Results 1 - 9 de 9
Filter
1.
J Cardiovasc Electrophysiol ; 35(4): 802-810, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38409896

ABSTRACT

INTRODUCTION: The Mt. FUJI multicenter trial demonstrated that a delivery catheter system had a higher rate of successful right ventricular (RV) lead deployment on the RV septum (RVS) than a conventional stylet system. In this subanalysis of the Mt. FUJI trial, we assessed the differences in electrocardiogram (ECG) parameters during RV pacing between a delivery catheter system and a stylet system and their associations with the lead tip positions. METHODS: Among 70 patients enrolled in the Mt FUJI trial, ECG parameters, RV lead tip positions, and lead depth inside the septum assessed by computed tomography were compared between the catheter group (n = 36) and stylet group (n = 34). RESULTS: The paced QRS duration (QRS-d), corrected paced QT (QTc), and JT interval (JTc) were significantly shorter in the catheter group than in the stylet group (QRS-d: 130 ± 19 vs. 142 ± 15 ms, p = .004; QTc: 476 ± 25 vs. 514 ± 20 ms, p < .001; JTc: 347 ± 24 vs. 372 ± 17 ms, p < .001). This superiority of the catheter group was maintained in a subgroup analysis of patients with an RV lead tip position at the septum. The lead depth inside the septum was greater in the catheter group than in the stylet group, and there was a significant negative correlation between the paced QRS-d and the lead depth. CONCLUSION: Using a delivery catheter system carries more physiological depolarization and repolarization during RVS pacing and deeper screw penetration in the septum in comparison to conventional stylet system. The lead depth could have a more impact on the ECG parameters rather than the type of pacing lead.


Subject(s)
Cardiac Pacing, Artificial , Ventricular Septum , Humans , Cardiac Pacing, Artificial/adverse effects , Cardiac Pacing, Artificial/methods , Catheters , Electrocardiography/methods , Heart Ventricles/diagnostic imaging , Heart Ventricles/surgery , Ventricular Septum/diagnostic imaging
2.
Europace ; 25(4): 1451-1457, 2023 04 15.
Article in English | MEDLINE | ID: mdl-36794652

ABSTRACT

AIMS: Although the delivery catheter system for pacemaker-lead implantation is a new alternative to the stylet system, no randomized controlled trial has addressed the difference in right ventricular (RV) lead placement accuracy to the septum between the stylet and the delivery catheter systems. This multicentre prospective randomized controlled trial aimed to prove the efficacy of the delivery catheter system for accurate delivery of RV lead to the septum. METHODS AND RESULTS: In this trial, 70 patients (mean age 78 ± 11 years; 30 men) with pacemaker indications of atrioventricular block were randomized to the delivery catheter or the stylet groups. Right ventricular lead tip positions were assessed using cardiac computed tomography within 4 weeks of pacemaker implantation. Lead tip positions were classified into RV septum, anterior/posterior edge of the RV septal wall, and RV free wall. The primary endpoint was the success rate of RV lead tip placement to the RV septum. RESULTS: Right ventricular leads were implanted as per allocation in all patients. The delivery catheter group had higher success rate of RV lead deployment to the septum (78 vs. 50%; P = 0.024) and narrower paced QRS width (130 ± 19 vs. 142 ± 15 ms P = 0.004) than those in the stylet group. However, there was no significant difference in procedure time [91 (IQR 68-119) vs. 85 (59-118) min; P = 0.488] or the incidence of RV lead dislodgment (0 vs. 3%; P = 0.486). CONCLUSION: The delivery catheter system can achieve a higher success rate of RV lead placement to the RV septum and narrower paced QRS width than the stylet system. TRIAL REGISTRATION NUMBER: jRCTs042200014 (https://jrct.niph.go.jp/en-latest-detail/jRCTs042200014).


