Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 316
Filter
1.
Dent Mater J ; 2024 Jul 04.
Article in English | MEDLINE | ID: mdl-38960667

ABSTRACT

The purpose of this study was to evaluate the effect of the atmospheric pressure plasma treatment as a surface treatment method on the contact angle and shear bond strength (SBS) of zirconia ceramics and the failure mode between the self-adhesive resin luting agent and zirconia. The zirconia specimens were divided into eight groups based on the surface treatment method: alumina blasting, air plasma, argon plasma (AP), Katana cleaner, ozonated water, ozonated water+AP, Katana cleaner+AP, and tap water+AP. The contact angles, SBS, and fracture modes were tested. AP treatment significantly reduced the contact angle (p<0.0001). The combination of AP and other cleaning methods showed a higher bond strength and more mixed fractures. Our findings indicate that using atmospheric pressure plasma with argon gas, combined with other cleaning methods, results in a stronger bond than when using alumina blasting alone.

2.
Biomater Investig Dent ; 11: 40591, 2024.
Article in English | MEDLINE | ID: mdl-38873366

ABSTRACT

Objectives: The aim of this article was to compare the colour stability of short fibre-reinforced computer-assisted design/computer-assisted manufacturing (CAD/CAM) composite (SFRC CAD) to commercially available CAD/CAM materials following prolonged immersion in a variety of beverages. Furthermore, the influence of the polishing technique was evaluated. Materials and methods: A total of 120 rectangular specimens (10 mm length × 14 mm width × 2 mm thickness) were prepared from SFRC CAD, IPS e-max, Cerasmart 270, Celtra Duo, Enamic, and Brilliant Crios. The specimens underwent polishing through either a laboratory polishing machine equipped with 4000-grit silicon carbide paper or chairside polishing using Sof-Lex spiral. Twenty specimens of each tested CAD/CAM material were randomly divided into four groups (n = 5) based on the staining solution used in order to evaluate the colour stability of the materials. Group 1: distilled water, Group 2: coffee, Group 3: red wine, Group 4: coke. Using a spectrophotometer, the colour changes (∆E) of all CAD/CAM materials were assessed at baseline, and after 1 and 12 weeks of staining. Three-way analysis of variance was used to analyse the data (α = 0.05). Results: The staining solution and material type showed a significant influence on the CAD/CAM specimens' colour stability (p < 0.05), while polishing method had no significant influence (p > 0.05). The average ∆E values for specimens submerged in wine were considerably higher (p < 0.05) than those for the other solutions. SFRC CAD, Cerasmart 270, and Enamic displayed the highest ∆E values in wine (p < 0.05). Conclusions: The colour stability of tested SFRC CAD was comparable to other composite-based CAD/CAM materials, while IPS e.max exhibited the highest level of colour stability.

3.
Polymers (Basel) ; 16(12)2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38932063

ABSTRACT

This study aimed to evaluate the flexural strength (FS), surface wear, and optical properties of 3D-printed dental resins subjected to different post-printing conditions. A total of 240 specimens (2 × 2 × 25 mm³) were 3D-printed using resin materials for permanent (VaresoSmile Crown Plus) VSC and temporary (VaresoSmile Temp) VST restorations. Specimens underwent five post-printing conditions: no post-printing cure; post-cured in a Form Cure curing unit; Visio Beta Vacuum; Ivoclar Targis; or heat-cured (150 °C) for 30 min. Each group of specimens (n = 24) was tested either directly after post-curing, after 24 h of dry storage, or following hydrothermal accelerated aging in boiling water for 16 h. The three-point bending test was used to evaluate the FS. The two-body wear test was performed on 50 disc-shaped specimens (n = 5/group). Surface gloss and translucency were measured for permanent VSC specimens (n = 5/group). SEM/EDS and statistical analyses were performed. The Form Cure device yielded the highest FS and lowest wear depth (p < 0.05). Hydrothermal aging significantly reduced FS. There were no statistical differences in FS and wear values between materials subjected to same post-printing conditions. VSC groups exhibited similar optical properties across different post-printing treatments. Post-printing treatment conditions had a significant impact on the FS and wear of the 3D-printed resin, while optical properties remained unaffected.

