Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 17 de 17
Filter
1.
Cartilage ; : 19476035241247297, 2024 Apr 23.
Article in English | MEDLINE | ID: mdl-38651510

ABSTRACT

OBJECTIVE: The osteochondral allograft procedure uses grafts constructed larger than the recipient site to stabilize the graft, in what is known as the press-fit technique. This research aims to characterize the relationships between press-fit size, insertion forces, and cell viability in ovine and human osteochondral tissue. DESIGN: Human (4 donors) and ovine (5 animals) articular joints were used to harvest osteochondral grafts (4.55 mm diameter, N = 33 Human, N = 35 Ovine) and create recipient sites with grafts constructed to achieve varying degrees of press fit (0.025-0.240 mm). Donor grafts were inserted into recipient sites while insertion forces were measured followed by quantification of chondrocyte viability and histological staining to evaluate the extracellular matrix. RESULTS: Both human and ovine tissues exhibited similar mechanical and cellular responses to changes in press-fit. Insertion forces (Human: 3-169 MPa, Ovine: 36-314 MPa) and cell viability (Human: 16%-89% live, Ovine: 2%-76% live) were correlated to press-fit size for both human (force: r = 0.539, viability: r = -0.729) and ovine (force: r = 0.655, viability: r = -0.714) tissues. In both species, a press-fit above 0.14 mm resulted in reduced cell viability below a level acceptable for transplantation, increased insertion forces, and reduced linear correlation to press-fit size compared to samples with a press-fit below 0.14 mm. CONCLUSIONS: Increasing press-fit size required increased insertion forces and resulted in reduced cell viability. Ovine and human osteochondral tissues responded similarly to impact insertion and varying press-fit size, providing evidence for the use of the ovine model in allograft-related research.

2.
Bone Joint J ; 101-B(1_Supple_A): 46-52, 2019 Jan.
Article in English | MEDLINE | ID: mdl-30648496

ABSTRACT

AIMS: The aim of this study was to report the outcome of femoral condylar fresh osteochondral allografts (FOCA) with concomitant realignment osteotomy with a focus on graft survivorship, complications, reoperation, and function. PATIENTS AND METHODS: We identified 60 patients (16 women, 44 men) who underwent unipolar femoral condylar FOCA with concomitant realignment between 1972 and 2012. The mean age of the patients was 28.9 years (10 to 62) and the mean follow-up was 11.4 years (2 to 35). Failure was defined as conversion to total knee arthroplasty, revision allograft, or graft removal. Clinical outcome was evaluated using the modified Hospital for Special Surgery (mHSS) score. RESULTS: A total of 14 grafts (23.3%) failed at a mean of 8.6 years (1.4 to 20.1). Graft survivorship was 87.3% (95% confidence interval (CI) 79.0 to 96.6), 85.0% (95% CI 75.8 to 95.3), 74.8% (95% CI 62.2 to 90.0), 65.2% (95% CI 49.9 to 85.2), and 59.8% (95% CI 43.5 to 82.1) at five, ten, 15, 20, and 25 years, respectively. A total of 23 patients (38.3%) developed complications, and 26 (43.3%) had a further operation. Persistent postoperative malalignment occurred more frequently in failed grafts (28.6% vs 4.3%; p = 0.023), and was a risk factor for graft failure (hazard ratio 6.55; 95% CI 1.61 27.71; p = 0.009). The mean mHSS score improved from 74.1 (40 to 91) preoperatively to 89.0 (66 to 100) at final follow-up (p < 0.001). CONCLUSION: Femoral condylar FOCA with concomitant realignment osteotomy provides excellent long-term graft survival and reliable functional improvement. Persistent malalignment may increase the risk for graft failure.


Subject(s)
Bone Malalignment/surgery , Bone Transplantation/methods , Cartilage, Articular/surgery , Knee Injuries/surgery , Knee Joint/surgery , Osteotomy/methods , Adolescent , Adult , Bone Malalignment/diagnostic imaging , Bone Transplantation/adverse effects , Child , Female , Femur/transplantation , Follow-Up Studies , Graft Survival , Humans , Kaplan-Meier Estimate , Knee Injuries/diagnostic imaging , Knee Joint/diagnostic imaging , Male , Middle Aged , Osteotomy/adverse effects , Postoperative Complications , Radiography , Reoperation/methods , Reoperation/statistics & numerical data , Retrospective Studies , Treatment Outcome , Young Adult
3.
Exp Oncol ; 40(4): 332-335, 2018 Dec.
Article in English | MEDLINE | ID: mdl-30593758

