Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Med Ultrasound ; 30(1): 11-19, 2022.
Article in English | MEDLINE | ID: mdl-35465598

ABSTRACT

Background: The commercially available training phantoms being expensive, homemade models are popular surrogates for training. We intended to study how comparable our indigenously developed ultrasound phantom (IDUP) was with the commercially available model for ultrasound-guided vascular access (USGVA) training. We also assessed the change in confidence among trainees using a 21-h standardized program. Methods: A prospective randomized double-blinded, parallel design study, with sequential allocation, was done after a standardized point of care ultrasound training course. Over three consecutive courses, 48 trainees volunteered to take part in the study. The models (IDUP and commercial phantom) were allocated as model A and model B. In each course, participants were also allotted sequentially to either perform in-plane or out of plane approach first, at the testing stations. Wilcoxon signed-rank test was used to compare pretest with posttest scores. Results: There was a statistically significant difference between IDUP and commercial phantom with respect to the resemblance to human tissue on tactile feedback and ease to perform the procedure. However, both models did not show a statistically significant difference in terms of ease of use, visual resemblance to human tissue, needle visualization, and artifacts on ultrasonography display. A significant change in the confidence levels of participants was seen postcourse. Conclusion: IDUP was a comparable alternative to the commercial model for USGVA training in a resource-limited setting. A 21-h standardized training program improved the trainee's confidence in performing and teaching USGVA.

2.
Turk J Emerg Med ; 20(4): 193-195, 2020.
Article in English | MEDLINE | ID: mdl-33089028

ABSTRACT

Succinylcholine is a short-acting depolarizing neuromuscular blocking agent. We describe a case where the above drug was employed for self-harm by a health-care worker. The patient, a 28-year-old female, was brought to the emergency department (ED) in impending respiratory arrest and altered mental status. On arrival, she had hypoxia, bradycardia, and hypotension. Although the cause for rapid deterioration in this patient was unknown, the ED physician still went ahead by resuscitating the patient's airway, breathing, and circulation. During the course of resuscitation, information was received that an empty ampoule of succinylcholine was recovered from her bathroom. Further clinical examination and laboratory investigations led the treating physicians to suspect deliberate intravenous injection of succinylcholine. She was mechanically ventilated and monitored in the critical care unit. Targeted temperature management was initiated in the ED and was continued for 24 h. The patient was discharged from the hospital without any neurological deficits after 4 days. Patients with acute poisoning are one of the major encounters in ED, and this case highlights the possibility of anesthetic drug misuse in any health-care workers coming to the ED with sudden cardiac arrest, altered sensorium, or abnormal vitals. This is the first report describing the survival of a patient following intentional succinylcholine injection for self-harm.

3.
J Med Ultrasound ; 27(4): 187-191, 2019.
Article in English | MEDLINE | ID: mdl-31867192

ABSTRACT

BACKGROUND AND OBJECTIVES: Central venous catheter placement is a frequently performed procedure in emergency medicine as well as critical care unit. We aimed to compare real-time ultrasonography (USG)-guided and the traditional anatomical landmark (AL) technique for the insertion of internal jugular vein (IJV) catheters in an emergency department (ED) setting. MATERIALS AND METHODS: Patients requiring IJV catheterization were prospectively recruited over a period of 1 year at a single center. Cannulation was done either by the AL or USG technique, according to ED physician's discretion. A preset pro forma was completed for each central line placed. Variables were compared using the independent t-test, Fisher's exact test, and the nonparametric Mann-Whitney U-test. RESULTS AND DISCUSSION: Seventy patients were enrolled, of which 35 patients underwent IJV cannulation by USG-guided technique (USG group) and 35 patients by the AL technique (AL group). There were a 100% success rate (35/35) for cannulation in the USG group and a 91.4% success rate (32/35) in the AL group. The catheter was placed on the first attempt in 17 (48.6%) patients in the AL group and 32 (91.4%) patients in the USG group. In th AL group, there were three failed cannulation attempts in comparison to the USG group. The mean start to flash time for the AL technique was 16.59 s (±10.67) and 4.86 s (±2.18) in the USG group. The mean cannulation time was 305.88 s (±66.84) in the AL group and 293.03 s (±71.15) in the USG group. A total of seven acute complications were noted, of which 2 (5.7%) in the USG group and 5 (14.3%) in the AL group. CONCLUSION: The real-time USG guided technique significantly reduces the number of attempts to cannulate, has a higher first-pass success rate, a quicker flash time, and fewer complications when compared to the AL technique. In EDs equipped with USG, insertion of IJV catheters under real-time USG guidance should become the standard of care.

SELECTION OF CITATIONS
SEARCH DETAIL
...