1.
J Arthroplasty ; 2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38677348

ABSTRACT

BACKGROUND: The influence of tibial slope on tibial component migration following total knee arthroplasty has not been widely studied, although excessive posterior slope has been implicated in some failures. As implant micromotion measured with radiostereometric analysis can indicate successful fixation, the purpose of this study was to determine the associations between tibial slope, tibial component migration, and inducible displacement. METHODS: Radiostereometric analyses at 6 visits over 2 years quantified implant migration for 200 cemented total knee arthroplasties. Longitudinal data analysis examined the influence of postoperative tibial slope on implant migration (overall maximum total point motion (MTPM) migration and anterior-posterior tilt migration), accounting for age, sex, and body mass index. The correlations of tibial slope with 1-year migration, continuous migration, and inducible displacements were also examined. Additionally, the amount of change in slope was compared to migration. RESULTS: The mean posterior tibial slope was 8.0° (standard deviation [SD] 3.8°) preoperatively and 3.8° (SD 3.1°) postoperatively, with a mean reduction in slope of 4.2° (SD 4.7°). Postoperative tibial slope (range 14.0° posterior slope to 3.4° anterior slope) was not associated with longitudinal overall migration (P = .671) or anterior-posterior tilt migration (P = .704). There was no association between postoperative tibial slope and migration at 1 year postoperatively (P = .441 for MTPM migration, P = .570 for tilt migration), change in migration from 1 to 2 years (P = .951), or inducible displacement (P = .970 MTPM, P = .730 tilt). The amount of change in tibial slope was also not associated with migration or inducible displacement. CONCLUSIONS: Residual and change in postoperative tibial slope were not associated with implant migration into tilt or overall migration, or inducible displacement for a single implant design. These findings support positioning tibial implants in a range of slopes, which may support patient-specific approaches to implant alignment.

2.
J Appl Biomech ; 40(2): 129-137, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38237574

ABSTRACT

As markerless motion capture is increasingly used to measure 3-dimensional human pose, it is important to understand how markerless results can be interpreted alongside historical marker-based data and how they are impacted by clothing. We compared concurrent running kinematics and kinetics between marker-based and markerless motion capture, and between 2 markerless clothing conditions. Thirty adults ran on an instrumented treadmill wearing motion capture clothing while concurrent marker-based and markerless data were recorded, and ran a second time wearing athletic clothing (shorts and t-shirt) while markerless data were recorded. Differences calculated between the concurrent signals from both systems, and also between each participant's mean signals from both asynchronous clothing conditions were summarized across all participants using root mean square differences. Most kinematic and kinetic signals were visually consistent between systems and markerless clothing conditions. Between systems, joint center positions differed by 3 cm or less, sagittal plane joint angles differed by 5° or less, and frontal and transverse plane angles differed by 5° to 10°. Joint moments differed by 0.3 N·m/kg or less between systems. Differences were sensitive to segment coordinate system definitions, highlighting the effects of these definitions when comparing against historical data or other motion capture modalities.


Subject(s)
Motion Capture , Running , Adult , Humans , Biomechanical Phenomena , Knee Joint , Clothing , Motion
3.
Acta Orthop ; 94: 577-587, 2023 11 30.
Article in English | MEDLINE | ID: mdl-38038237

ABSTRACT

BACKGROUND AND PURPOSE: This updated meta-analysis evaluates the migration pattern of the tibial component of primary total knee replacements measured with radiostereometric analysis (RSA). We aimed to evaluate whether 6-month maximum total point motion (MTPM) values could be used instead of 1-year MTPM for RSA threshold testing and to present the pooled migration patterns for different implant designs that can be used as a benchmark. PATIENTS AND METHODS: The search included all published RSA studies on migration patterns of tibial components until 2023. Study groups were classified according to their prosthesis brand, fixation, and insert (PFI). Sub-analyses were performed to compare the mean tibial component migration patterns of different implant variables, stratified according to fixation. RESULTS: 96 studies (43 new studies), including 197 study groups and 4,706 knees, were included. Most migration occurred within the first 6 postoperative months (126 study groups: mean 0.58 mm, 95% confidence interval [CI] 0.50-0.65), followed by minimal migration between 6 and 12 months (197 study groups: mean 0.04 mm, CI 0.03-0.06), irrespective of the fixation method used. Distinct migration patterns were observed among the different fixation methods. No differences were found in migration patterns among cemented components in any of the sub-group analyses conducted. For uncemented implants, trabecular metal surfaced components seemed to migrate less than porous-coated or uncoated components Conclusion: Based on the small difference between MTPM values at 6 months and 1 year, MTPM at 6 months could be used instead of MTPM at 1 year for RSA threshold testing. The pooled migration patterns can be used as benchmark for evaluation of new implants by defining fixation-specific RSA thresholds when combined with implant survival.


