Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 29
Filter
Add more filters










Publication year range
1.
Appl Radiat Isot ; 204: 111109, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38029636

ABSTRACT

The goal of this study is to provide a benchmark for the use of Monte Carlo simulation when applied to coincidence summing corrections. The examples are based on simple geometries: two types of germanium detectors and four kinds of sources, to mimic eight typical measurement conditions. The coincidence corrective factors are computed for four radionuclides. The exercise input files and calculation results with practical recommendations are made available for new users on a dedicated webpage.

2.
Appl Radiat Isot ; 167: 109298, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33010791

ABSTRACT

Palladium-103 decays through electron capture to excited levels of 103Rh, and especially to the 39.748-keV metastable state. A high activity palladium chloride solution was standardized by liquid scintillation, using the Triple-to-Double Coincidence Ratio method. The absolute photon emission intensities were determined by gamma-ray spectrometry using point sources prepared with the standard solution. Different detectors and measuring conditions were used to cross-reference the results. The most intense photon emission intensities are derived with about 1% relative combined standard uncertainty.

3.
Appl Radiat Isot ; 166: 109349, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32818806

ABSTRACT

The 2011 Decay Data Evaluation Project (DDEP) evaluation for 147Nd includes recommended absolute emission intensities for the two main gamma-rays at 91.105 (2) keV and 531.016 (22) keV of 0.284 (18) and 0.127 (9) respectively, i.e. with uncertainties of 6.3% and 7.1%. These large uncertainties stem from inconsistencies in the published data and are unfit for modern purposes, since the production of 147Nd is used as an important neutron flux dosimeter. The LNE-LNHB has undertaken new absolute gamma-ray emission intensity measurements. The results of these measurements will be presented, along with a full uncertainty budget, and their effect on the recommended data uncertainties will be discussed.

4.
Appl Radiat Isot ; 155: 108921, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31629294

ABSTRACT

An internal consistency test of the calculation of coincidence-summing correction factors FC for volume sources is presented. The test is based on exact equations relating the values of FC calculated for three ideal measurement configurations. The test is applied to a number of 33 sets of FC values sent by 21 teams. Most sets passed the test, but not the results obtained using the quasi-point source approximation; in the latter case the test qualitatively indicated the magnitude of the bias of FC.

5.
Appl Radiat Isot ; 154: 108850, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31476556

ABSTRACT

Monte Carlo (MC) simulation is widely used in gamma-ray spectrometry, however, its implementation is not always easy and can provide erroneous results. The present action provides a benchmark for several MC software for selected cases. The examples are based on simple geometries, two types of germanium detectors and four kinds of sources, to mimic eight typical measurement conditions. The action outputs (input files and efficiency calculation results, including practical recommendations for new users) are made available on a dedicated webpage.

6.
Appl Radiat Isot ; 153: 108826, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31525708

ABSTRACT

Holmium-166 is a high-energy ß--emitter radionuclide (~ 1.8 MeV) with a short half-life (~26.8h) that offers great potential as an alternative to 90Y for the treatment of liver cancer based on radioembolization. The possibility of quantitative Single Photon Emission Computed Tomography (SPECT) imaging of the main γ-ray emission at 80.6 keV, in addition to strong paramagnetic properties suitable for Magnetic Resonance Imaging (MRI), complement this therapeutic potential. The present paper describes the measurements carried out in three European radionuclide metrology laboratories for primary standardization of 166Ho and new determinations of X- and γ-ray photon-emission intensities in the framework of the European EMPIR project MRTDosimetry. New half-life measurements were also performed.


Subject(s)
Holmium/analysis , Radiation Dosage , Radioisotopes/analysis , Humans , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/radiotherapy , Tomography, Emission-Computed, Single-Photon
7.
Appl Radiat Isot ; 134: 182-189, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29066050

ABSTRACT

Today, there is growing interest for neutrons in the intermediate energy range between 100keV and 1MeV, which are responsible for damaging materials in reactor. To improve this deficiency, we use rhodium and niobium which, through the inelastic neutron scattering reaction, leads to the formation of 103mRh and 93mNb low-energy X-emitters. This paper describes the improvements and validation made on this type of complex measurement by X spectrometry: self-attenuation, fluorescence correction, and emission intensity were poorly known previously.

