Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Nanomicro Lett ; 15(1): 76, 2023 Mar 28.
Article in English | MEDLINE | ID: mdl-36976370

ABSTRACT

Although there is a high demand for absorption-dominant electromagnetic interference (EMI) shielding materials for 5G millimeter-wave (mmWave) frequencies, most current shielding materials are based on reflection-dominant conductive materials. While there are few absorption-dominant shielding materials proposed with magnetic materials, their working frequencies are usually limited to under 30 GHz. In this study, a novel multi-band absorption-dominant EMI shielding film with M-type strontium ferrites and a conductive grid is proposed. This film shows ultralow EMI reflection of less than 5% in multiple mmWave frequency bands with sub-millimeter thicknesses, while shielding more than 99.9% of EMI. The ultralow reflection frequency bands are controllable by tuning the ferromagnetic resonance frequency of M-type strontium ferrites and composite layer geometries. Two examples of shielding films with ultralow reflection frequencies, one for 39 and 52 GHz 5G telecommunication bands and the other for 60 and 77 GHz autonomous radar bands, are presented. The remarkably low reflectance and thinness of the proposed films provide an important advancement toward the commercialization of EMI shielding materials for 5G mmWave applications.

2.
ACS Appl Mater Interfaces ; 14(34): 39255-39264, 2022 Aug 31.
Article in English | MEDLINE | ID: mdl-35975758

ABSTRACT

Electromagnetic wave (EMW)-absorbing materials, manufactured with composites of magnetic particles, are essential for maintaining a high complex permeability and modulated permittivity for impedance matching. However, commonly available EMW-absorbing materials are unsatisfactory owing to their low complex permeability in the high-frequency band. Herein, we report a thin, flexible EMW-absorbing membrane comprising shape-modulated FeCo nanobelts/boron nitride nanoparticles, which enables enhanced complex permeability in the S, C, and X bands (2-12 GHz). The boron nitride nanoparticles that are introduced to the FeCo nanobelts demonstrate control of the complex permittivity, leading to an effective impedance matching close to 1, consequently resulting in a high reflection loss value of -42.2 dB at 12.0 GHz with only 1.6 mm thickness. In addition, the incorporation of boron nitride nanoparticles improves the thermal conductivity for the heat dissipation of the absorbed electromagnetic wave energy. Overall, the comprehensive study of nanomaterial preparation and shape modulation technologies can lead to the fabrication of an excellent EMW-absorbing flexible composite membrane.

3.
Nanoscale ; 13(27): 12004-12016, 2021 Jul 15.
Article in English | MEDLINE | ID: mdl-34212957

ABSTRACT

Herein, we introduce novel 1-dimensional nano-chained FeCo particles with unusually-high permeability prepared by a highly-productive thermal plasma synthesis and demonstrate an electromagnetic wave absorber with exceptionally low reflection loss in the high-frequency regime (1-26 GHz). During the thermal plasma synthesis, spherical FeCo nanoparticles are first formed through the nucleation and growth processes; then, the high temperature zone of the thermal plasma accelerates the diffusion of constituent elements, leading to surface-consolidation between the particles at the moment of collision, and 1-dimensional nano-chained particles are successfully fabricated without the need for templates or a complex directional growth process. Systematic control over the composition and magnetic properties of FexCo1-x nano-chained particles also has been accomplished by changing the mixing ratio of the Fe-to-Co precursors, i.e. from 7 : 3 to 3 : 7, leading to a remarkably high saturation magnetization of 151-227 emu g-1. In addition, a precisely-controlled and uniform surface SiO2 coating on the FeCo nano-chained particles was found to effectively modulate complex permittivity. Consequently, a composite electromagnetic wave absorber comprising Fe0.6Co0.4 nano-chained particles with 2.00 nm-thick SiO2 surface insulation exhibits dramatically intensified permeability, thereby improving electromagnetic absorption performance with the lowest reflection loss of -43.49 dB and -10 dB (90% absorbance) bandwidth of 9.28 GHz, with a minimum thickness of 0.85 mm.

4.
ACS Appl Mater Interfaces ; 12(45): 50803-50811, 2020 Nov 11.
Article in English | MEDLINE | ID: mdl-33135419

ABSTRACT

Fiber strain sensors that are directly woven into smart textiles play an important role in wearable systems. These sensors require a high sensitivity to detect the subtle strain in practical applications. However, traditional fiber strain sensors with constant diameters undergo homogeneous strain distribution in the axial direction, thereby limiting the sensitivity improvement. Herein, a novel strategy of internal or external structural design is proposed to significantly improve the sensitivity of fiber strain sensors. The fibers are produced with directional increases in diameter (internal design) or polydimethylsiloxane (PDMS) microbeads attached to surfaces (external design) by combining hollow glass tubes used as templates with PDMS drops. The structural modification of the fiber significantly impacts the sensing performance. After optimizing structural parameters, the highest gauge factor reaches 123.1 in the internal-external structure design at 25% strain. A comprehensive analysis reveals that the desirable scheme is the internal structural design, which features a high sensitivity of 110 with a 100% improvement at ∼5-20% strain. Because of the sufficiently robust interface, even at the 800th cycle, fiber sensors still possessed an excellent stable performance. The morphology evolution mechanism indicates that the resistance increase is closely related with the increased peak width and distance, and the appearance of gaps. Based on the finite element modeling simulation, the quantified effective contributions of different strategies positively correlate with the improved sensitivity. The proposed fiber strain sensors, which are woven into the two-dimensional network structure, exhibit an excellent capability for displacement monitoring and facilitate the traffic control of crossroads.