Subject(s)
Knee Prosthesis , Osteoarthritis, Knee , Humans , Osteoarthritis, Knee/surgery , Follow-Up Studies , Prosthesis Failure , Prosthesis Design , Radiostereometric Analysis/methods
4.
Acta Orthop ; 94: 555-559, 2023 11 30.
Article in English | MEDLINE | ID: mdl-38032252

ABSTRACT

BACKGROUND AND PURPOSE: The low radiation biplanar X-ray imager (EOS imaging, Paris, France) scans patients in a weight-bearing position, provides calibrated images, and limits radiation, an asset for serial radiostereometric analysis (RSA) studies. RSA in vivo precision values have not been published for this type of imaging system, thus the goal of this study was to assess the precision of RSA in vivo utilizing a low radiation biplanar imager. PATIENTS AND METHODS: At a mean of 5 years post-surgery (range 1.4-7.5 years), 15 total knee arthroplasty (TKA) participants (mean age 67 years at the time of imaging, 12 female, 3 male) with RSA markers implanted during index surgery were scanned twice at the same visit in the EOS imager. Precision of marker-based analysis was calculated by comparing the position of the implant relative to the underlying bone between the 2 examinations. RESULTS: The 95% limit of precision was 0.11, 0.04, and 0.15 mm along the x, y, and z axes, respectively and 0.15°, 0.20°, and 0.14° around the same axes. CONCLUSION: This precision study has shown an in vivo RSA precision of ≤ 0.15 mm and ≤ 0.20°, well within published uniplanar values for conventional arthroplasty RSA, with the added benefit of weight-bearing imaging, a lower radiation dose, and without the need for a reference object during the scan.


Subject(s)
Arthroplasty, Replacement, Knee , Humans , Male , Female , Aged , Radiostereometric Analysis , X-Rays
5.
J Biomech ; 152: 111556, 2023 05.
Article in English | MEDLINE | ID: mdl-37004391

ABSTRACT

Balance tests have clinical utility in identifying balance deficits and supporting recommendations for appropriate treatments. Motion capture technology can be used to measure whole-body kinematics during balance tasks, but to date the high technical and financial costs have limited uptake of traditional marker-based motion capture systems for clinical applications. Markerless motion capture technology using standard video cameras has the potential to provide whole-body kinematic assessments with clinically accessible technology. Our aim was to quantify poses and movement strategies during static balance tasks (tandem stance, single limb stance, standing hip abduction, and quiet standing on foam with eyes closed) using video-based markerless motion capture software (Theia3D) and principal component analysis to examine the associations with age, body mass index (BMI) and sex. In 30 healthy adults, the mean poses for all balance tasks had at least one principal component (PC) that differed significantly by sex. Age was significantly associated with the PC describing leg height for the hip abduction task and erect posture for the quiet standing task. BMI was significantly associated with the PC capturing knee flexion in the single leg stance task. The movement strategies used to maintain balance showed significant differences by sex for the tandem stance pose. BMI was correlated with PCs for movement strategies for hip abduction and quiet standing tasks. Results from this study demonstrate how markerless motion capture technology could be used to augment analyses of balance both in the clinic and in the field.


