Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Environ Sci Technol ; 48(23): 13985-91, 2014 Dec 02.
Article in English | MEDLINE | ID: mdl-25350948

ABSTRACT

Plutonium (Pu), americium (Am), and curium (Cm) activities were measured in sediments from a former radioactive waste disposal basin located on the Savannah River Site, South Carolina, and in subsurface aquifer sediments collected downgradient from the basin. In situ Kd values (Pu concentration ratio of sediment/groundwater) derived from this field data and previously reported groundwater concentration data compared well to laboratory Kd values reported in the literature. Pu isotopic signatures confirmed multiple sources of Pu contamination. The ratio of (240)Pu/(239)Pu was appreciably lower for sediment samples compared to the associated groundwater. This isotopic ratio difference may be explained by the following: (1) (240)Pu produced by decay of (244)Cm may exist predominantly in high oxidation states (Pu(V)O2(+) and Pu(VI)O2(2+)) compared to Pu derived from the disposed waste effluents, and (2) oxidized forms of Pu sorb less to sediments than reduced forms of Pu. Isotope-specific Kd values calculated from measured Pu activities in the sediments and groundwater indicated that (240)Pu, which is derived primarily from the decay of (244)Cm, had a value of 10 ± 2 mL g(-1), whereas (239)Pu originating from the waste effluents discharged at the site had a value of 101 ± 8 mL g(-1). One possible explanation for the isotope-specific sorption behavior is that (240)Pu likely existed in the weaker sorbing oxidation states, +5 or +6, than (239)Pu, which likely existed in the +3 or +4 oxidation states. Consequently, remediation strategies for radioactively contaminated systems must consider not only the discharged contaminants but also their decay products. In this case, mitigation of Cm as well as Pu will be required to completely address Pu migration from the source term.


Subject(s)
Americium/chemistry , Curium/chemistry , Plutonium/chemistry , Radioactive Waste/analysis , Radioisotopes , Water Pollutants, Radioactive/chemistry , Environmental Monitoring , Oxidation-Reduction , Rivers/chemistry , Soil Pollutants, Radioactive/chemistry , South Carolina
2.
Appl Radiat Isot ; 66(6-7): 835-40, 2008.
Article in English | MEDLINE | ID: mdl-18359232

ABSTRACT

A workshop was held from 28 February to 2 March 2006 at the National Institute of Standards and Technology (NIST) to evaluate the needs for new directions for complex matrix reference materials certified for radionuclide content, interlaboratory comparisons and performance evaluation (PE) programs. The workshop identified new radioanalytical metrology thrust areas needed for environmental, radiobioassay, emergency consequence management, and nuclear forensics, attribution, nonproliferation, and safeguards.

SELECTION OF CITATIONS
SEARCH DETAIL
...