5.
ACS Appl Mater Interfaces ; 10(41): 35108-35117, 2018 Oct 17.
Article in English | MEDLINE | ID: mdl-30230315

ABSTRACT

Solid polymer electrolytes (SPEs) have drawn attention for promising multifunctional electrolytes requiring very good mechanical properties and ionic conductivity. To develop a safe SPE for energy storage applications, mechanically robust cross-linked epoxy matrix is combined with fast ion-diffusing ionic liquid/lithium salt electrolyte (ILE) via a simple one-pot curing process. The epoxy-rich SPEs show higher Young's modulus ( E), with higher glass transition temperature ( Tg) but lower ionic conductivity (σdc) with a higher activation energy, compared to the ILE-rich SPEs. The incorporation of inorganic robust Al2O3 nanowire simultaneously provides excellent mechanical robustness ( E ≈ 1 GPa at 25 °C) and good conductivity (σdc ≈ 2.9 × 10-4 S/cm at 25 °C) to the SPE. This suggests that the SPE has a bicontinuous microphase separation into ILE-rich and epoxy-rich microdomain, where ILE continuous conducting phases are intertwined with a sturdy cross-linked amorphous epoxy framework, supported by the observation of the two Tgs and low tortuosity as well as the microstructural investigation. After assembling the SPE with activated carbon electrodes, we successfully demonstrate the supercapacitor performance, exhibiting high energy and power density (75 W h/kg at 382 W/kg and 9.3 kW/kg at 44 W h/kg). This facile strategy holds tremendous potential to advance multifunctional energy storage technology for next-generation electric vehicles.

6.
ACS Appl Mater Interfaces ; 10(38): 32323-32330, 2018 Sep 26.
Article in English | MEDLINE | ID: mdl-30168328

ABSTRACT

We report the effect of epoxy adhesion layers with different mechanical or physical property on a magnetoelectric (ME) composite laminate composed of FeBSi alloy (Metglas)/single-crystal Pb(Mg1/3Nb2/3)O3-Pb(Zr,Ti)O3/Metglas to achieve an improved ME conversion performance. Through theoretical simulation, it was revealed that the Young's modulus and the thickness of interfacial adhesives were major parameters that influence the conversion efficiency in ME composites. In the experimental evaluation, we utilized three epoxy materials with a distinct Young's modulus and adjusted the average thickness of the adhesion layers to optimize the ME conversion. The experimental results show that a thin epoxy layer with a high Young's modulus provided the best performance in the inorganic-based ME conversion process. By tailoring the interfacial adhesion property, the ME laminate generated a high conversion coefficient of 328.8 V/(cm Oe), with a mechanical quality factor of 132.0 at the resonance mode. Moreover, we demonstrated a highly sensitive alternating current magnetic field sensor that had a detection resolution below 10 pT. The optimization of the epoxy layers in the ME laminate composite provided significant enhancement of the ME response in a simple manner.

7.
J Dent Anesth Pain Med ; 16(4): 303-307, 2016 Dec.
Article in English | MEDLINE | ID: mdl-28879319

ABSTRACT

BACKGROUND: In dental intravenous sedation, continuous intravenous infusion of a low-dose drug requires an infusion pump such as a syringe pump. To develop a new syringe pump for clinical use, the functions of the pump must meet certain international standards. Various safety and efficacy tests must be performed on the syringe pump, as stipulated by these standards, and an approval must be received from the approving agency based on such test results. METHODS: The authors of the present study developed a novel syringe pump and performed efficacy evaluation by testing its infusion speed at 1 and 25 ml/h, and infusion performance testing at 2 and 24 h. Moreover, performance evaluation was conducted by comparing the novel pump to an existing pump with the infusion speed varied from 1 to 5 ml/h. RESULTS: In the efficacy testing on the newly developed syringe pump, infusion with the infusion speed initially set to 1 ml/h resulted in infusion speeds of 1.00 and 0.99 ml/h in the 2- and 24-h assessment, respectively. Changing the infusion speed setting to 25 ml/h resulted in an infusion speed of 25.09 and 23.92 ml/h in the 2- and 24-h assessment, respectively. These results show no significant differences when compared with other commercially available pumps. CONCLUSIONS: The efficacy testing of the newly developed syringe pump showed the accuracy to be within tolerance. Based on these findings, we believe that the newly developed syringe pump is suitable for clinical use.

8.
J Dent Anesth Pain Med ; 15(1): 5-10, 2015 Mar.
Article in English | MEDLINE | ID: mdl-28879252

ABSTRACT

BACKGROUND: Patients were subjected to post-discharge follow-up (by telephone) in order to investigate the potential complications of outpatient general anesthesia or deep sedation that could develop in disabled dental patients discharged from the hospital. The ultimate aim of this study was to establish an appropriate response measure for such complications. METHODS: The caregivers of 79 disabled patients who underwent dental procedures under general anesthesia at our outpatient clinic were interviewed over telephone. Necessary care instructions were provided during the phone calls when required. The patient satisfaction level regarding the telephonic follow-up care was surveyed by additional telephone calls. RESULTS: Most of the patients did not suffer any serious complications; however, some reported fever and bleeding. The data obtained in this study can be utilized towards the development of caregiver education pertaining to the ambulatory general anesthesia of dental patients with disabilities. CONCLUSIONS: Additionally, we hope that the findings of this study will help minimize the effects of complications experienced by disabled dental patients undergoing ambulatory general anesthesia, as well as increase the overall patient satisfaction level.

SELECTION OF CITATIONS
SEARCH DETAIL
...