Subject(s)
Motion Capture , Movement , Adult , Humans , Biomechanical Phenomena , Principal Component Analysis , Lower Extremity
6.
J Biomech ; 141: 111182, 2022 08.
Article in English | MEDLINE | ID: mdl-35749889

ABSTRACT

Markerless motion capture allows whole-body movements to be captured without the need for physical markers to be placed on the body. This enables motion capture analyses to be conducted in more ecologically valid environments. However, the influences of varied clothing on video-based markerless motion capture assessments remain largely unexplored. This study investigated two types of clothing conditions, "Sport" (gym shirt and shorts) and "Street" (unrestricted casual clothing), on gait parameters during overground walking by 29 participants at self-selected speeds using markerless motion capture. Segment lengths, gait spatiotemporal parameters, and lower-limb kinematics were compared between the two clothing conditions. Mean differences in segment length for the forearm, upper arm, thigh, and shank between clothing conditions ranged from 0.2 cm for the forearm to 0.9 cm for the thigh (p < 0.05 for thigh and shank) but below typical marker placement errors (1 - 2 cm). Seven out of 9 gait spatiotemporal parameters demonstrated statistically significant differences between clothing conditions (p < 0.05), however, these differences were approximately ten times smaller than minimal detectable changes in movement-related pathologies including multiple sclerosis and cerebral palsy. Hip, knee, and ankle joint angle root-mean-square deviation values averaged 2.6° and were comparable to previously reported average inter-session variability for this markerless system (2.8°). The results indicate that clothing, a potential limiting factor in markerless motion capture performance, would negligibly alter meaningful clinical interpretations under the conditions investigated.


Subject(s)
Gait , Walking , Biomechanical Phenomena , Clothing , Humans , Motion
7.
Bone Joint J ; 104-B(4): 444-451, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35360938

ABSTRACT

AIMS: Thresholds of acceptable early migration of the components in total knee arthroplasty (TKA) have traditionally ignored the effects of patient and implant factors that may influence migration. The aim of this study was to determine which of these factors are associated with overall longitudinal migration of well-fixed tibial components following TKA. METHODS: Radiostereometric analysis (RSA) data over a two-year period were available for 419 successful primary TKAs (267 cemented and 152 uncemented in 257 female and 162 male patients). Longitudinal analysis of data using marginal models was performed to examine the associations of patient factors (age, sex, BMI, smoking status) and implant factors (cemented or uncemented, the size of the implant) with maximum total point motion (MTPM) migration. Analyses were also performed on subgroups based on sex and fixation. RESULTS: In the overall group, only fixation was significantly associated with migration (p < 0.001). For uncemented tibial components in males, smoking was significantly associated with lower migration (p = 0.030) and BMI approached significance (p = 0.061). For females with uncemented components, smoking (p = 0.081) and age (p = 0.063) approached significance and were both associated with increased migration. The small number of self-reported smokers in this study warrants cautious interpretation and further investigation. For cemented components in females, larger sizes of tibial component were significantly associated with increased migration (p = 0.004). No factors were significant for cemented components in males. CONCLUSION: The migration of uncemented tibial components was more sensitive to patient factors than cemented implants. These differences were not consistent by sex, suggesting that it may be of value to evaluate female and male patients separately following TKA. Cite this article: Bone Joint J 2022;104-B(4):444-451.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Bone Cements , Female , Follow-Up Studies , Humans , Male , Osteoarthritis, Knee/diagnostic imaging , Osteoarthritis, Knee/surgery , Prosthesis Design , Prosthesis Failure , Radiostereometric Analysis , Treatment Outcome
8.
J Biomech ; 127: 110665, 2021 10 11.
Article in English | MEDLINE | ID: mdl-34380101

ABSTRACT

Kinematic analysis is a useful and widespread tool used in research and clinical biomechanics for the quantification of human movement. Common marker-based optical motion capture systems are time intensive and require highly trained operators to obtain kinematic data. Markerless motion capture systems offer an alternative method for the measurement of kinematic data with several practical benefits. This work compared the kinematics of human gait measured using a deep learning algorithm-based markerless motion capture system to those from a standard marker-based motion capture system. Thirty healthy adult participants walked on a treadmill while data were simultaneously recorded using eight video cameras and seven infrared optical motion capture cameras, providing synchronized markerless and marker-based data for comparison. The average root mean square distance (RMSD) between corresponding joint centers was less than 2.5 cm for all joints except the hip, which was 3.6 cm. Lower limb segment angles relative to the global coordinate system indicated the global segment pose estimates from both systems were very similar, with RMSD of less than 5.5° for all segment angles except those that represent rotations about the long axis of the segment. Lower limb joint angles captured similar patterns for flexion/extension at all joints, ab/adduction at the knee and hip, and toe-in/toe-out at the ankle. These findings indicate that the markerless system would be a suitable alternative technology in cases where the practical benefits of markerless data collection are preferred.