4.
Eur J Dent ; 2024 May 14.
Article in English | MEDLINE | ID: mdl-38744336

ABSTRACT

OBJECTIVES: The aim of the study was to evaluate the mechanical properties and impact absorption capacity of prototype materials comprising ethylene vinyl acetate (EVA) of different hardness reinforced using different amounts of glass fibers (GFs), considering a buffer space. MATERIALS AND METHODS: Six prototype materials were made by adding E-GFs (5 and 10 wt%) to EVA with vinyl acetate (VA) contents of 9.4 wt% ("hard" or HA) and 27.5 wt% ("soft" or SO). Durometer hardness and tensile strength tests were performed to evaluate the mechanical properties of the materials. Moreover, an impact test was conducted using a customized pendulum impact tester to assess the impact absorption capacity (with or without a buffer space) of the specimens. RESULTS: The mechanical properties of the prototypes, namely, durometer hardness, Young's modulus, and tensile strength, were significantly higher in the HA group than in the SO group, regardless of the presence or added amount of GFs. The addition of GFs, particularly in a large amount (10 wt%), significantly increased these values. In terms of the impact absorption capacity, the original hardness of the EVA material, that is, its VA content, had a more substantial effect than the presence or absence of GFs and the added amount of GFs. Interestingly, the HA specimens with the buffer space exhibited significantly higher impact absorption capacities than the SO specimens. Meanwhile, the SO specimens without the buffer space exhibited significantly higher impact absorption capacities than the HA specimens. Moreover, regardless of the sample material and impact distance, the buffer space significantly improved impact absorption. In particular, with the buffer space, the impact absorption capacity increased with the added amount of GFs. CONCLUSION: The basic mechanical properties, including durometer hardness, Young's modulus, and tensile strength, of the EVA prototype were significantly increased by reducing the amount of VA regardless of the presence or added amount of GFs. Adding GFs, particularly in large amounts, significantly increased the values of aforementioned mechanical properties. Impact absorption was significantly affected by the hardness of the original EVA material and enhanced by the addition of the buffer space. The HA specimen had a high shock absorption capacity with the buffer space, and the SO specimen had a high shock absorption capacity without the buffer space. With the buffer space, impact absorption improved with the amount of added GFs.

5.
J Clin Exp Dent ; 16(3): e333-e342, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38600927

ABSTRACT

Background: Dual-cure resin-based luting materials are increasingly favored in clinical applications due to their capacity to establish a strong bond with natural tooth structure and restorations. This study aimed to examine certain physical and handling characteristics of newly developed experimental dual-cure luting resins reinforced with short fibers (SFRCs) and compare them with commercially available dual-cure luting resins. Material and Methods: Seven dual-cure luting materials were tested (Relyx Ultimate, Duo-Link, eCEMENT, Variolink Esthetic, G-CEM LinkForce, experimental SFRC1, experimental SFRC2). Fourier transform infrared spectroscopy (FTIR) was utilized to determine the degree of monomer conversion (DC%) in the self and light-curing protocol. A rotating disk rheometer measured viscosity at room temperature (22°C) and simulated mouth temperature (35°C). Fracture toughness, flexural strength, and flexural modulus were evaluated using a 3-point bending test. Each luting resin was subjected to the examination of its surface microstructure using scanning electron microscopy (SEM). Analysis of variance (ANOVA) at a significance level of (p = 0.05) was conducted to analyze data. Results: It was revealed that DC% of the tested dual-cure resins was significantly (p< 0.05) affected by the curing mode, the dual-cure SFRC2 having the highest and Relyx having the lowest DC (64%, and 41% respectively). The viscosity of all tested materials decreased with increasing temperature. SFRC2 demonstrated the highest fracture toughness (2.3 MPa m1/2), while Relyx Ultimate, Duo-Link, and eCEMENT exhibited the lowest values (≈ 1 MPa m1/2)(p< 0.05). Both SFRCs and G-CEM link-force exhibited the highest flexural strength values, and SFRCs resulted in the highest flexural modulus values (p<0.05). Conclusions: The experimental fiber-reinforced dual-cure luting resins exhibited superior DC%, fracture toughness, and flexural properties, yet, SFRC2 showed the highest viscosity at elevated temperature. These results highlight the capability of short fiber reinforcement to enhance the mechanical properties of dual-cured resin-based luting materials without compromising handling characteristics. Key words:Dual-cure luting resin; short fibers; degree of conversion; viscosity; fracture toughness; flexural properties.

