Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Chromatogr A ; 1186(1-2): 222-7, 2008 Apr 04.
Article in English | MEDLINE | ID: mdl-17988672

ABSTRACT

A recently developed hyphenated system for "organic" size-exclusion chromatography-pyrolysis-gas chromatography-mass spectrometry (SEC-Py-GC-MS) is adapted to allow the use of aqueous LC eluents as applied in the characterization of water-soluble polymers. The system uses syringe-based transfer of multiple LC-fractions to the GC instrument with solvent elimination and subsequent pyrolysis in a programmed temperature vaporization injector. The problems of the large-volume injections of aqueous, salt containing eluents into the Py-GC-MS are solved by using a 'sintered-bed liner' for elimination of the water at a high temperature, a volatile salt and the installation of a back-flush option. After optimization, the system was applied for the determination of the combined molecular weight-chemical composition of a polyethylene glycol-polypropylene glycol block copolymer. This analysis was done with the system in the aqueous SEC-Py-GC-MS mode. Also demonstrated is the automated at-line characterization of a random polystyrene-polymethylmethacrylate copolymer, now with the system in the gradient reversed-phase LC-Py-GC-MS mode. The methods proposed in the present work are very useful for the detailed characterization of water-soluble copolymers.


Subject(s)
Gas Chromatography-Mass Spectrometry/methods , Polymers/chemistry , Temperature , Water/chemistry , Chromatography, Gel , Chromatography, Liquid , Polyethylene Glycols/analysis , Polyethylene Glycols/chemistry , Polymethyl Methacrylate/analysis , Polymethyl Methacrylate/chemistry , Solubility
2.
J Chromatogr A ; 1143(1-2): 182-9, 2007 Mar 02.
Article in English | MEDLINE | ID: mdl-17208247

ABSTRACT

On-line coupled size exclusion chromatography-pyrolysis gas chromatography mass spectrometry (SEC-Py-GC-MS) is studied as a novel tool for the characterization of complex polymer samples. An automated system for on-line SEC-Py-GC-MS allowing transfer of multiple fractions was developed based on stop-flow operation of the SEC dimension, syringe-based transfer of the SEC fraction to the GC instrument and solvent elimination with subsequent pyrolysis in a programmed temperature vaporization (PTV) injector. After optimization the system was applied to the characterization of a complex terpolymer composed of very similar monomers. The use of the system for combined pyrolysis and additive analyses in polycarbonate was also demonstrated. Results obtained with the new method indicate the interesting potentials of the method for detailed characterization of polymeric materials.


Subject(s)
Chromatography, Gel/methods , Gas Chromatography-Mass Spectrometry/methods , Polymers/chemistry
3.
J Chromatogr A ; 1023(2): 165-74, 2004 Jan 16.
Article in English | MEDLINE | ID: mdl-14753682

ABSTRACT

Nowadays, large-volume injection is widely used for the GC determination of trace analytes, specifically to improve detectability. The most popular injectors for large-volume injections are the programmable temperature vaporisation (PTV) injector and the cold on-column (COC) injector, where each device has its own advantages and limitations. The novel AT-column concentrating technique combines features of two other injection techniques, loop-type large-volume and vapour overflow. AT-column injection is based on solvent evaporation in an empty liner with solvent vapour discharge via the split line. Little or no optimisation is required. The only relevant parameter is the injection temperature which can easily be calculated using the equation of Antoine. As an application, AT-column injection is combined with GC-MS for the trace-level determination of labile analytes and with GC-flame ionisation detection for the analysis of high molecular weight polymer additives. In summary, AT-column is an injection technique that combines the inertness of the COC, and the flexibility and robustness of the PTV large-volume technique.


Subject(s)
Chromatography, Gas/instrumentation , Temperature
SELECTION OF CITATIONS
SEARCH DETAIL
...