Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Orthop Traumatol Surg Res ; 103(1): 21-25, 2017 02.
Article in English | MEDLINE | ID: mdl-27890581

ABSTRACT

BACKGROUND: Rates of dislocation following primary total hip arthroplasty (THA) vary from 0.5 to 10%. Dual-mobility cups in THA demonstrate increased stability. Clinical outcomes following THA with dual-mobility cups have been reported, but gait has not been assessed. Therefore we performed a retrospective case control study to answer: (1) is gait better in patients following THA with a dual-mobility cup than in frail, elderly patients of the same age? (2) Are clinical outcomes better in patients following THA with a dual-mobility cup than in frail, elderly patients? (3) What is the dislocation rate following THA with a dual-mobility cup? HYPOTHESIS: We hypothesized that patients who underwent THA with a dual-mobility cup have a better gait compared to frail, elderly patients of the same age. PATIENTS AND METHODS: Twenty patients (22 hips), mean age 79.9±7.7 (range, 62.3-88.3) years were assessed in this retrospective case-control series 5.6±1.4 (range: 4.1-8.8) years following dual-mobility cup THA. A reference group consisted of 72 "frail elderly" patients in a rehabilitation hospital for health problems unrelated to the lower limb, with no lower limb surgery or neurological conditions. Temporal and spatial gait performance were measured with four miniature gyroscopes, mounted on each thigh and calf, while patients walked freely along a 30m corridor. Harris Hip Score, WOMAC, radiological outcomes, and dislocation rate were determined. RESULTS: All gait parameters were better in the dual-mobility group compared to the frail elderly group. The dual-mobility group had a higher cadence (100.3 steps/minute versus 75.6 steps/minute), shorter (relative to gait cycle time) stance (61.6% versus 67.8%), shorter (relative to gait cycle time) double stance (23.3% versus 36.0%), longer stride (1.13m versus 0.80m), and faster walking speed (0.96m/s versus 0.52m/s). Range of motion of the shank, thigh and knee were better in the dual-mobility group. Harris Hip Score was 87.6±13.9 (range 51-100) and WOMAC score was 11.3±12.1 (range 0-34) in the THA group. We observed no dislocations. DISCUSSION: Gait patterns five years following THA with the dual-mobility cup were better or comparable to published study populations. LEVEL OF EVIDENCE: III, retrospective case-control series.


Subject(s)
Arthroplasty, Replacement, Hip/instrumentation , Gait , Hip Dislocation/etiology , Hip Joint/physiopathology , Hip Prosthesis , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip/adverse effects , Case-Control Studies , Female , Follow-Up Studies , Frail Elderly , Hip Prosthesis/adverse effects , Humans , Joint Instability/etiology , Knee Joint/physiopathology , Male , Middle Aged , Radiography , Range of Motion, Articular , Retrospective Studies , Treatment Outcome , Walking
2.
Physiol Meas ; 36(3): 547-60, 2015 Mar.
Article in English | MEDLINE | ID: mdl-25690269

ABSTRACT

Kinematic functional evaluation with body-worn sensors provides discriminative and responsive scores after shoulder surgery, but the optimal movements' combination has not yet been scientifically investigated. The aim of this study was the development of a simplified shoulder function kinematic score including only essential movements. The P Score, a seven-movement kinematic score developed on 31 healthy participants and 35 patients before surgery and at 3, 6 and 12 months after shoulder surgery, served as a reference. Principal component analysis and multiple regression were used to create simplified scoring models. The candidate models were compared to the reference score. ROC curve for shoulder pathology detection and correlations with clinical questionnaires were calculated. The B-B Score (hand to the Back and hand upwards as to change a Bulb) showed no difference to the P Score in time*score interaction (P > .05) and its relation with the reference score was highly linear (R(2) > .97). Absolute value of correlations with clinical questionnaires ranged from 0.51 to 0.77. Sensitivity was 97% and specificity 94%. The B-B and reference scores are equivalent for the measurement of group responses. The validated simplified scoring model presents practical advantages that facilitate the objective evaluation of shoulder function in clinical practice.


Subject(s)
Movement/physiology , Physical Examination/methods , Severity of Illness Index , Shoulder/physiology , Shoulder/physiopathology , Adult , Biomechanical Phenomena , Female , Humans , Humerus/physiology , Humerus/physiopathology , Male , Middle Aged , Principal Component Analysis , Regression Analysis , Shoulder/surgery , Surveys and Questionnaires , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...