6.
Polymers (Basel) ; 16(5)2024 Feb 21.
Article in English | MEDLINE | ID: mdl-38475274

ABSTRACT

In recent years, composite resin materials have been the most frequently used materials for direct restorations of posterior teeth. These materials have some clinically relevant limitations due to their lack of fracture toughness, especially when used in larger cavities with high volume factors or when utilized as direct or indirect overlays or crown restorations. Recently, short-fiber-reinforced composite materials have been used in bi-structure restorations as a dentine substituting material due to their superior mechanical properties; however, there is no scientific consensus as to whether they can be used as full restorations. The aim of our review was to examine the available literature and gather scientific evidence on this matter. Two independent authors performed a thorough literature search using PubMed and ScienceDirect up until December 2023. This study followed the PRISMA guidelines, and the risk of bias was assessed using the QUIN tool. The authors selected in vitro studies that used short-fiber-reinforced composite materials as complete restorations, with a conventional composite material as a comparison group. Out of 2079 potentially relevant articles, 16 met our inclusion criteria. All of the included studies reported that the usage of short-fiber-reinforced composites improved the restoration's load-bearing capacity. Fifteen of the included publications examined the fracture pattern, and thirteen of them reported a more favorable fracture outcome for the short-fiber-reinforced group. Only one article reported a more favorable fracture pattern for the control group; however, the difference between groups was not significant. Within the limitations of this review, the evidence suggests that short-fiber-reinforced composites can be used effectively as complete restorations to reinforce structurally compromised teeth.

7.
Polymers (Basel) ; 16(5)2024 Feb 23.
Article in English | MEDLINE | ID: mdl-38475291

ABSTRACT

The aim of this study was to compare the mechanical properties and ion release from a commercially available resin-modified glass ionomer cement to a formulation reinforced by the addition of short glass fibres at various percentages. Methods: Three experimental groups were prepared by adding a mass ratio of 10%, 15% and 20% of short glass fibres to the powder portion of the cement from a capsule (GC Fuji II LC), while the control group contained no fibres. Microhardness (n = 12), fracture toughness, and flexural, compressive and diametral tensile strength (n = 8) were evaluated. To study ion release, readings were obtained utilising fluoro-selective and calcium-selective electrodes after 24 h, 7 days and 30 days (n = 12). The spatial distribution of fibres within the material was evaluated through scanning electron microscopy. The data were analysed using one-way ANOVA with a Bonferroni adjustment. Results: The findings suggest that elevating fibre weight ratios to 20 wt% results in improved mechanical properties (p < 0.05) in microhardness, flexural strength, diametral tensile strength and fracture toughness. In terms of ion release, a statistically significant difference (p < 0.001) was observed between the groups at the conclusion of 24 h and 7 days, when the fluoride release was much higher in the control group. However, after 30 days, no significant distinction among the groups was identified (p > 0.05). Regarding calcium release, no statistically significant differences were observed among the groups at any of the evaluated time points (p > 0.05). SEM showed the fibres were homogeneously incorporated into the cement in all experimental groups. Conclusions: Resin-modified glass ionomer enhanced with short glass fibres at a weight loading of 20% showcased the most favourable mechanical properties while concurrently maintaining the ability to release fluoride and calcium after a 30-day period.

