Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Language
Publication year range
1.
Acta Gastroenterol Latinoam ; 27(1): 7-14, 1997.
Article in Spanish | MEDLINE | ID: mdl-9412128

ABSTRACT

UNLABELLED: The aim was to study the alterations in mechanosensitivity, gastric emptying, and electrogastrography (E.G.G.) in a population of patients suffering from N.O.D. eighteen controls (9 males, 9 females, mean age 49.33 years old < SEM 3.62, range 24-74) and 32 patients with N.O.D. (22 males, 21 females, mean age 55.72 years old, SEM 2.87, range 17-86) were studied. Gastric mechano-sensitivity with a latex balloon of low compliance inflated "in phasic" was investigated, and intra balloon pressure was recorded. Gastric emptying with a mixed meal marked with 99 Tc in the solid phase, containing 250 Cal, was studied. E.G.G. was studied using two skin surface electrodes Ag-2C1Ag placed on epigastric area following a probalistic antral axe. Only dominant frequency in each block was considered, and % of total abnormalities on total recording time lesser than 2 c.p.m or more than 4 c.p.m. was considered. Recordings were taken during fast time during 30 minutes, and 30 minutes after a meal containing 250 Cal. Analysis with F.F.T, and spectral running. RESULTS: In 67.92% a delay in gastric emptying was observed. 56.3% did not complete 700 ml. of balloon inflation because of pain, Vs 16.8% in controls (p < 0.001) The slopes of intra-balloon pressure were not different in both groups. (Variance, F-NS). Mean E.C.A was 2.99 c.p.m in control, Vs 3.46 in fasting and 3.64 in postprandial period in N.O.D. (p = NS) Differences in fasting and postprandial % of arrhythmias total time recording were significant in N.O.D. ("t". 0.02 > p 0.01). Twenty percent of controls showed isolated tachygastria, but dominant frequencies never were higher than 6 c.p.m and never last more than 8% of the total recording time. Sixty eight point seventy five percent of N.O.D. showed arrhythmias. 48% of tachygastrias were in the range 30-60% of total recording time. No differences in gastric emptying between patient presenting pain with = < 700 ml. and < 700 ml. of balloon inflation were seen. Patients with sensorial threshold = < 700 ml. showed less frequent tachygastria (0.01 < p < 0.01). Patients with delayed gastric emptying showed more frequent tachygastria (94.7%, 0.05 < p < 0.02) CONCLUSIONS: a) E.G.G. abnormalities would more frequent in "motor" subpopulation; b) No association between abnormalities in gastric emptying, abnormal thresholds in mechanosensitivity and/or E.G.G. and any clinical subtype of Dyspepsia can be showed; h) although gastric arrhythmia was more frequent in motor than in sensorial abnormalities, it may represents a more generalized disturbance in central modulation in afferents and efferents inputs and outputs.


Subject(s)
Dyspepsia/physiopathology , Gastric Emptying/physiology , Gastrointestinal Motility/physiology , Stomach/physiopathology , Adolescent , Adult , Aged , Aged, 80 and over , Electromyography/methods , Female , Humans , Male , Middle Aged , Prospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...