ABSTRACT

AIM: To describe the case of rare benign lymphoproliferative disorder - pulmonary nodular lymphoid hyperplasia in the patient with previous pulmonary tuberculosis. MATERIALS AND METHODS: In the case of pulmonary nodular lymphoid hyperplasia clinical, laboratory, instrumental and morphological examination was performed. RESULTS: 44-year-old woman in 7 years after successfully treated infiltrative drug-susceptible tuberculosis of the right lung, was hospitalized with a suspected tumor of the left lung root. The patient underwent left-sided pneumonectomy with lymph nodes dissection. The results of histopathological and immunohistochemical studies evidenced on nodular lymphoid hyperplasia of the left lung. CONCLUSION: Pulmonary nodular lymphoid hyperplasia is a rare lymphoproliferative disorder of the lung with favorable prognosis. For the purpose of differential diagnosis, it is necessary to apply immunohistochemistry.


Subject(s)
Lung/pathology , Lymphoproliferative Disorders/diagnosis , Tuberculosis, Pulmonary , Adult , Diagnosis, Differential , Female , Humans , Hyperplasia/etiology , Lung/diagnostic imaging , Lung Diseases/diagnostic imaging , Lung Diseases/pathology , Lymph Nodes/pathology , Lymphoproliferative Disorders/diagnostic imaging , Lymphoproliferative Disorders/etiology
4.
Bone Joint J ; 99-B(5): 607-613, 2017 May.
Article in English | MEDLINE | ID: mdl-28455469

ABSTRACT

AIMS: It may not be possible to undertake revision total hip arthroplasty (THA) in the presence of massive loss of acetabular bone stock using standard cementless hemispherical acetabular components and metal augments, as satisfactory stability cannot always be achieved. We aimed to study the outcome using a reconstruction cage and a porous metal augment in these patients. PATIENTS AND METHODS: A total of 22 acetabular revisions in 19 patients were performed using a combination of a reconstruction cage and porous metal augments. The augments were used in place of structural allografts. The mean age of the patients at the time of surgery was 70 years (27 to 85) and the mean follow-up was 39 months (27 to 58). The mean number of previous THAs was 1.9 (1 to 3). All patients had segmental defects involving more than 50% of the acetabulum and seven hips had an associated pelvic discontinuity. RESULTS: Three failures were observed in two hips, both of which had undergone a previous resection of a tumour affecting the acetabulum. Other complications included a late arterial injury, a sciatic nerve palsy, a dislocation treated with a femoral revision, a deep infection treated with irrigation and debridement and a fracture of the greater trochanter treated conservatively. The mean Oxford Hip Score significantly increased from 13.9 (2 to 23) to 28.7 (13 to 38) (p < 0.00001). The mean vertical distance between the centre of rotation of the hip and its normal location decreased from 30 mm to 10 mm. CONCLUSIONS: Acceptable early survivorship can be achieved using this novel technique, but it may be unsuitable for use in patients who have previously undergone the resection of a tumour involving the acetabulum. Cite this article: Bone Joint J 2017;99-B:607-13.


Subject(s)
Acetabulum/surgery , Arthroplasty, Replacement, Hip/methods , Bone Transplantation/methods , Acetabulum/diagnostic imaging , Adult , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip/instrumentation , Female , Hip Prosthesis , Humans , Internal Fixators , Kaplan-Meier Estimate , Male , Metals , Middle Aged , Osteotomy/methods , Porosity , Prosthesis Design , Radiography , Reoperation/instrumentation , Reoperation/methods , Retrospective Studies
6.
Bone Joint J ; 98-B(1 Suppl A): 73-7, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26733646

ABSTRACT

An uncemented hemispherical acetabular component is the mainstay of acetabular revision and gives excellent long-term results. Occasionally, the degree of acetabular bone loss means that a hemispherical component will be unstable when sited in the correct anatomical location or there is minimal bleeding host bone left for biological fixation. On these occasions an alternative method of reconstruction has to be used. A major column structural allograft has been shown to restore the deficient bone stock to some degree, but it needs to be off-loaded with a reconstruction cage to prevent collapse of the graft. The use of porous metal augments is a promising method of overcoming some of the problems associated with structural allograft. If the defect is large, the augment needs to be protected by a cage to allow ingrowth to occur. Cup-cage reconstruction is an effective method of treating chronic pelvic discontinuity and large contained or uncontained bone defects. This paper presents the indications, surgical techniques and outcomes of various methods which use acetabular reconstruction cages for revision total hip arthroplasty.