8.
Int J Prosthodont ; 0(0): 1-19, 2024 Mar 13.
Article in English | MEDLINE | ID: mdl-38477845

ABSTRACT

PURPOSE: The aim of this study was to evaluate the influence of restoration bonding and type of preparation on load bearing capacity of a tooth restored with indirect glass ceramic or hybrid ceramic occlusal veneer restoration. MATERIALS AND METHODS: Occlusal surfaces of extracted human molar teeth were prepared for indirect occlusal veneers with or without circumferential chamfer. The occlusal veneers were milled either from CAD/CAM hybrid ceramic (HC) Cerasmart (GC), or lithium-disilicate glass ceramic (LDGC) IPS e.max CAD (Ivoclar Vivadent) blocks. Finalized veneers were bonded to teeth following manufacturers' instructions or according to the technique for the intended deteriorated bonding using n-hexane wax solution preconditioning on restorations (n=8/group). The ultimate fracture load was recorded, and fracture types were analyzed and classified visually. Statistical analysis was performed using one-way ANOVA. RESULTS: The highest fracture load was recorded in teeth with bonded LDGC veneer (p≤0.0007). The bonded HC veneers had only marginally higher fracture load compared to non-bonded veneers. In all groups with deteriorated bonding, veneers loosened without tooth fracture whereas in the bonded veneer groups tooth fractures were observed, especially in teeth restored with LDGC material. CONCLUSIONS: Bonded LDGC occlusal veneers have high load bearing capacity which exceeds the fracture resistance of tooth structure. Circumferential chamfer preparation for an occlusal veneer has no influence on fracture load of a restored tooth.

9.
J Mech Behav Biomed Mater ; 152: 106450, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38325167

ABSTRACT

The aim of this study was to evaluate a novel approach for measuring the polymerization shrinkage of dental resin composites - measurement of sample depth variation. This new method was compared with two testing methodologies used for assessing the polymerization shrinkage (buoyancy and strain gauge methods). Eleven commercial resin composites were investigated (EverX Posterior; EverX Flow Bulk & Dentin; G-aenial Anterior, Posterior, A'chord & Universal Injectable; Filtek One Bulk Fill & Universal Restorative; SDR + Flow and Aura Bulk Fill). In addition, filler content (wt. %), flexural modulus, and the degree of conversion were evaluated. Shrinkage values, obtained by the buoyancy method, are greater than shrinkage evaluated by the strain gauge. There are significant differences in polymerization shrinkage among the tested resin composite materials. There is a strong correlation between the newly proposed method of shrinkage measurement and the buoyancy method (r2 = 0.8; p < 0.01). There is no correlation between volumetric shrinkage measurement (depth changes and buoyancy method) and linear strain measurement. Volumetric filler amount correlates with shrinkage values evaluated by all three methods. The degree of conversion for the tested resin composites ranges from 36 % to 52 %. There are some differences (around 10 %) between the filler content (wt. %) measured by the ashing-in-air method and the data given by the manufacturers. The highest flexural modulus is 14.8 GPa and the lowest 6.6 GPa. New formulations may introduce unknown relationships between the fundamental properties of dental resin composites.


Subject(s)
Gastropoda , Animals , Polymerization
10.
Odontology ; 2024 Feb 23.
Article in English | MEDLINE | ID: mdl-38393515

ABSTRACT

The purpose of this clinical trail was to assess the clinical behavior of posterior composite restorations supported by a substantial foundation of flowable short fiber-reinforced composite SFRC (everX Flow, GC, Japan) used without proximal surface coverage with particulate filler resin composite (PFC). Seventy patients (20 males, 50 females; mean age: 30 ± 10 years) were randomly enrolled in this trial. Patients received direct restorations of either SFRC covered only on the occlusal surface (1-2 mm) by conventional PFC composite (G-ænial Posterior, GC), or plain conventional PFC composite without fiber-reinforcement, in Class II cavities in premolar and molar vital teeth. One operator made all restorations using one-step, self-etch bonding agent (G-ænial Bond, GC) according to manufacturers' recommendations. Two blinded trained operators evaluated the restorations at baseline, at 6, 12 and 18 months using modified USPHS criteria. Results indicated that, in both groups and at different follow-up intervals, according to evaluated criteria, restorations were rated mostly with best score (Alpha) (p > 0.05). For the marginal integrity after 6 months, a single case in the intervention [increased to 3 (8.8%) after 18 months] and 3 (9.7%) cases of the control group [increased to 4 (12.9%) after 18 months] had Bravo score but with no significant difference (p > 0.05). For color match measured after 6 and 18 months, three (8.8%) cases had Bravo score in the intervention group. The use of flowable SFRC composite without any PFC surface coverage proximally in Class II restorations demonstrated satisfactory clinical outcome throughout the 18-month follow-up.

