Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Heliyon ; 8(12): e12076, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36561677

ABSTRACT

Infants have a low capacity to thermally adapt to their environment and so sufficient consideration must be given to their thermal environment. In investigating an infant's thermal environment, the purpose of this study is to clarify the heat transfer coefficient in natural convection for the posture of an infant in a stroller. The heat transfer coefficients were measured by means of using a thermal manikin. The experimental thermal environment conditions were set for eight cases, at: 16 °C, 18 °C, 20 °C, 22 °C, 24 °C, 26 °C, 28 °C, and 30 °C, and the air and wall surface temperatures were equalized, creating a homogeneous thermal environment. The air velocity (less than 0.2 m/s) and relative humidity (50%RH) were the same for each case. The surface temperature of each part of the thermal manikin was controlled to 34 °C. The difference between the mean surface temperature and air temperature (ΔT [K]) is the driving force for the heat transfer coefficient in natural convection for the posture of an infant in a stroller (hc [W/(m2·K)]). We propose the use of the empirical formula hc = 2.16 ΔT 0 .23. The formula of the convective heat transfer coefficient in natural convection of this study can be applied to infants up to about 3 years old.

2.
J Therm Biol ; 71: 10-16, 2018 Jan.
Article in English | MEDLINE | ID: mdl-29301678

ABSTRACT

The wet bulb globe temperature (WBGT) is an effective measure for risk screening to prevent heat dISOrders. However, a heat risk evaluation by WBGT requires adjustments depending on the clothing. In this study, we proposed a new effective WBGT (WBGTeff*) for general vapor permeable clothing ensembles and vapor impermeable protective clothing that is applicable to occupants engaged in moderate intensity work with a metabolic heat production value of around 174W/m2. WBGTeff* enables the conversion of heat stress into the scale experienced by the occupant dressed in the basic clothing ensemble (work clothes) based on the heat balances for a human body. We confirmed that WBGTeff* was effective for expressing the critical thermal environments for the prescriptive zones for occupants wearing vapor impermeable protective clothing. Based on WBGTeff*, we succeeded in clarifying how the weights for natural wet bulb, globe, and air temperatures and the intercept changed depending on clothing properties and the surrounding environmental factors when heat stress is expressed by the weighted sum of natural wet bulb, globe, and air temperatures and the intercept. The weight of environmental temperatures (globe and air temperatures) for WBGTeff* for vapor impermeable protective clothing increased compared with that for general vapor permeable clothing, whereas that of the natural wet bulb temperature decreased. For WBGTeff* in outdoor conditions with a solar load, the weighting ratio of globe temperature increased and that of air temperature decreased with air velocity. Approximation equations of WBGTeff* were proposed for both general vapor permeable clothing ensembles and for vapor impermeable protective clothing.


Subject(s)
Hot Temperature , Models, Theoretical , Protective Clothing/standards , Steam , Thermometry/standards , Heat-Shock Response , Humans , Humidity , Sunlight , Thermometry/methods , Wind
3.
J Therm Biol ; 71: 1-9, 2018 Jan.
Article in English | MEDLINE | ID: mdl-29301677

ABSTRACT

The purpose of this study is to expand the empirically derived wet bulb globe temperature (WBGT) index to a rational thermal index based on the heat balance for a human body. We derive the heat balance model in the same form as the WBGT for a human engaged in moderate intensity work with a metabolic heat production of 174W/m2 while wearing typical vapor-permeable clothing under shady and sunny conditions. Two important relationships are revealed based on this derivation: (1) the natural wet bulb and black globe temperature coefficients in the WBGT coincide with the heat balance equation for a human body with a fixed skin wettedness of approximately 0.45 at a fixed skin temperature; and (2) the WBGT can be interpreted as the environmental potential to increase skin temperature rather than the heat storage rate of a human body. We propose an adjustment factor calculation method that supports the application of WBGT for humans dressed in various clothing types and working under various air velocity conditions. Concurrently, we note difficulties in adjusting the WBGT by using a single factor for humans wearing vapor-impermeable protective clothing. The WBGT for shady conditions does not need adjustment depending on the positive radiant field (i.e., when a radiant heat source exists), whereas that for the sunny condition requires adjustments because it underestimates heat stress, which may result in insufficient human protection measures.


