Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Lab Chip ; 13(24): 4784-93, 2013 Dec 21.
Article in English | MEDLINE | ID: mdl-24154831

ABSTRACT

In this paper, we demonstrate recordings of the ion channel activity across the cell membrane in a biological cell by employing the so-called patch clamping technique on an injection-molded polymer microfluidic device. The findings will allow direct recordings of ion channel activity to be made using the cheapest materials and production platform to date and with the potential for very high throughput. The employment of cornered apertures for cell capture allowed the fabrication of devices without through holes and via a scheme comprising master origination by dry etching in a silicon substrate, electroplating in nickel and injection molding of the final part. The most critical device parameters were identified as the length of the patching capillary and the very low surface roughness on the inside of the capillary. The cross-sectional shape of the orifice was found to be less critical, as both rectangular and semicircular profiles seemed to have almost the same ability to form tight seals with cells with negligible leak currents. The devices were functionally tested using human embryonic kidney cells expressing voltage-gated sodium channels (Nav1.7) and benchmarked against a commercial state-of-the-art system for automated ion channel recordings. These experiments considered current-voltage (IV) relationships for activation and inactivation of the Nav1.7 channels and their sensitivity to a local anesthetic, lidocaine. Both IVs and lidocaine dose-response curves obtained from the injection-molded polymer device were in good agreement with data obtained from the commercial system.


Subject(s)
Microfluidic Analytical Techniques/instrumentation , NAV1.7 Voltage-Gated Sodium Channel/metabolism , Equipment Design , HEK293 Cells , Humans , Injections , Sodium/metabolism
2.
Assay Drug Dev Technol ; 1(5): 685-93, 2003 Oct.
Article in English | MEDLINE | ID: mdl-15090241

ABSTRACT

Planar silicon chips with 1-2-microm etched holes (average resistance: 2.04 +/- 0.02 MOmega in physiological buffer, n = 274) have been developed for patch-clamp recordings of whole-cell currents from cells in suspension. An automated 16-channel parallel screening system, QPatch 16, has been developed using this technology. A single-channel prototype of the QPatch system was used for validation of the patch-clamp chip technology. We present here data on the quality of patch-clamp recordings and from actual drug screening studies of human potassium channels expressed in cultured cell lines. Using Chinese hamster ovary (CHO) and human embryonic kidney cells (HEK), gigaseals of 4.1 +/- 0.4 GOmega (n = 146) and high-quality whole-cell current recordings were obtained from hERG and KCNQ4 potassium channels. Success rates for gigaseal recordings varied from 40 to 95%, and 67% of the whole-cell configurations lasted for >20 min. Cells were maintained in suspension up to 4 h in a cell storage facility that is integrated in the QPatch 16. No decline in patchability was observed during this time course. A series of screens was conducted with known inhibitors of the hERG and KCNQ4 potassium channels. Dose-response relationship characterizations of verapamil and rBeKm-1 blockage of hERG currents provided IC(50) values similar to values reported in the literature.


Subject(s)
Cell Culture Techniques/instrumentation , Drug Evaluation, Preclinical/instrumentation , Membrane Potentials/physiology , Patch-Clamp Techniques/instrumentation , Potassium Channels/physiology , Robotics/instrumentation , Animals , Biotechnology/instrumentation , Biotechnology/methods , CHO Cells , Cell Culture Techniques/methods , Cells, Cultured , Cricetinae , Cricetulus , Dose-Response Relationship, Drug , Drug Evaluation, Preclinical/methods , Electrophysiology/instrumentation , Electrophysiology/methods , Equipment Design , Equipment Failure Analysis , Feasibility Studies , Humans , Ion Channel Gating/drug effects , Ion Channel Gating/physiology , Kidney/drug effects , Kidney/physiology , Membrane Potentials/drug effects , Microelectrodes , Patch-Clamp Techniques/methods , Potassium Channel Blockers/pharmacology , Potassium Channels/drug effects , Reproducibility of Results , Robotics/methods , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...