11.
J Prosthodont Res ; 2024 Jan 29.
Article in English | MEDLINE | ID: mdl-38281759

ABSTRACT

PURPOSE: To investigate the effects of the number of ethylene oxide units in bis-EMA on the physical properties of additively manufactured occlusal splints. METHODS: Seven experimental materials containing bis-EMAs with three and 10 ethylene oxide units (BE3 and BE10, respectively) were prepared at different BE10 content rates (BE10-0%, -20%, -30%, -40%, -50%, -60%, and -80%). Half the specimens of each material were aged in boiling water. Flexural strength (FS), flexural modulus (FM), fracture toughness (FT), microwear depth (MD), degree of conversion (DC), water sorption (WSP), water solubility (WSL), color difference between non-aged and aged series (ΔE), and translucency (TP) were evaluated. All the evaluated properties other than FS and MD were analyzed by 1-way ANOVA and Tukey's post hoc analysis, while FS and MD were analyzed by Kruskal-Wallis's test and Bonferroni correction (α=0.05). RESULTS: BE10-80% revealed the lowest FS (P < 0.01 for BE10-0%, -20%, and -30%) and FM (P < 0.01, for all), while revealing the highest DC, WSP, WSL (P < 0.01 for all) and TP (P < 0.01 for all other than BE10-60%). BE10-50% showed the highest FT (P < 0.01 for all). BE10-50%, -60%, and -80% revealed significantly lower ΔE than others (P < 0.01) and lower MD than BE10-0% (P < 0.05). Regardless of the BE10 content, FS, FM, and FT decreased with aging. CONCLUSIONS: The number of ethylene oxide units affects the physical properties of additively manufactured occlusal splints. The higher number of ethylene oxide units in bis-EMA enhanced the microwear resistance, DC, WSP, WSL, color stability, and translucency, whereas it deteriorated the FS and FM.

12.
J Prosthodont Res ; 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38296526

ABSTRACT

PURPOSE: To evaluate the effect of chemical, mechanical, and combination surface treatments on the shear bond strength (SBS) of autopolymerizing repair resins to conventional heat-cured, computer aided design (CAD)-computer aided manufacturing (CAM) milled, and three-dimensionally (3D) printed denture base materials. METHODS: Specimens were fabricated and divided according to the surface treatment as follows: no surface treatment (control group), monomer treatment (monomer group), resin remover treatment (resin remover group), roughening with 180 FEPA grit abrasive paper followed by monomer treatment (180-grit plus monomer group), and air particle abrasion (air abrasion group). Autopolymerizing resin cylinders were attached before accelerated aging of the specimens in water at 100 °C for 16 h. The SBS was tested using a universal testing machine. Surface roughness was evaluated using a 3D optical profilometer. Scanning electron microscopy (SEM) and stereomicroscopy were used for surface analysis. Data was collected and analyzed using analysis of variance (ANOVA) and Kruskall-Wallis tests (α = 0.05). RESULTS: The denture base material and surface treatment significantly affected the SBS. The milled Temp Basic Tissue demonstrated the highest SBS values across all surface treatments, whereas the two 3D-printed denture base materials exhibited the lowest SBS values. CONCLUSIONS: The bond strength of CAD-CAM-milled denture base resins to autopolymerizing repair resins is comparable to that of heat-cured resins. Surface roughening using air particle abrasion or 180-grit carbide paper can enhance the bond strength of the autopolymerizing repair resin to 3D-printed denture base materials.