Subject(s)
Gait , Walking , Adult , Ankle Joint , Biomechanical Phenomena , Humans , Motion
10.
J Biomech ; 122: 110414, 2021 06 09.
Article in English | MEDLINE | ID: mdl-33915475

ABSTRACT

Spatiotemporal parameters can characterize the gait patterns of individuals, allowing assessment of their health status and detection of clinically meaningful changes in their gait. Video-based markerless motion capture is a user-friendly, inexpensive, and widely applicable technology that could reduce the barriers to measuring spatiotemporal gait parameters in clinical and more diverse settings. Two studies were performed to determine whether gait parameters measured using markerless motion capture demonstrate concurrent validity with those measured using marker-based motion capture and a pressure-sensitive gait mat. For the first study, thirty healthy young adults performed treadmill gait at self-selected speeds while marker-based motion capture and synchronized video data were recorded simultaneously. For the second study, twenty-five healthy young adults performed over-ground gait at self-selected speeds while footfalls were recorded using a gait mat and synchronized video data were recorded simultaneously. Kinematic heel-strike and toe-off gait events were used to identify the same gait cycles between systems. Nine spatiotemporal gait parameters were measured by each system and directly compared between systems. Measurements were compared using Bland-Altman methods, mean differences, Pearson correlation coefficients, and intraclass correlation coefficients. The results indicate that markerless measurements of spatiotemporal gait parameters have good to excellent agreement with marker-based motion capture and gait mat systems, except for stance time and double limb support time relative to both systems and stride width relative to the gait mat. These findings indicate that markerless motion capture can adequately measure spatiotemporal gait parameters of healthy young adults during treadmill and over-ground gait.


Subject(s)
Deep Learning , Algorithms , Biomechanical Phenomena , Gait , Humans , Reproducibility of Results , Walking , Young Adult
11.
J Arthroplasty ; 36(7): 2473-2479, 2021 07.
Article in English | MEDLINE | ID: mdl-33766448

ABSTRACT

BACKGROUND: There are numerous reports of poor satisfaction after total knee arthroplasty (TKA), yet there is little known about when to use evidence-based models of care to improve patient outcomes. OBJECTIVE: This study aimed to characterize longitudinal changes in patient-reported satisfaction after TKA and to identify factors for early identification of poor satisfaction. METHODS: For a cohort of primary TKA surgeries (n = 86), patient-reported outcomes were captured one week before TKA and 6 weeks, 12 weeks, 6 months, and 1 and 2 years after TKA. "Satisfied" versus "not fully satisfied" patients were defined using a binary response (≥90 vs <90) from a 100-point scale. Wilcoxon signed-rank tests identified changes in satisfaction between follow-up times, and longitudinal analyses examined demographic and questionnaire factors associated with satisfaction. RESULTS: Improvements in satisfaction occurred within the first 6 months after TKA (P ≤ 0.01). Preoperative patient-reported outcome measures alone were not predictive of satisfaction. Key factors that improved longitudinal satisfaction included higher Oxford Knee Scores (odds ratio (OR) = 2.1, P < .001), general health (EQ-VAS, OR = 1.3, P = .03), and less visual analog scale pain (VAS; OR = 1.7, P < .001). Differences in these factors between satisfied and not fully satisfied patients were identified as early as 6 weeks after surgery. CONCLUSION: Visibly different satisfaction profiles were captured among satisfied and not fully satisfied patient responses, with differences in patient-perceived joint function, general health, and pain severity occurring as early as 6 weeks after surgery. This study provides metrics to support early identification of patients at risk of poor TKA satisfaction, enabling clinicians to apply timely targeted treatment and support interventions, with the aim of improving patient outcomes.