8.
Appl Radiat Isot ; 134: 399-405, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29031491

ABSTRACT

A new experiment was designed to measure the photon emission intensities in the decay of 103mRh. The rhodium samples were activated in the ISIS experimental nuclear reactor at CEA Saclay. The procedure includes an absolute activity measurement by liquid scintillation counting using the Triple-to-Double Coincidence Ratio method, followed by X-ray spectrometry using a high-purity germanium detector to determine the photon emission intensities. The new result (IX = 0.0825 (17)) is derived with a significant reduction of the uncertainty.

9.
Appl Radiat Isot ; 134: 131-136, 2018 Apr.
Article in English | MEDLINE | ID: mdl-28697980

ABSTRACT

The efficiency calibration for different high-purity germanium detectors in the low-energy range was established by the conventional method, using standard radioactive sources. The peak shapes were carefully analysed taking account of natural linewidth, full-energy width at half maximum and scattering. Complementary information was obtained by Monte Carlo simulation using the PENELOPE code, after optimization of the geometrical parameters. This was used to measure photon emission intensities of some low-energy emitting radionuclides, including 133Ba, and compared to the tabulated values.

10.
Appl Radiat Isot ; 109: 482-486, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26651169

ABSTRACT

The aim of this study was to check for equivalence of computer codes that are capable of performing calculations of true coincidence summing (TCS) correction factors. All calculations were performed for a set of well-defined detector parameters, sample parameters and decay scheme data. The studied geometry was a point source of (133)Ba positioned directly on the detector window of a low-energy (n-type) detector. Good agreement was established between the TCS correction factors computed by the different codes.

11.
Appl Radiat Isot ; 87: 336-41, 2014 May.
Article in English | MEDLINE | ID: mdl-24332343

ABSTRACT

The aim of the study was to check for equivalence of computer codes that can perform calculations of true coincidence summing correction factors. All calculations were performed for a set of well-defined detector and sample parameters, without any reference to empirical data. For a p-type detector model the application of different codes resulted in satisfactory agreement in the calculated correction factors. For high-efficiency geometries in combination with an n-type detector and a radionuclide emitting abundant X-rays the results were scattered.

12.
Appl Radiat Isot ; 87: 101-6, 2014 May.
Article in English | MEDLINE | ID: mdl-24369893

ABSTRACT

This study focuses on two radioisotopes of silver, (108m)Ag and (110m)Ag, characterized by a complex decay scheme. Each isotope has two disintegration modes, the isomeric transition leading to the daughter isotope ((108)Ag and (110)Ag, respectively) with a short half-life. The radioactive solution was obtained by neutron activation on silver powder enriched in (109)Ag. Gamma-spectrometry was carried out using a calibrated high purity germanium detector. The main relative photon emission intensities for both radionuclides were obtained and compared with previously published values.

13.
Appl Radiat Isot ; 87: 342-7, 2014 May.
Article in English | MEDLINE | ID: mdl-24360861

ABSTRACT

Xenon-127 was standardized by internal gas counting using three proportional counters in a differential arrangement to eliminate edge effects. The detection efficiency of the proportional counters was calculated by considering the cascade of events following the electron capture and associated gamma transitions. Activity per unit volume was measured with 0.7% relative standard uncertainty. Gamma-ray spectrometry was performed and absolute photon emission intensities were derived. This study shows that (127)Xe could be a surrogate for (133)Xe for the calibration of remote radio-xenon monitoring stations.

14.
Appl Radiat Isot ; 70(9): 2112-8, 2012 Sep.
Article in English | MEDLINE | ID: mdl-22445105

ABSTRACT

The second part of an intercomparison of the coincidence summing correction methods is presented. This exercise concerned three volume sources, filled with liquid radioactive solution. The same experimental spectra, decay scheme and photon emission intensities were used by all the participants. The results were expressed as coincidence summing corrective factors for several energies of (152)Eu and (134)Cs, and different source-to-detector distances. They are presented and discussed.