Subject(s)
Acetabulum/surgery , Arthroplasty, Replacement, Hip/instrumentation , Arthroplasty, Replacement, Hip/methods , Bone Diseases/surgery , Bone Transplantation , Humans , Reoperation , Severity of Illness Index
8.
Bone Joint J ; 97-B(8): 1050-5, 2015 Aug.
Article in English | MEDLINE | ID: mdl-26224820

ABSTRACT

This study reports the clinical outcome of reconstruction of deficient abductor muscles following revision total hip arthroplasty (THA), using a fresh-frozen allograft of the extensor mechanism of the knee. A retrospective analysis was conducted of 11 consecutive patients with a severe limp because of abductor deficiency which was confirmed on MRI scans. The mean age of the patients (three men and eight women) was 66.7 years (52 to 84), with a mean follow-up of 33 months (24 to 41). Following surgery, two patients had no limp, seven had a mild limp, and two had a persistent severe limp (p = 0.004). The mean power of the abductors improved on the Medical Research Council scale from 2.15 to 3.8 (p < 0.001). Pre-operatively, all patients required a stick or walking frame; post-operatively, four patients were able to walk without an aid. Overall, nine patients had severe or moderate pain pre-operatively; ten patients had no or mild pain post-operatively. At final review, the Harris hip score was good in five patients, fair in two and poor in four. We conclude that using an extensor mechanism allograft is relatively effective in the treatment of chronic abductor deficiency of the hip after THA when techniques such as local tissue transfer are not possible. Longer-term follow-up is necessary before the technique can be broadly applied.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Muscle, Skeletal/transplantation , Plastic Surgery Procedures/methods , Postoperative Complications/surgery , Aged , Aged, 80 and over , Allografts , Female , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Pain Measurement , Pain, Postoperative , Quality of Life , Reoperation , Retrospective Studies , Treatment Outcome
10.
Bone Joint J ; 96-B(11 Supple A): 11-6, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25381401

ABSTRACT

Cartilage defects of the hip cause significant pain and may lead to arthritic changes that necessitate hip replacement. We propose the use of fresh osteochondral allografts as an option for the treatment of such defects in young patients. Here we present the results of fresh osteochondral allografts for cartilage defects in 17 patients in a prospective study. The underlying diagnoses for the cartilage defects were osteochondritis dissecans in eight and avascular necrosis in six. Two had Legg-Calve-Perthes and one a femoral head fracture. Pre-operatively, an MRI was used to determine the size of the cartilage defect and the femoral head diameter. All patients underwent surgical hip dislocation with a trochanteric slide osteotomy for placement of the allograft. The mean age at surgery was 25.9 years (17 to 44) and mean follow-up was 41.6 months (3 to 74). The mean Harris hip score was significantly better after surgery (p<0.01) and 13 patients had fair to good outcomes. One patient required a repeat allograft, one patient underwent hip replacement and two patients are awaiting hip replacement. Fresh osteochondral allograft is a reasonable treatment option for hip cartilage defects in young patients.


Subject(s)
Bone Transplantation/methods , Cartilage, Articular/surgery , Osteochondritis Dissecans/surgery , Osteotomy/methods , Plastic Surgery Procedures/methods , Adolescent , Adult , Aged , Aged, 80 and over , Allografts , Cartilage, Articular/diagnostic imaging , Cartilage, Articular/pathology , Female , Follow-Up Studies , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Osteochondritis Dissecans/diagnosis , Prospective Studies , Radiography , Treatment Outcome , Young Adult
11.
Bone Joint J ; 96-B(8): 1029-34, 2014 Aug.
Article in English | MEDLINE | ID: mdl-25086117

