ABSTRACT

Multiplex detection is a smart and an emerging approach in point-of-care testing as it reduces analysis time and testing cost by detecting multiple analytes or biomarkers simultaneously which are crucial for disease detection at an early stage. Application of inexpensive substrate such as paper has immense potential and matter of research interest in the area of point of care testing for multiplexed analysis as it possesses several unique advantages. This study presents the use of paper, strategies adopted to refine the design created on paper and lateral flow strips to enhance the signal, increase the sensitivity and specificity of multiplexed biosensors. An overview of different multiplexed detection studies performed using biological samples has also been reviewed along with the challenges and advantages offered by multiplexed analysis.


Subject(s)
Biosensing Techniques , Point-of-Care Systems , Biomarkers , Point-of-Care Testing
2.
Biosensors (Basel) ; 12(11)2022 Nov 11.
Article in English | MEDLINE | ID: mdl-36421125

ABSTRACT

This article reports a simple and inexpensive leak-proof paper pad with an initial selection of a paper substrate on the grounds of surface morphology and fluid absorption time. Herein, a drying method is used for glucose detection on a paper pad through colorimetric analysis, and the spot detection of glucose is analyzed by optimizing the HRP concentration and volume to obtain accurate results. The rapid colorimetric method for the detection of glucose on the paper pad was developed with a limit of detection (LOD) of 2.92 mmol L-1. Furthermore, the effects of the detection conditions were investigated and discussed comprehensively with the help of chemometric methods. Paper pads were developed for glucose detection with a range of 0.5-20 mM (apropos to the normal glucose level in the human body) and 0.1-0.5 M (to test the excessive intake of glucose). The developed concept has huge potential in the healthcare sector, and its extension could be envisioned to develop the reported paper pad as a point-of-care testing device for the initial screening of a variety of diseases.


Subject(s)
Biosensing Techniques , Colorimetry , Humans , Colorimetry/methods , Paper , Chemometrics , Biosensing Techniques/methods , Glucose/analysis
SELECTION OF CITATIONS
SEARCH DETAIL
...