Subject(s)
Arthroplasty, Replacement, Knee , Osteoarthritis, Knee , Humans , Knee Joint/surgery , Osteoarthritis, Knee/surgery , Patient Reported Outcome Measures , Patient Satisfaction , Quality of Life , Treatment Outcome
12.
J Arthroplasty ; 36(6): 2000-2005, 2021 06.
Article in English | MEDLINE | ID: mdl-33632580

ABSTRACT

BACKGROUND: High-viscosity (HV) bone cements have been formulated to offer potentially advantageous handling characteristics. However, alteration in the handling characteristics could influence implant fixation and survival. The primary objective of this study was to use radiostereometric analysis after total knee arthroplasty to assess the migration of the Triathlon tibial component fixed with HV cement (Simplex HV). METHODS: Twenty-three patients were followed for two years with radiostereometric analysis examinations at 6 visits. Migration was compared with published thresholds and with a control group from a previously published study from the same center using the same implants fixed with a medium viscosity cement. Inducible displacement was assessed, and Oxford 12 Knee Scores and satisfaction were recorded. RESULTS: Mean maximum total point motion migration reaching 0.40 mm (SD 0.16) at one year, and 0.41mm (SD 0.17) at two years, demonstrating a pattern of stable fixation, below published thresholds of acceptable migration, and not significantly different from the control group. One implant had continuous migration between 1 and 2 years but was clinically asymptomatic. Mean maximum total point motion inducible displacement measured at least one year postoperatively was 0.3 mm (SD 0.12). Mean Oxford 12 Knee Scores improved from 19 (SD 7) preoperatively to 42 (SD 8) 2 years postoperatively. CONCLUSIONS: The use of HV cement demonstrated an acceptable pattern of migration at 2 years, indicating low risk for aseptic loosening.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Bone Cements , Follow-Up Studies , Humans , Knee Joint/surgery , Osteoarthritis, Knee/surgery , Prosthesis Failure , Radiostereometric Analysis , Tibia/surgery , Viscosity
13.
Hip Int ; 31(2): 191-195, 2021 Mar.
Article in English | MEDLINE | ID: mdl-31615281

ABSTRACT

BACKGROUND: The long-term clinical success of cemented polished tapered femoral components has been demonstrated in prospective as well as registry studies. This stem design type has also been well studied with radiostereometric analysis (RSA) and provides a standard to evaluate alternative designs of polished tapered cemented femoral components. This prospective study evaluates the subsidence of a polished cemented stem with a modular neck design utilising RSA. METHODS: 26 patients were prospectively enrolled in the study and 23 were available for RSA analysis at 2 years. RESULTS: The average subsidence of the femoral implant was 1.1 mm (SD 0.4 mm) at 2 years post operation. There were no revisions in this group, specifically no failures of the modular stem-neck design as has been seen with other implants. CONCLUSIONS: The RSA subsidence pattern at 2 years of this cemented femoral stem is similar to other successful designs with long-term follow-up. The implications over time of stem neck modularity for cemented polished tapered femoral components requires further evaluation.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Arthroplasty, Replacement, Hip/adverse effects , Bone Cements , Follow-Up Studies , Humans , Prospective Studies , Prosthesis Design , Prosthesis Failure , Radiostereometric Analysis
14.
J Arthroplasty ; 35(4): 1109-1116, 2020 04.
Article in English | MEDLINE | ID: mdl-31866254

ABSTRACT

BACKGROUND: The anatomic dual mobility (ADM) acetabular component was introduced because of previously described low dislocation rates for this type of construct. The shape of the anatomic cup and the motion of polyethylene liner may have implications for acetabular cup fixation and polyethylene liner wear; therefore, the purpose of this study was to assess the migration patterns and wear rates of the ADM component using radiostereometric analysis. METHODS: Uncemented ADM acetabular components were implanted in 27 patients. Radiostereometric analysis exams were taken at 6 follow-up visits over 3 years. Proximal translation and sagittal rotation of the cup and polyethylene total wear and wear rates were calculated. Oxford 12 Hip scores and satisfaction were recorded. RESULTS: Mean proximal translation was below the 0.2 mm threshold at 2 years associated with acceptable long-term survivorship (0.16 mm [standard deviation {SD} 0.31] at 3 years). Mean sagittal rotation was 0.29 degrees (SD 1.03) and was greater in female subjects (P < .001). Following bedding-in, the annual wear rate was 0.02 mm/y, below the 0.1 mm/y threshold. There was no association between cup migration and polyethylene wear. Patient satisfaction at 3 years was 96%. Mean Oxford 12 Hip scores improved from 21 (SD 7) preoperatively to 43 (SD 7) 3 years postoperatively. CONCLUSIONS: The ADM cup demonstrated stable migration at 3 years indicating low risk for aseptic loosening. Bedding-in in the first year was followed by low annual wear rates. These finding suggest no increased risk of the dual mobility and anatomic design on fixation or wear.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Acetabulum/diagnostic imaging , Acetabulum/surgery , Arthroplasty, Replacement, Hip/adverse effects , Female , Follow-Up Studies , Humans , Polyethylene , Prosthesis Design , Prosthesis Failure , Radiostereometric Analysis
15.
Acta Orthop ; 90(2): 172-178, 2019 04.
Article in English | MEDLINE | ID: mdl-30669909