ABSTRACT

The purpose of this study was to identify factors that predict implant cut-out after cephalomedullary nailing of intertrochanteric and subtrochanteric hip fractures, and to test the significance of calcar referenced tip-apex distance (CalTAD) as a predictor for cut-out. We retrospectively reviewed 170 consecutive fractures that had undergone cephalomedullary nailing. Of these, 77 met the inclusion criteria of a non-pathological fracture with a minimum of 80 days radiological follow-up (mean 408 days; 81 days to 4.9 years). The overall cut-out rate was 13% (10/77). The significant parameters in the univariate analysis were tip-apex distance (TAD) (p < 0.001), CalTAD (p = 0.001), cervical angle difference (p = 0.004), and lag screw placement in the anteroposterior (AP) view (Parker's ratio index) (p = 0.003). Non-significant parameters were age (p = 0.325), gender (p = 1.000), fracture side (p = 0.507), fracture type (AO classification) (p = 0.381), Singh Osteoporosis Index (p = 0.575), lag screw placement in the lateral view (p = 0.123), and reduction quality (modified Baumgaertner's method) (p = 0.575). In the multivariate analysis, CalTAD was the only significant measurement (p = 0.001). CalTAD had almost perfect inter-observer reliability (interclass correlation coefficient (ICC) 0.901). Our data provide the first reported clinical evidence that CalTAD is a predictor of cut-out. The finding of CalTAD as the only significant parameter in the multivariate analysis, along with the univariate significance of Parker's ratio index in the AP view, suggest that inferior placement of the lag screw is preferable to reduce the rate of cut-out.


Subject(s)
Fracture Fixation, Intramedullary/methods , Hip Fractures/surgery , Adult , Aged , Aged, 80 and over , Bone Nails , Bone Screws , Equipment Failure , Female , Fracture Fixation, Intramedullary/instrumentation , Humans , Male , Middle Aged , Multivariate Analysis , Observer Variation , Retrospective Studies , Young Adult
12.
Bone Joint J ; 96-B(3): 319-24, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24589785

ABSTRACT

We retrospectively reviewed 44 consecutive patients (50 hips) who underwent acetabular re-revision after a failed previous revision that had been performed using structural or morcellised allograft bone, with a cage or ring for uncontained defects. Of the 50 previous revisions, 41 cages and nine rings were used with allografts for 14 minor-column and 36 major-column defects. We routinely assessed the size of the acetabular bone defect at the time of revision and re-revision surgery. This allowed us to assess whether host bone stock was restored. We also assessed the outcome of re-revision surgery in these circumstances by means of radiological characteristics, rates of failure and modes of failure. We subsequently investigated the factors that may affect the potential for the restoration of bone stock and the durability of the re-revision reconstruction using multivariate analysis. At the time of re-revision, there were ten host acetabula with no significant defects, 14 with contained defects, nine with minor-column, seven with major-column defects and ten with pelvic discontinuity. When bone defects at re-revision were compared with those at the previous revision, there was restoration of bone stock in 31 hips, deterioration of bone stock in nine and remained unchanged in ten. This was a significant improvement (p < 0.001). Morselised allografting at the index revision was not associated with the restoration of bone stock. In 17 hips (34%), re-revision was possible using a simple acetabular component without allograft, augments, rings or cages. There were 47 patients with a mean follow-up of 70 months (6 to 146) available for survival analysis. Within this group, the successful cases had a minimum follow-up of two years after re-revision. There were 22 clinical or radiological failures (46.7%), 18 of which were due to aseptic loosening. The five and ten year Kaplan-Meier survival rate was 75% (95% CI, 60 to 86) and 56% (95% CI, 40 to 70) respectively with aseptic loosening as the endpoint. The rate of aseptic loosening was higher for hips with pelvic discontinuity (p = 0.049) and less when the allograft had been in place for longer periods (p = 0.040). The use of a cage or ring over structural allograft bone for massive uncontained defects in acetabular revision can restore host bone stock and facilitate subsequent re-revision surgery to a certain extent.


Subject(s)
Acetabulum/pathology , Acetabulum/surgery , Arthroplasty, Replacement, Hip/adverse effects , Bone Transplantation/methods , Hip Prosthesis , Plastic Surgery Procedures/methods , Allografts , Female , Humans , Male , Osteotomy , Postoperative Complications , Reoperation , Retrospective Studies , Treatment Outcome
13.
Bone Joint J ; 96-B(2): 195-200, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24493184

