1.
Med Phys ; 36(5): 1512-20, 2009 May.
Article in English | MEDLINE | ID: mdl-19544767

ABSTRACT

An easily applicable empirical formula was derived for use in the assessment of the photoneutron dose at the maze entrance of a 15 MV medical accelerator treatment room. The neutron dose equivalent rates around the Varian medical accelerator head calculated with the Monte Carlo code MCNPX were used as the source term in producing the base data. The dose equivalents were validated by measurements with bubble detectors. Irradiation geometry conditions expected to yield higher neutron dose rates in the maze were selected: a 20 x 20 cm2 irradiation field, gantry rotation plane parallel to the maze walls, and the photon beams directed to the opposite wall to the maze entrance. The neutron dose equivalents at the maze entrance were computed for 697 arbitrary single-bend maze configurations by extending the Monte Carlo calculations down to the maze entrance. Then, the empirical formula was derived by a multiple regression fit to the neutron dose equivalents at the maze entrance for all the different maze configurations. The goodness of the empirical formula was evaluated by applying it to seven operating medical accelerators of different makes. When the source terms were fixed, the neutron doses estimated from the authors' formula agreed better with the corresponding MCNPX simulations than the results of the Kersey method. In addition, compared with the Wu-McGinley formula, the authors' formula provided better estimates for the mazes with length longer than 8.5 m. There are, however, discrepancies between the measured dose rates and the estimated values from the authors' formula, particularly for the machines other than a Varian model. Further efforts are needed to characterize the neutron field at the maze entrance to reduce the discrepancies. Furthermore, neutron source terms for the machines other than a Varian model should be simulated or measured and incorporated into the formula for accurate extended application to a variety of models.


Subject(s)
Algorithms , Models, Theoretical , Particle Accelerators/instrumentation , Radiation Monitoring/methods , Radiation Protection/methods , Computer Simulation , Neutrons , Radiation Dosage
2.
Radiat Prot Dosimetry ; 115(1-4): 271-5, 2005.
Article in English | MEDLINE | ID: mdl-16381727

ABSTRACT

The design of radiation shielding was evaluated for a proton therapy facility being established at the National Cancer Center in Korea. The proton beam energy from a 230 MeV cyclotron is varied for therapy using a graphite target. This energy variation process produces high radiation and thus thick shielding walls surround the region. The evaluation was first carried out using analytical expressions at selected locations. Further detailed evaluations have been performed using the Monte Carlo method. Dose equivalent values were calculated to be compared with analytical results. The analytical method generally yielded more conservative values. With consideration of adequate occupancy factors annual dose equivalent rates are kept <1 mSv y(-1) in all areas. Construction of the building is expected to be completed near the end of 2004 and the installation of therapy equipment will begin a few months later.


Subject(s)
Facility Design and Construction/methods , Proton Therapy , Radiation Monitoring/methods , Radiation Protection/instrumentation , Radiation Protection/methods , Radiotherapy/instrumentation , Computer Simulation , Equipment Design/methods , Equipment Failure Analysis/methods , Facility Design and Construction/instrumentation , Korea , Models, Statistical , Monte Carlo Method , Oncology Service, Hospital , Particle Accelerators/instrumentation , Radiation Dosage , Risk Assessment/methods , Risk Factors