Subject(s)
Cardiac Pacing, Artificial , Ventricular Septum , Male , Humans , Aged , Aged, 80 and over , Prospective Studies , Cardiac Pacing, Artificial/methods , Heart Ventricles/diagnostic imaging , Ventricular Septum/diagnostic imaging , Catheters , Electrocardiography/methods
4.
BMJ Open ; 11(5): e046782, 2021 05 26.
Article in English | MEDLINE | ID: mdl-34039576

ABSTRACT

INTRODUCTION: Pacing-induced cardiomyopathy occasionally occurs in patients undergoing pacemaker implantation. Although compared with right ventricular (RV) apical pacing, RV septal pacing can attenuate left ventricular dyssynchrony; the success rate of lead placement on the RV septum using the stylet system is low. Additionally, no randomised controlled trial has addressed the issue regarding the accuracy of RV lead placement on the RV septum using the stylet and delivery catheter systems. This study hypothesises that a newly available delivery catheter system can improve the accuracy of RV lead placement on the RV septum. METHODS AND ANALYSIS: In a multicentre, prospective, randomised, single-blind, controlled trial, 70 patients with pacemaker indication owing to atrioventricular block will be randomised to either the delivery catheter or stylet group before the pacemaker implantation procedure. The position of the RV lead tip will be assessed using ECG-gated cardiac CT in all patients within 4 weeks after pacemaker implantation. Lead tip positions are classified into three groups: (1) RV septum, (2) anterior/posterior edge of the RV septal wall and (3) RV free wall. The primary endpoint will be the success rate of RV lead tip placement on the RV septum, which will be evaluated using cardiac CT. ETHICS AND DISSEMINATION: This study will be conducted according to the stipulations of the Helsinki Declaration and the institutional review board of Hamamatsu University School of Medicine. The results of the study will be disseminated at several research conferences and will be published in peer-reviewed journals. TRIAL REGISTRATION NUMBER: jRCTs042200014; Pre-results.


Subject(s)
Ventricular Septum , Catheters , Heart Ventricles/diagnostic imaging , Humans , Multicenter Studies as Topic , Prospective Studies , Randomized Controlled Trials as Topic , Single-Blind Method , Tomography, X-Ray Computed , Ventricular Septum/diagnostic imaging
5.
Intern Med ; 59(1): 83-87, 2020 Jan 01.
Article in English | MEDLINE | ID: mdl-31484910

ABSTRACT

Mutations in the cardiac sodium channel SCN5A can cause phenotypic overlap syndrome of long QT syndrome and Brugada syndrome. However, Brugada-type ST elevations in patients with overlap syndrome are often concealed, which creates a diagnostic challenge. A 38-year-old man was admitted due to ventricular fibrillation (VF). The 12-lead electrocardiogram showed a prolonged QT interval and saddleback-type ST elevation. Pilsicainide administration induced coved-type ST elevation and VF triggered by a single premature ventricular contraction. A genetic analysis showed an SCN5A c.5350G>A p.E1784K mutation. The present case suggests the importance of a drug administration test being performed in the clinical management of overlap syndrome.


Subject(s)
Anti-Arrhythmia Agents , Brugada Syndrome/diagnosis , Lidocaine/analogs & derivatives , Long QT Syndrome/diagnosis , Ventricular Fibrillation/physiopathology , Adult , Brugada Syndrome/complications , Brugada Syndrome/genetics , Brugada Syndrome/physiopathology , Electrocardiography , Humans , Long QT Syndrome/complications , Long QT Syndrome/genetics , Long QT Syndrome/physiopathology , Male , Mutation , NAV1.5 Voltage-Gated Sodium Channel/genetics , Phenotype , Ventricular Fibrillation/etiology
6.
Am J Cardiol ; 112(3): 363-8, 2013 Aug 01.
Article in English | MEDLINE | ID: mdl-23623047

