intelligence algorithm and sent for microbial assessment. The results were compared against the Gram type inferred by the device and the device was found to have an accuracy of 89.54%, a positive predictive value of 86.27% for detecting Gram-positive bacteria, 80.77% for Gram-negative bacteria, and 91.67% for no infection. The negative predictive value corresponded to 87.25% for Gram-positive, 92% for Gram-negative, and 96.12% for no infection. The Results exhibited the accuracy of this novel autofluorescence device in identifying and classifying the gram type of bacteria and its potential in significantly aiding clinicians towards early infection assessment and treatment.

SELECTION OF CITATIONS
SEARCH DETAIL
...