Subject(s)
Algorithms , Artifacts , Radioisotopes/analysis , Radioisotopes/standards , Radiometry/methods , Radiometry/standards , Spectrometry, Gamma/methods , Half-Life , Internationality , Radiation Dosage , Radioisotopes/chemistry , Reference Standards , Reference Values
15.
Appl Radiat Isot ; 70(9): 1894-9, 2012 Sep.
Article in English | MEDLINE | ID: mdl-22406222

ABSTRACT

The purposes of this study were to create national activity standards of (64)Cu, to make possible the definition of an international key comparison reference value and to determine the decay data in order to improve the decay scheme. Four laboratories measured the activity of a (64)Cu solution; these results were compared through the International Reference System. Moreover, the laboratories carried out new measurements of the photon emission intensities and of the half-life. A new decay scheme was derived from these new values and the previously published ones.


Subject(s)
Copper Radioisotopes/analysis , Copper Radioisotopes/chemistry , Radiometry/standards , Half-Life , Internationality , Radiation Dosage , Reference Standards , Reference Values
16.
J Environ Radioact ; 101(9): 780-3, 2010 Sep.
Article in English | MEDLINE | ID: mdl-20537447

ABSTRACT

In this work, the activities of radionuclides in a marine sediment sample have been determined. The gamma spectrometer comprises an N type coaxial HPGe detector with active shielding to reduce cosmic background. The mass activities of radionuclides have been derived and found to be around a few Bq kg(-1) to several hundreds Bq kg(-1) with relative uncertainties in this paper quoted corresponding to the combined standard uncertainties (k=1).


Subject(s)
Geologic Sediments/chemistry , Radiation Monitoring , Radioisotopes/analysis , Spectrometry, Gamma/methods , Water Pollutants, Radioactive/analysis , Radioisotopes/chemistry , Seawater/chemistry , Water Pollutants, Radioactive/chemistry
17.
Appl Radiat Isot ; 68(7-8): 1571-7; discussion 1577, 2010.
Article in English | MEDLINE | ID: mdl-20116267

ABSTRACT

To study the decay scheme of (126)Sn, two samples of a purified solution were measured by gamma-ray spectrometry and the relative photon emission intensities were determined. The (126)Sb(m) isomeric branching ratio was derived to be 18.6 (6) %. The maximum beta energy of the (126)Sn decay was checked by liquid scintillation. The Kbeta/Kalpha intensity ratio of Sb was determined being 0.226 (11). These new experimental results were used to re-examine the whole decay scheme of (126)Sn and its daughters.

18.
Appl Radiat Isot ; 68(7-8): 1207-10, 2010.
Article in English | MEDLINE | ID: mdl-20153206

ABSTRACT

An international exercise, registered as EUROMET project no. 907, was launched to measure both the activity of a solution of (124)Sb and the photon emission intensities of its decay. The same solution was sent by LNE-LNHB to eight participating laboratories. In order to identify possible biases, the participants were asked to use all possible activity measurement methods available in their laboratory and then to determine their reference value for comparison. Thus, measurement results from 4pibeta-gamma coincidence/anti-coincidence counting, CIEMAT/NIST liquid-scintillation counting, 4pigamma counting with well-type ionization chambers and well-type crystal detectors were given. The results are compared and show a maximum discrepancy of about 1.6%: possible explanations are proposed.


Subject(s)
Antimony/analysis , Antimony/standards , International Cooperation , Photons , Reference Values , Reproducibility of Results , Scintillation Counting , Solutions , Weights and Measures
19.
Appl Radiat Isot ; 68(7-8): 1407-12; discussion 1412, 2010.
Article in English | MEDLINE | ID: mdl-20117939

ABSTRACT

A comparison of the coincidence summing correction methods is presented. Since there are several ways for computing these corrections, each method has advantages and drawbacks that could be compared. This part of the comparison was restricted to point sources. The same experimental spectra, decay scheme and photon emission intensities were used by all the participants. The results were expressed as coincidence summing correction factors for several energies of (152)Eu and (134)Cs, and three source-to-detector distances. They are presented and discussed.

20.
Appl Radiat Isot ; 68(10): 2026-30, 2010 Oct.
Article in English | MEDLINE | ID: mdl-20171111

ABSTRACT

An international exercise, registered as EUROMET project no. 907, was launched to measure both the activity of a solution of (124)Sb and the photon emission intensities of its decay. The same solution was sent by LNE-LNHB to eight participating laboratories, six of which sent results for photon emission intensities both in absolute and in relative terms. From these results and including previous published values, a consistent decay scheme was worked out, proving that problems in activity measurements have not been due to decay scheme data.

SELECTION OF CITATIONS
SEARCH DETAIL
...