Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Entropy (Basel) ; 21(2)2019 Feb 18.
Article in English | MEDLINE | ID: mdl-33266906

ABSTRACT

Owing to its relatively high heat transfer performance and simple configurations, liquid cooling remains the preferred choice for electronic cooling and other applications. In this cooling approach, channel design plays an important role in dictating the cooling performance of the heat sink. Most cooling channel studies evaluate the performance in view of the first thermodynamics aspect. This study is conducted to investigate flow behaviour and heat transfer performance of an incompressible fluid in a cooling channel with oblique fins with regards to first law and second law of thermodynamics. The effect of oblique fin angle and inlet Reynolds number are investigated. In addition, the performance of the cooling channels for different heat fluxes is evaluated. The results indicate that the oblique fin channel with 20° angle yields the highest figure of merit, especially at higher Re (250-1000). The entropy generation is found to be lowest for an oblique fin channel with 90° angle, which is about twice than that of a conventional parallel channel. Increasing Re decreases the entropy generation, while increasing heat flux increases the entropy generation.

2.
Sci Total Environ ; 481: 317-34, 2014 May 15.
Article in English | MEDLINE | ID: mdl-24607396

ABSTRACT

Diesel engine is widely used in underground mining machines due to its efficiency, ease of maintenance, reliability and durability. However, it possesses significant danger to the miners and mining operations as it releases hazardous gases (CO, NO, CO2) and fine particles which can be easily inhaled by the miners. Moreover, the diesel engine consumes significant amount of oxygen which can lead to insufficient oxygen supply for miners. It is therefore critical to maintain sufficient oxygen supply while keeping hazardous gas concentrations from diesel emission below the maximum allowable level. The objective of this study is to propose and to examine various innovative ventilation strategies to control oxygen and hazardous gas concentrations in underground mine to ensure safety, productivity and cost related to energy consumption. Airflow distribution, oxygen and hazardous gas dispersion as well as ambient temperature within the mining area are evaluated by utilizing the well-established computational fluid dynamics (CFD) approach. The results suggest that our newly proposed ventilation design performs better as compared to the conventional design to handle hazardous gases from diesel emission.


Subject(s)
Air Pollutants, Occupational/analysis , Hazardous Substances/analysis , Inhalation Exposure/prevention & control , Occupational Exposure/prevention & control , Air Pollutants/analysis , Inhalation Exposure/statistics & numerical data , Mining , Occupational Exposure/statistics & numerical data , Vehicle Emissions/analysis , Ventilation/methods
3.
J Funct Biomater ; 2(3): 195-212, 2011 Aug 25.
Article in English | MEDLINE | ID: mdl-24956303

ABSTRACT

This computational study investigates the sensing and actuating behavior of a pH-sensitive hydrogel-based microfluidic flow controller. This hydrogel-based flow controller has inherent advantage in its unique stimuli-sensitive properties, removing the need for an external power supply. The predicted swelling behavior the hydrogel is validated with steady-state and transient experiments. We then demonstrate how the model is implemented to study the sensing and actuating behavior of hydrogels for different microfluidic flow channel/hydrogel configurations: e.g., for flow in a T-junction with single and multiple hydrogels. In short, the results suggest that the response of the hydrogel-based flow controller is slow. Therefore, two strategies to improve the response rate of the hydrogels are proposed and demonstrated. Finally, we highlight that the model can be extended to include other stimuli-responsive hydrogels such as thermo-, electric-, and glucose-sensitive hydrogels.

SELECTION OF CITATIONS
SEARCH DETAIL
...