Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Biosens Bioelectron ; 258: 116358, 2024 Aug 15.
Article in English | MEDLINE | ID: mdl-38718634

ABSTRACT

Wearable sensors for sweat glucose monitoring are gaining massive interest as a patient-friendly and non-invasive way to manage diabetes. The present work offers an alternative on-body method employing an all-printed flexible electrochemical sensor to quantify the amount of glucose in human sweat. The working electrode of the glucose sensor was printed using a custom-formulated ink containing multi-walled carbon nanotube (MWCNT), poly (3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOPT: PSS), and iron (II, III) oxide (Fe3O4) nanoparticles. This novel ink composition has good conductivity, enhanced catalytic activity, and excellent selectivity. The working electrode was modified using Prussian blue (PB) nanoparticles and glucose oxidase enzyme (GOx). The sensor displayed a linear chronoamperometric response to glucose from 1 µM to 400 µM, with a precise detection limit of ∼0.38 µM and an impressive sensitivity of ∼4.495 µAµM-1cm-2. The sensor stored at 4 °C exhibited excellent stability over 60 days, high selectivity, and greater reproducibility. The glucose detection via the standard addition method in human sweat samples acquired a high recovery rate of 96.0-98.6%. Examining human sweat during physical activity also attested to the biosensor's real-time viability. The results also show an impressive correlation between glucose levels obtained from a commercial blood glucose meter and sweat glucose concentrations. Remarkably, the present results outperform previously published printed glucose sensors in terms of detection range, low cost, ease of manufacturing, stability, selectivity, and wearability.


Subject(s)
Biosensing Techniques , Glucose Oxidase , Glucose , Limit of Detection , Nanocomposites , Nanotubes, Carbon , Sweat , Wearable Electronic Devices , Humans , Biosensing Techniques/instrumentation , Nanotubes, Carbon/chemistry , Sweat/chemistry , Nanocomposites/chemistry , Glucose/analysis , Glucose Oxidase/chemistry , Ink , Electrochemical Techniques , Ferric Compounds/chemistry , Ferrocyanides/chemistry , Polymers/chemistry , Reproducibility of Results , Bridged Bicyclo Compounds, Heterocyclic/chemistry , Polystyrenes
2.
ACS Appl Mater Interfaces ; 14(41): 46775-46788, 2022 Oct 19.
Article in English | MEDLINE | ID: mdl-36196480

ABSTRACT

Silver nanoparticles of average size 12-13 nm were successfully decorated on the surface of multiwalled carbon nanotubes (MWCNTs) through a scalable wet chemical method without altering the structure of the MWCNTs. Employing this Ag@MWCNT, a multifunctional room-temperature curable conductive ink was developed, with PEDOT:PSS as the conductive binder. Screen printing of the ink could yield conductive planar traces with a 9.5 µm thickness and a conductivity of 28.99 S/cm, minimal surface roughness, and good adhesion on Mylar and Kapton. The versatility of the ink for developing functional elements for printed electronics was demonstrated by fabricating prototypes of a wearable strain sensor, a smart glove, a wearable heater, and a wearable breath sensor. The printed strain sensor exhibited a massive sensing range for wearable applications, including an impressive 1332% normalized resistance change under a maximum stretchability of 23% with superior cyclic stability up to 10 000 cycles. The sensor also exhibited an impeccable gauge factor of 142 for a 5% strain (59 for 23%). Furthermore, the sensor was integrated into a smart glove that could flawlessly replicate a human finger's gestures with a minimal response time of 225-370 ms. Piezoresistive vibration sensors were also fabricated by printing the ink on Mylar, which was employed to fabricate a smart mask and a smart wearable patch to monitor variations in human respiratory and pulmonary cycles. Finally, an energy-efficient flexible heater was fabricated using the developed ink. The heater could generate a uniform temperature distribution of 130 °C at the expense of only 393 mW/cm2 and require a minimum response time of 20 s. Thus, the unique formulation of Ag@MWCNT ink proved suitable for versatile devices for future wearable applications.


Subject(s)
Metal Nanoparticles , Nanotubes, Carbon , Wearable Electronic Devices , Humans , Silver/chemistry , Metal Nanoparticles/chemistry , Ink
SELECTION OF CITATIONS
SEARCH DETAIL
...