13.
Dent Mater J ; 43(2): 164-171, 2024 Mar 29.
Article in English | MEDLINE | ID: mdl-38296512

ABSTRACT

This study investigated the effects of low-temperature degradation (LTD) on the L*, a*, and b* values of highly translucent zirconia crowns. Four types of zirconia disks with different yttria contents (IPS e.max ZirCAD LT, IPS e.max ZirCAD MT, IPS e.max ZirCAD MT Multi, IPS e.max ZirCAD Prime, Ivoclar) and two shades (A2 and BL) were used. A crown was manufactured using four types of zirconia and LTD treated. Color measurements were performed, and the color difference (ΔE00) before and after LTD was calculated. The microstructure was determined through X-ray fluorescence and X-ray diffractometry. Highly translucent zirconia crowns showed greater changes in the a* and b* values than in the L* value after LTD, regardless of the shade. The Multi2 crowns exhibited a discernible color change due to the LTD treatment. The X-ray fluorescence results did not reveal any apparent change in the microstructure between sintering programs for all zirconia specimens.


Subject(s)
Crowns , Yttrium , Zirconium , Temperature , Zirconium/chemistry , Materials Testing , Ceramics/chemistry , Color , Surface Properties
14.
Dent Mater J ; 43(2): 155-163, 2024 Mar 29.
Article in English | MEDLINE | ID: mdl-38296513

ABSTRACT

The aim of this study was to compare two testing methodologies employed for assessing the polymerization shrinkage stress of dental resin composites. Ten commercial resin composites were investigated (EverX Posterior & Flow; G-ænial Anterior, Posterior, A'CHORD & Universal Injectable; Filtek One Bulk Fill & Universal Restorative; SDR flow+ and Aura Bulk Fill). Photoelastic and contraction forces measurement methods were performed. The slope of the linear trendline and C-factor of specimens were calculated. The shrinkage stress values (range between: 6.4-13.4 MPa) obtained by the photoelastic method were higher for all resin composites than the values obtained by contraction forces measurements (range between 1.2-4.8 MPa). However, there was a strong linear correlation between these methods (r=0.8). The use of both investigated methods revealed important information about the shrinkage behavior of the restorative resin composites.


Subject(s)
Composite Resins , Dental Materials , Polymerization , Dental Stress Analysis , Materials Testing
15.
J Prosthodont Res ; 68(1): 105-113, 2024 Jan 16.
Article in English | MEDLINE | ID: mdl-37164657

ABSTRACT

PURPOSE: The aim of this study is to evaluate the mechanical and adhesive properties of three different resin cements with bioactive glass (BAG) incorporated in two different ratios. METHODS: BAG was added to different resin cements (3M Rely-X Ultimate, GC Link Ace, and GC Link Force) in different ratios (5% and 10% by weight). The three-point flexural strength, microhardness, and bond strength properties were evaluated. The fracture types of the groups were then analyzed using a stereo microscope. The data were analyzed using a multifactorial analysis of variance and Tukey's post-hoc tests (α < 0.05). RESULTS: The addition of BAG reduced the flexural strength of the resin cements (P < 0.05).The effect of BAG addition on the Vickers microhardness value was significantly different for each cement group (P < 0.05). In addition, with the exception of the GC link force group (10% BAG addition), the BAG addition decreased the bond strength of cements to dentin in all the groups (P = 0.171). CONCLUSIONS: The results of this study confirmed that different resin cements comprising different ratios of BAG exhibited different flexural strength, hardness, and bond-strength properties. Since the bond strength values increased with the addition of 10% BAG in the GC Link Force cement group, the effects of different BAG compositions could be worth investigating in future studies.


Subject(s)
Dental Bonding , Resin Cements , Resin Cements/chemistry , Dental Bonding/methods , Dental Cements/chemistry , Glass Ionomer Cements/chemistry , Materials Testing , Surface Properties , Dentin , Glass , Dental Stress Analysis
16.
Dent Mater J ; 42(6): 800-805, 2023 Nov 29.
Article in English | MEDLINE | ID: mdl-37793824

ABSTRACT

This study aimed to investigate the effect of low-temperature degradation (LTD) on the mechanical properties of additive-manufactured zirconia. In addition, the mechanical properties of additive-manufactured were compared with those before aging under similar experimental conditions. This study prepared stereolithography apparatus fabricated zirconia specimens with flexural strength, modulus of elasticity, Vickers hardness, and fracture toughness. The specimen position data were set as parallel (0°), diagonal (45°), and perpendicular (90°) to the direction of the building. The LTD condition was 5 h under 134ºC and 0.2 MPa in an autoclave. It was found that the 0° direction differed significantly from all other conditions before and after aging, and the highest flexural strength was obtained when the additive specimen was manufactured perpendicular to the building direction. However, the results indicate that there is a negligible effect of aging on the mechanical properties of additive-manufactured zirconia.