ABSTRACT

Coronary plaques can be reduced by some medications. The aim of this study was to compare the effects of 2 angiotensin II receptor blockers (olmesartan at 20 mg/day or valsartan at 80 mg/day) on coronary plaque by coronary intravascular ultrasound. One hundred hypertensive patients with stable angina pectoris who underwent elective percutaneous coronary intervention were randomly selected to receive 1 of the 2 angiotensin II receptor blockers after coronary intervention. Nontarget coronary lesions with mild to moderate stenosis were measured by volumetric intravascular ultrasound at baseline and after 6 months. After 6 months, both the olmesartan and the valsartan groups showed significant reduction of the examined coronary plaque volume (46.2 ± 24.1 mm³ at baseline vs 41.6 ± 21.1 mm³ at 6 months: 4.7% decrease, p = 0.0002; and 47.2 ± 32.7 mm³ at baseline vs 42.5 ± 30.2 mm³ at 6 months: 4.8% decrease, p = 0.002, respectively). There was no statistically significant difference of plaque regression between the 2 groups (p = 0.96). In conclusion, there was a significant decrease from baseline in the coronary plaque volume in patients with stable angina pectoris who received olmesartan or valsartan for 6 months. In addition, there was no significant difference in the reduction of plaque volume achieved by these 2 medications.


Subject(s)
Angina Pectoris/diagnostic imaging , Angina Pectoris/therapy , Angioplasty, Balloon, Coronary , Angiotensin II Type 1 Receptor Blockers/therapeutic use , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Image Interpretation, Computer-Assisted , Imidazoles/therapeutic use , Tetrazoles/therapeutic use , Ultrasonography, Interventional , Valine/analogs & derivatives , Aged , Aged, 80 and over , Angiotensin II Type 1 Receptor Blockers/adverse effects , Combined Modality Therapy , Disease Progression , Double-Blind Method , Female , Humans , Hypertension/complications , Imidazoles/adverse effects , Long-Term Care , Male , Middle Aged , Tetrazoles/adverse effects , Valine/adverse effects , Valine/therapeutic use , Valsartan
7.
Int J Cardiol ; 162(2): 123-8, 2013 Jan 10.
Article in English | MEDLINE | ID: mdl-21636151

ABSTRACT

BACKGROUND: Cardiorespiratory fitness (CRF) can predict future cardiovascular disease. Rupture of vulnerable plaque which often has a large lipid core with a thin fibrous cap causes acute coronary syndrome including sudden cardiac death. We tested our hypothesis that preserved CRF is associated with low lipid composition and thick fibrous cap thickness of coronary lesions. METHODS: We prospectively performed both integrated backscatter intravascular ultrasound (IB-IVUS) and optical coherence tomography (OCT) for 77 non-culprit coronary lesions in 77 consecutive angina pectoris patients who underwent percutaneous coronary intervention (PCI). Percentage of achieved of predicted peak oxygen consumption (%PPeak Vo(2)) calculated based on measured peak Vo(2) using a cardiopulmonary exercise test performed post PCI was adapted as an indicator of patient CRF. RESULTS: Patients were divided into two groups [those with preserved CRF (%PPeak Vo(2) >82%) (Group I) or others (Group II)]. Coronary plaques of Group I patients had significantly smaller lipid volume, greater fibrous volume, and thicker fibrous cap thickness than those of Group II (32 ± 14% vs. 45 ± 13%, p<0.001; 57 ± 11% vs. 49 ± 11%, p<0.001; and 177.7 ± 20.9 µm vs. 143.7 ± 36.9 µm, p<0.001). In multivariate linear regression analysis, %PPeak Vo(2) showed a significantly negative correlation with lipid volume and a positive correlation with fibrous volume and fibrous cap thickness (ß=-0.418, p=0.001; ß=0.361, p=0.006; and ß=0.339, p=0.008). CONCLUSIONS: High %PPeak Vo(2) was associated with low lipid volume, high fibrous volume and thick fibrous cap thickness in coronary lesions. These results may well suggest an attenuated risk of cardiovascular events in patients with preserved CRF.


Subject(s)
Coronary Artery Disease/diagnosis , Coronary Vessels/pathology , Plaque, Atherosclerotic/diagnosis , Aged , Cardiac Output , Coronary Artery Disease/blood , Coronary Artery Disease/diagnostic imaging , Coronary Vessels/diagnostic imaging , Exercise Test , Female , Fibrosis/pathology , Humans , Lipids/blood , Male , Middle Aged , Physical Fitness , Plaque, Atherosclerotic/blood , Plaque, Atherosclerotic/diagnostic imaging , Prospective Studies , Tomography, Optical Coherence , Ultrasonography, Interventional/methods
8.
Am J Cardiol ; 109(8): 1131-6, 2012 Apr 15.
Article in English | MEDLINE | ID: mdl-22245411

