Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Metas enferm ; 16(5): 12-17, jun. 2013. ilus, graf
Article in Spanish | IBECS | ID: ibc-113754

ABSTRACT

Objetivos: evaluar la eficacia de un sistema de monitorización (la calidad y amplitud del registro, señal transmitida en la tarjeta, parámetros de medición), el grado de satisfacción de los usuarios y la futura implementación del dispositivo en pacientes de bajo riesgo para poder llegar a un mayor número de enfermos en un programa de rehabilitación cardíaca (RC) domiciliario. Material y método: estudio descriptivo transversal sobre pacientes en el programa de RC. La recogida de datos se realizó a través de un registro. Se aplicó un análisis descriptivo de todas las variables del estudio, y para evaluar la eficacia del dispositivo se efectuó la prueba ANOVA de un factor, utilizando el programa SPSS 18.0.Resultados: participaron 60 pacientes (86,3% eran varones, con una edad media de 54,9 años). La calidad del registro fue buena en un40% de los casos y la amplitud en un 52%. Los registros presentaron escasos artefactos (28%) y solo el 24% había tenido alguna desconexión en el dispositivo. Se ha comprobado la fiabilidad del dispositivo con el empleo del pulsímetro como muy buena (76%). El uso de la camiseta le ha resultado muy cómoda a un 56%, y ha ayudado a realizar mejor la actividad física al 64%. El 92% recomendaría el uso de la camiseta a otras personas. Conclusiones: la plataforma de monitorización cardiaca de Nuuboha desarrollado una solución que permite biomonitorizar de forma remota y no invasiva con un registro de calidad en el tratamiento domiciliario de los pacientes, además se han definido las mejoras a implantaren el futuro sistema remoto (AU)


Objectives: to assess the efficacy of a monitoring system (quality and range of recording, signal transmitted in the card, measurement parameters),the extent of satisfaction by users, and the future implementation of the device in low-risk patients in order to reach a higher number of patients in a Home-based Cardiac Rehabilitation (CR)Program. Materials and method: transversal descriptive study on patients in the CR Program. Data collection was conducted through a registry. A descriptive analysis for all the study variables was implemented, and in order to assess the device efficacy, the ANOVA test for a single factor was conducted, using the SPSS 18.0 program. Results: sixty (60) patients were included in the study (86.3% were male, with a median age of 54.9 years). The registry quality was good in 40% of cases, and the range was good in 52% of cases. Registries presented few artifacts (28%), and only 24% showed some disconnection in the device. The device reliability has been confirmed as very good (76%) by using the pulsimeter. Wearing the t-shirt has been very comfortable for 56% of patients, and it has helped to a better practice of physical activities to 64% of patients. 92% of the subjects would recommend the use of the t-shirt to other people. Conclusions: the Cardiac Monitoring Platform by Nuubo has developed a solution which allows remote and non-invasive bio-monitoring, with a good quality registry for patient treatment at home; besides, the improvements to be implemented in the future remote system have been defined (AU)


Subject(s)
Humans , Remote Consultation/methods , Monitoring, Ambulatory/methods , Heart Diseases/rehabilitation , Pilot Projects , Quality of Health Care
SELECTION OF CITATIONS
SEARCH DETAIL
...