Subject(s)
Cold Temperature , Zirconium , Temperature , Materials Testing , Surface Properties , Ceramics , Yttrium
17.
Clin Oral Investig ; 27(11): 6865-6877, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37821653

ABSTRACT

OBJECTIVES: To investigate the impact of simulated gastric acid on the surface properties of lithium disilicate-reinforced glass-ceramics and zirconia-reinforced lithium silicate glass-ceramic after certain polishing and glazing procedures. MATERIALS AND METHODS: Four different types of square-shaped specimens (10 × 10 × 2 mm3, n = 13) were manufactured: lithium disilicate-reinforced glass-ceramic milled and polished (LDS-P); milled, polished, and glazed (LDS-PG); milled, glazed, and no polishing (LDS-G); and milled and polished zirconia-reinforced lithium silicate glass-ceramic (ZR-LS). Specimens were immersed in hydrochloride acid (HCl 0.06 M, pH 1.2) to simulate gastric acid irritation and stored in the acid for 96 h in 37 °C. Specimen weight, surface gloss, Vickers surface microhardness and surface roughness (Ra, Rq, with optical profilometer), and surface roughness on nanometer level (Sq, Sal, Sq/Sal, Sdr, Sds with atomic force microscope) were measured before and after the acid immersion. RESULTS: ZR-LS specimens lost significantly more weight after acid immersion (p = 0.001), also surface microhardness of ZR-LS was significantly reduced (p = 0.001). LDS-G and LDS-PG showed significantly lower surface roughness (Sa, Sq) values compared to LDS-P before (p ≤ 0.99) and after (p ≤ 0.99) acid immersion and ZR-LS after acid immersion (p ≤ 0.99). CONCLUSIONS: Gastric acid challenge affects the surface properties of lithium disilicate-reinforced glass-ceramic and zirconia-reinforced lithium silicate glass-ceramic. Glazing layer provides lower surface roughness, and the glazed surface tends to smoothen after the gastric acid challenge. CLINICAL RELEVANCE: Surface finish of lithium disilicate-reinforced glass-ceramic and zirconia-reinforced lithium silicate glass-ceramic has a clear impact on material's surface properties. Gastric acidic challenge changes surface properties but glazing seems to function as a protective barrier. Nevertheless, also glazing tends to smoothen after heavy gastric acid challenge. Glazing can be highly recommended to all glass-ceramic restorations but especially in patients with gastroesophageal reflux disease (GERD) and eating disorders like bulimia nervosa.


Subject(s)
Gastric Acid , Lithium , Humans , Materials Testing , Computer-Aided Design , Dental Porcelain/chemistry , Ceramics/chemistry , Zirconium/chemistry , Silicates , Surface Properties
18.
Dent Mater ; 39(10): 957-963, 2023 10.
Article in English | MEDLINE | ID: mdl-37666693

ABSTRACT

OBJECTIVE: To evaluate and compare the mechanical properties, water sorption, water solubility, and degree of double bond conversion of three different commercially available three-dimensional (3D) printing resins used for the fabrication of flexible occlusal splints. METHODS: A digital printer was used to generate specimens from the evaluated splint materials (KeySplint Soft, IMPRIMO LC Splint flex, and V-Print splint comfort). The specimens were equally divided and tested either dry or after water storage at 37 °C for 30 days. A three-point bending test was used to assess flexural strength, elastic modulus, and fracture toughness. A two-body wear test was performed using a dual-axis chewing simulator. Water sorption and water solubility were measured after 30 days. The degree of double bond conversion was determined by FTIR-spectrometry. All data for the evaluated properties were collected and statistically analyzed. RESULTS: Both material and storage conditions had a significant effect on the flexural strength (P < 0.001), elastic modulus (P < 0.001), fracture toughness (P < 0.001), and wear (P < 0.001). The highest water sorption was noticed with IMPRIMO LC Splint flex (1.9 ± 0.0 %), while V-Print splint comfort displayed the lowest water solubility (0.2 ± 0.0 %). For the degree of conversion, it was statistically non-significant among the different materials (P = 0.087). SIGNIFICANCE: Different flexible 3D-printed splints available in the market displayed variations in the evaluated properties and clinicians should consider these differences when choosing occlusal device materials. Among the tested flexible splint materials, KeySplint Soft had the greatest flexural strength, elastic modulus, fracture toughness, wear resistance, and degree of conversion. It also showed the lowest water sorption.