ABSTRACT

It is well known that chronic kidney disease is a risk factor for atherosclerosis. The present study was conducted to identify any relation between the estimated glomerular filtration rate (eGFR) and coronary plaque characteristics using integrated backscatter intravascular ultrasound (IB-IVUS), which can detect coronary plaque composition. We performed IB-IVUS for 201 consecutive patients undergoing percutaneous coronary intervention, and they were divided into 3 groups according to the eGFR values (group 1 [n = 20], ≥90 ml/min/1.73 m(2); group 2 [n = 123], 60 to 90 ml/min/1.73 m(2); and group 3 [n = 58], <60 ml/min/1.73 m(2)). Coronary plaques in nonculprit lesions on 3-dimensional analysis were evaluated using IB-IVUS. The baseline characteristics were similar, except for older age and a greater prevalence of men in group 3. IB-IVUS showed a percentage of lipid volume of 44.7 ± 5.0% in group 1, 53.6 ± 6.2% in group 2, and 63.5 ± 6.2% in group 3 (p <0.01), with a corresponding percentage of fibrous volume of 53.9 ± 4.9%, 45.1 ± 6.0%, and 35.3 ± 6.1%, respectively (p <0.01). The eGFR correlated significantly with both parameters (r = -0.68, p <0.001 and r = 0.68, p <0.001, respectively). In conclusion, lower eGFR levels were associated with greater lipid and lower fibrous contents, contributing to coronary plaque vulnerability.


Subject(s)
Coronary Vessels/diagnostic imaging , Glomerular Filtration Rate , Plaque, Atherosclerotic/diagnostic imaging , Age Factors , Aged , Angioplasty, Balloon, Coronary , Coronary Angiography , Coronary Artery Disease/therapy , Female , Humans , Imaging, Three-Dimensional , Lipids/analysis , Male , Middle Aged , Multivariate Analysis , Prospective Studies , Sex Factors , Ultrasonography, Interventional
9.
Circ J ; 75(8): 1960-7, 2011.
Article in English | MEDLINE | ID: mdl-21646726

ABSTRACT

BACKGROUND: A high low-density lipoprotein cholesterol (LDL-C) to a high-density lipoprotein cholesterol (HDL-C) ratio is associated with cardiac events, while the left main coronary artery (LMCA) is considered to be an important target of atherosclerotic plaque accumulation. This aim of the present study was to investigate the relationship between a LDL-C/HDL-C ratio and the characteristics of tissue components of LMCA plaque. METHODS AND RESULTS: One-hundred-twenty consecutive patients with stable angina pectoris who received chronic statin treatment underwent percutaneous coronary intervention for the left coronary artery. We prospectively performed integrated backscatter (IB) intravascular ultrasound (IVUS) to their LMCAs and evaluated the tissue characteristics. According to the median value of their LDL-C/HDL-C ratios (2.4), they were divided into 2 groups [high LDL-C/HDL-C ratio (>2.4) (n=60) or low LDL-C/HDL-C ratio (≤ 2.4) (n=60)]. There was no significant difference in the data analyzed using conventional IVUS between the 2 groups. In the IB-IVUS analysis, patients with a high LDL-C/HDL-C ratio had a larger lipid volume and a smaller fibrous volume compared to patients with a low LDL-C/HDL-C ratio (52 ± 10% vs. 48 ± 10%, P=0.014 and 45 ± 9% vs. 50 ± 10%, P=0.010). CONCLUSIONS: A high LDL-C/HDL-C ratio was associated with a high percentage of lipid volume and a low percentage of fibrous volume in LMCA lesions. Our findings might well suggest the increased risk of cardiovascular events in patients with a high LDL-C/HDL-C ratio.


Subject(s)
Cholesterol, HDL/blood , Cholesterol, LDL/blood , Coronary Vessels/ultrastructure , Plaque, Atherosclerotic/blood , Plaque, Atherosclerotic/diagnostic imaging , Ultrasonography, Interventional , Aged , Angina Pectoris/blood , Angina Pectoris/surgery , Angioplasty , Coronary Vessels/surgery , Female , Humans , Male , Middle Aged