Subject(s)
Heat-Shock Response , Hot Temperature/adverse effects , Models, Theoretical , Skin Temperature , Thermometry/methods , Heat Stroke/etiology , Heat Stroke/prevention & control , Humans , Humidity/adverse effects , Sunlight/adverse effects , Thermometry/standards
4.
Int J Biometeorol ; 58(5): 963-74, 2014 Jul.
Article in English | MEDLINE | ID: mdl-23729172

ABSTRACT

The influence of short wave solar radiation appears to be strong outdoors in summer, and the influence of airflow appears to be strong outdoors in winter. The purpose of this paper was to clarify the influence of the outdoor environment on young Japanese females. This research shows the relationship between the physiological and psychological responses of humans and the enhanced conduction-corrected modified effective temperature (ETFe). Subjective experiments were conducted in an outdoor environment. Subjects were exposed to the thermal environment in a standing posture. Air temperature, humidity, air velocity, short wave solar radiation, long wave radiation, ground surface temperature, sky factor, and the green solid angle were measured. The temperatures of skin exposed to the atmosphere and in contact with the ground were measured. Thermal sensation and thermal comfort were measured by means of rating the whole-body thermal sensation (cold-hot) and the whole body thermal comfort (comfortable-uncomfortable) on a linear scale. Linear rating scales are given for the hot (100) and cold (0), and comfortable (100) and uncomfortable (0) directions only. Arbitrary values of 0 and 100 were assigned to each endpoint, the reported values read in, and the entire length converted into a numerical value with an arbitrary scale of 100 to give a linear rating scale. The ETFe considered to report a neither hot nor cold, thermally neutral sensation of 50 was 35.9 °C, with 32.3 °C and 42.9 °C, respectively, corresponding to the low and high temperature ends of the ETFe considered to report a neither comfortable nor uncomfortable comfort value of 50. The mean skin temperature considered to report a neither hot nor cold, thermally neutral sensation of 50 was 33.3 °C, with 31.0 °C and 34.3 °C, respectively, corresponding to the low and high temperature ends of the mean skin temperature considered to report a neither comfortable nor uncomfortable comfort value of 50. The acceptability raised the mean skin temperature even for thermal environment conditions in which ETFe was high.


Subject(s)
Environment , Thermosensing , Weather , Adult , Asian People/psychology , Female , Humans , Skin Temperature , Young Adult
5.
J Environ Public Health ; 2013: 418742, 2013.
Article in English | MEDLINE | ID: mdl-23861691

ABSTRACT

In order to manage the outdoor thermal environment with regard to human health and the environmental impact of waste heat, quantitative evaluations are indispensable. It is necessary to use a thermal environment evaluation index. The purpose of this paper is to clarify the relationship between the psychological thermal responses of the human body and winter outdoor thermal environment variables. Subjective experiments were conducted in the winter outdoor environment. Environmental factors and human psychological responses were measured. The relationship between the psychological thermal responses of the human body and the outdoor thermal environment index ETFe (enhanced conduction-corrected modified effective temperature) in winter was shown. The variables which influence the thermal sensation vote of the human body are air temperature, long-wave thermal radiation and short-wave solar radiation. The variables that influence the thermal comfort vote of the human body are air temperature, humidity, short-wave solar radiation, long-wave thermal radiation, and heat conduction. Short-wave solar radiation, and heat conduction are among the winter outdoor thermal environment variables that affect psychological responses to heat. The use of thermal environment evaluation indices that comprise short-wave solar radiation and heat conduction in winter outdoor spaces is a valid approach.


Subject(s)
Body Temperature Regulation , Environment , Thermosensing , Female , Humans , Japan , Models, Theoretical , Seasons , Temperature , Weather , Young Adult
6.
Eur J Appl Physiol ; 93(3): 273-85, 2004 Dec.
Article in English | MEDLINE | ID: mdl-15338219

ABSTRACT

In order to clarify the heat transfer area involved in convective heat exchange for the human body, the total body surface area of six healthy subjects was measured, and the non-convective heat transfer area and floor and chair contact areas for the following nine common body positions were measured: standing, sitting on a chair, sitting in the seiza position, sitting cross-legged, sitting sideways, sitting with both knees erect, sitting with a leg out, and the lateral and supine positions. The main non-convective heat transfer areas were: the armpits (contact between the upper arm and trunk regions), contact between the two legs, contacts between the fingers and toes, and contact between the hands and the body surface. Also, when sitting on the floor with some degree of leg contact (sitting in the seiza position, cross-legged, or sideways), there was a large non-convective heat transfer area on the thighs and legs. Even when standing or sitting in a chair, about 6-8% of the body surface did not transfer heat by convection. The results showed that the effective thermal convective area factor for the naked whole body in the standing position was 0.942. While sitting in a chair this factor was 0.860, while sitting in a chair but excluding the chair contact area it was 0.918, when sitting in the seiza position 0.818, when sitting cross-legged 0.843, in the sideways sitting position 0.855, when sitting with both knees erect 0.887, in the leg-out sitting position 0.906, while in the lateral position it was 0.877 and the supine position 0.844. For all body positions, the effective thermal convective area factor was greater than the effective thermal radiation area factor, but smaller than the total body surface area.


Subject(s)
Body Surface Area , Convection , Hot Temperature , Adult , Female , Humans , Male , Posture
SELECTION OF CITATIONS
SEARCH DETAIL
...