Subject(s)
Occlusal Splints , Research Design , Elastic Modulus , Printing, Three-Dimensional , Water
19.
Eur J Oral Sci ; 131(5-6): e12951, 2023.
Article in English | MEDLINE | ID: mdl-37641165

ABSTRACT

The aim of this study was to evaluate load-bearing capacity and wear performance of experimental short fiber-reinforced composite (SFRC) and conventional lithium-disilicate CAD/CAM fabricated fixed partial dentures (FPDs). Two groups (n = 12/group) of three-unit CAD/CAM fabricated posterior FPDs were made. The first group used experimental SFRC blocks, and the second group fabricated from lithium-disilicate (IPS e.max CAD). All FPDs were luted on a zirconia testing jig with dual-curing resin cement. Half of FPDs per group were quasi-statically loaded until fracture. The other half experienced cyclic fatigue aging (100.000 cycles, Fmax = 500 N) before loading quasi-statically until fracture. Fracture mode was examined using SEM. Wear test was performed using 15,000 loading cycles. Both material type and aging had a significant effect on the load-bearing capacity of FPDs. Experimental SFRC CAD without fatigue aging had significantly the highest load-bearing capacity (2096 ± 149N). Cyclic fatigue aging decreased the load-bearing capacity of the SFRC group (1709 ± 188N) but increased it for the lithium-disilicate group (1546 ± 155N). Wear depth values of SFRC CAD (29.3µm) were significantly lower compared to lithium-disilicate (54.2µm). Experimental SFRC CAD demonstrated the highest load-bearing capacity before and after cyclic fatigue aging, and superior wear behavior compared to the control material.


Subject(s)
Ceramics , Lithium , Dental Porcelain , Weight-Bearing , Computer-Aided Design , Denture, Partial, Fixed , Materials Testing , Dental Stress Analysis , Dental Restoration Failure
20.
Acta Odontol Scand ; 81(6): 491-498, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37192014

ABSTRACT

OBJECTIVES: Kombuchas and other tea-based beverages are often perceived as healthy products despite the lack of knowledge on their effects on oral health. This in vitro study determined the erosive potential of commercial kombuchas, and ice teas compared to cola drinks. MATERIALS AND METHODS: The pH and fluoride content of 7 kombuchas and 18 tea drinks were measured with ion-selective electrodes. Calcium dissolution from hydroxyapatite grains was quantified by atomic absorption spectroscopy after beverage exposure. The effect of beverages on the enamel surface was visualized by scanning electron microscopy (SEM). Distilled water, and cola drinks were used as negative and positive controls. RESULTS: The kombuchas exhibited lower pH values (2.82-3.66) than the ice teas (2.94-4.86), but still higher than the cola drinks (2.48-2.54). The fluoride concentration varied between 0.05 and 0.46 ppm and for 7 beverages the concentration was below the detection limit. The calcium release for kombuchas was 198-746 mg/l, for ice teas 16.1-507 mg/l, and for cola drinks 57.7-71.9 mg/l. Twenty-two beverages had a significantly greater calcium release than the cola drinks (p = .009-.014). The surface etching of the enamel was seen in the SEM analysis after beverage exposure. CONCLUSIONS: Tea-based beverages have even higher erosive potential than cola drinks. Kombuchas especially, displayed a considerable erosive potential.


Subject(s)
Ice , Tooth Erosion , Humans , Ice/analysis , Calcium , Fluorides , Tooth Erosion/etiology , Beverages , Carbonated Beverages/adverse effects , Tea , Hydrogen-Ion Concentration
SELECTION OF CITATIONS
SEARCH DETAIL
...