ABSTRACT

The use of ilioischial cage reconstruction for pelvic discontinuity has been replaced by the Trabecular Metal (Zimmer, Warsaw, Indiana) cup-cage technique in our institution, due to the unsatisfactory outcome of using a cage alone in this situation. We report the outcome of 26 pelvic discontinuities in 24 patients (20 women and four men, mean age 65 years (44 to 84)) treated by the cup-cage technique at a mean follow-up of 82 months (12 to 113) and compared them with a series of 19 pelvic discontinuities in 19 patients (18 women and one man, mean age 70 years (42 to 86)) treated with a cage at a mean follow-up of 69 months (1 to 170). The clinical and radiological outcomes as well as the survivorship of the groups were compared. In all, four of the cup-cage group (15%) and 13 (68%) of the cage group failed due to septic or aseptic loosening. The seven-year survivorship was 87.2% (95% confidence interval (CI) 71 to 103) for the cup-cage group and 49.9% (95% CI 15 to 84) for the cage-alone group (p = 0.009). There were four major complications in the cup-cage group and nine in the cage group. Radiological union of the discontinuity was found in all successful cases in the cup-cage group and three of the successful cage cases. Three hips in the cup-cage group developed early radiological migration of the components, which stabilised with a successful outcome. Cup-cage reconstruction is a reliable technique for treating pelvic discontinuity in mid-term follow-up and is preferred to ilioischial cage reconstruction. If the continuity of the bone graft at the discontinuity site is not disrupted, early migration of the components does not necessarily result in failure.


Subject(s)
Acetabulum/surgery , Arthroplasty, Replacement, Hip/methods , Bone Transplantation/methods , Hip Prosthesis , Pelvic Bones/surgery , Plastic Surgery Procedures/methods , Adult , Aged , Aged, 80 and over , Female , Follow-Up Studies , Humans , Male , Middle Aged , Prosthesis Design , Prosthesis Failure , Retrospective Studies , Time Factors , Treatment Outcome
14.
Bone Joint J ; 95-B(6): 777-81, 2013 Jun.
Article in English | MEDLINE | ID: mdl-23723271

ABSTRACT

In this retrospective study we evaluated the proficiency of shelf autograft in the restoration of bone stock as part of primary total hip replacement (THR) for hip dysplasia, and in the results of revision arthroplasty after failure of the primary arthroplasty. Of 146 dysplastic hips treated by THR and a shelf graft, 43 were revised at an average of 156 months, 34 of which were suitable for this study (seven hips were excluded because of insufficient bone-stock data and two hips were excluded because allograft was used in the primary THR). The acetabular bone stock of the hips was assessed during revision surgery. The mean implant-bone contact was 58% (50% to 70%) at primary THR and 78% (40% to 100%) at the time of the revision, which was a significant improvement (p < 0.001). At primary THR all hips had had a segmental acetabular defect > 30%, whereas only five (15%) had significant segmental bone defects requiring structural support at the time of revision. In 15 hips (44%) no bone graft or metal augments were used during revision. A total of 30 hips were eligible for the survival study. At a mean follow-up of 103 months (27 to 228), two aseptic and two septic failures had occurred. Kaplan-Meier survival analysis of the revision procedures demonstrated a ten-year survival rate of 93.3% (95% confidence interval (CI) 78 to 107) with clinical or radiological failure as the endpoint. The mean Oxford hip score was 38.7 (26 to 46) for non-revised cases at final follow-up. Our results indicate that the use of shelf autografts during THR for dysplastic hips restores bone stock, contributing to the favourable survival of the revision arthroplasty should the primary procedure fail.


Subject(s)
Acetabulum/surgery , Arthroplasty, Replacement, Hip/methods , Bone Transplantation/methods , Hip Dislocation, Congenital/surgery , Reoperation/methods , Adult , Aged , Aged, 80 and over , Female , Follow-Up Studies , Hip Dislocation, Congenital/mortality , Humans , Male , Middle Aged , Ontario/epidemiology , Reoperation/mortality , Retrospective Studies , Survival Rate/trends , Transplantation, Autologous , Treatment Outcome
15.
J Bone Joint Surg Br ; 94(6): 762-7, 2012 Jun.
Article in English | MEDLINE | ID: mdl-22628589

ABSTRACT

The treatment of substantial proximal femoral bone loss in young patients with developmental dysplasia of the hip (DDH) is challenging. We retrospectively analysed the outcome of 28 patients (30 hips) with DDH who underwent revision total hip replacement (THR) in the presence of a deficient proximal femur, which was reconstructed with an allograft prosthetic composite. The mean follow-up was 15 years (8.5 to 25.5). The mean number of previous THRs was three (1 to 8). The mean age at primary THR and at the index reconstruction was 41 years (18 to 61) and 58.1 years (32 to 72), respectively. The indication for revision included mechanical loosening in 24 hips, infection in three and peri-prosthetic fracture in three. Six patients required removal and replacement of the allograft prosthetic composite, five for mechanical loosening and one for infection. The survivorship at ten, 15 and 20 years was 93% (95% confidence interval (CI) 91 to 100), 75.5% (95% CI 60 to 95) and 75.5% (95% CI 60 to 95), respectively, with 25, eight, and four patients at risk, respectively. Additionally, two junctional nonunions between the allograft and host femur required bone grafting and plating. An allograft prosthetic composite affords a good long-term outcome in the management of proximal femoral bone loss in revision THR in patients with DDH, while preserving distal host bone.


Subject(s)
Arthroplasty, Replacement, Hip/adverse effects , Bone Resorption/etiology , Bone Transplantation/methods , Hip Dislocation, Congenital/surgery , Hip Prosthesis , Adolescent , Adult , Arthroplasty, Replacement, Hip/instrumentation , Arthroplasty, Replacement, Hip/methods , Bone Resorption/surgery , Female , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Prosthesis Failure/etiology , Reoperation/adverse effects , Reoperation/methods , Retrospective Studies , Treatment Outcome , Young Adult
16.
J Bone Joint Surg Br ; 94(2): 158-62, 2012 Feb.
Article in English | MEDLINE | ID: mdl-22323678

ABSTRACT

We report the use of porous metal acetabular revision shells in the treatment of contained bone loss. The outcomes of 53 patients with ≤ 50% acetabular bleeding host bone contact were compared with a control group of 49 patients with > 50% to 85% bleeding host bone contact. All patients were treated with the same type of trabecular metal acetabular revision shell. The mean age at revision was 62.4 years (42 to 80) and the mean follow-up of both groups was 72.4 months (60 to 102). Clinical, radiological and functional outcomes were assessed. There were four (7.5%) mechanical failures in the ≤ 50% host bone contact group and no failures in the > 50% host bone contact group (p = 0.068). Out of both groups combined there were four infections (3.9%) and five recurrent dislocations (4.9%) with a stable acetabular component construct that were revised to a constrained liner. Given the complexity of the reconstructive challenge, porous metal revision acetabular shells show acceptable failure rates at five to ten years' follow-up in the setting of significant contained bone defects. This favourable outcome might be due to the improved initial stability achieved by a high coefficient of friction between the acetabular implant and the host bone, and the high porosity, which affords good bone ingrowth.


Subject(s)
Acetabulum/surgery , Arthroplasty, Replacement, Hip/methods , Hip Prosthesis , Acetabulum/diagnostic imaging , Adult , Aged , Aged, 80 and over , Female , Follow-Up Studies , Hemorrhage/etiology , Humans , Male , Metals/chemistry , Middle Aged , Porosity , Prosthesis Design , Prosthesis Failure , Radiography , Reoperation/instrumentation , Reoperation/methods , Treatment Outcome
17.
J Bone Joint Surg Br ; 93(5): 593-600, 2011 May.
Article in English | MEDLINE | ID: mdl-21511923

ABSTRACT

We conducted a systematic review and meta-analysis of randomised controlled trials comparing cross-linked with conventional polyethylene liners for total hip replacement in order to determine whether these liners reduce rates of wear, radiological evidence of osteolysis and the need for revision. The MEDLINE, EMBASE and COCHRANE databases were searched from their inception to May 2010 for all trials involving the use of cross-linked polyethylene in total hip replacement. Eligibility for inclusion in the review included the random allocation of treatments, the use of cross-linked and conventional polyethylene, and radiological wear as an outcome measure. The pooled mean differences were calculated for bedding-in, linear wear rate, three-dimensional linear wear rate, volumetric wear rate and total linear wear. Pooled risk ratios were calculated for radiological osteolysis and revision hip replacement. A search of the literature identified 194 potential studies, of which 12 met the inclusion criteria. All reported a significant reduction in radiological wear for cross-linked polyethylene. The pooled mean differences for linear rate of wear, three-dimensional linear rate of wear, volumetric wear rate and total linear wear were all significantly reduced for cross-linked polyethylene. The risk ratio for radiological osteolysis was 0.40 (95% confidence interval 0.27 to 0.58; I(2) = 0%), favouring cross-linked polyethylene. The follow-up was not long enough to show a difference in the need for revision surgery.


Subject(s)
Arthroplasty, Replacement, Hip/instrumentation , Hip Prosthesis , Polyethylene/chemistry , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Prosthesis Design , Prosthesis Failure , Randomized Controlled Trials as Topic , Research Design , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...