ABSTRACT

Background and purpose - Thresholds of implant migration for predicting long-term successful fixation of tibial components in total knee arthroplasty have not separated cemented and uncemented fixation. We compared implant migration of cemented and uncemented components at 1 year and as the change in migration from 1 to 2 years. Patients and methods - Implant migration of 360 tibial components measured using radiostereometric analysis was compared at 1 year and as the change in migration from 1 to 2 years in 222 cemented components (3 implant designs) and 138 uncemented components (5 implant designs). Results - 1-year maximum total point motion was lower for the cemented tibial components compared with the uncemented components (median = 0.31 mm [0.03-2.98] versus 0.63 mm [0.11-5.19] respectively, p < 0.001, mixed model). The change in migration from 1 to 2 years, however, was equivalent for cemented and uncemented components (mean [SD] 0.06 mm [0.19] and 0.07 mm [0.27] mm respectively, p = 0.6, mixed model). Interpretation - These findings suggest that current thresholds of acceptable migration at 1 year may be better optimized by considering cemented and uncemented tibial components separately as higher early migration of uncemented components was not associated with decreased stability from 1 to 2 years.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Joint , Knee Prosthesis , Osteoarthritis, Knee/surgery , Prosthesis Failure/etiology , Tibia/surgery , Aged , Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Knee/instrumentation , Arthroplasty, Replacement, Knee/methods , Bone Cements/therapeutic use , Female , Follow-Up Studies , Humans , Knee Joint/pathology , Knee Joint/surgery , Knee Prosthesis/adverse effects , Knee Prosthesis/statistics & numerical data , Male , Middle Aged , Prosthesis Design , Radiostereometric Analysis/methods , Time , Time Factors , Treatment Outcome
16.
J Pediatr Orthop B ; 27(6): 496-502, 2018 Nov.
Article in English | MEDLINE | ID: mdl-29762188

ABSTRACT

Physeal closure after slipped capital femoral epiphysis fixation can be difficult to assess on two-dimensional conventional radiographs. Radiostereometric analysis offers improved motion detection over conventional radiography, whereas the EOS biplanar imager provides a means for low radiation weight-bearing images. This phantom study assessed the reliability of measuring motion using radiostereometric analysis in the EOS using a slipped capital femoral epiphysis model. The accuracy and precision were better than 0.09±0.05 mm and 0.20°±0.36° when centered in the imaging space, were within the limits of clinical significance, and were not different from a standard uniplanar radiostereometric system.


Subject(s)
Growth Plate/diagnostic imaging , Phantoms, Imaging/standards , Radiostereometric Analysis/standards , Slipped Capital Femoral Epiphyses/diagnostic imaging , Humans , Radiostereometric Analysis/methods , Reproducibility of Results
17.
J Biomech ; 42(14): 2387-93, 2009 Oct 16.
Article in English | MEDLINE | ID: mdl-19660755

ABSTRACT

An in vitro radiostereometric analysis (RSA) phantom study of a total knee replacement was carried out to evaluate the effect of implementing two new modifications to the conventional RSA procedure: (i) adding a landmark of the tibial component as an implant marker and (ii) defining an implant-based coordinate system constructed from implant landmarks for the calculation of migration results. The motivation for these two modifications were (i) to improve the representation of the implant by the markers by including the stem tip marker which increases the marker distribution (ii) to recover clinical RSA study cases with insufficient numbers of markers visible in the implant polyethylene and (iii) to eliminate errors in migration calculations due to misalignment of the anatomical axes with the RSA global coordinate system. The translational and rotational phantom studies showed no loss of accuracy with the two new measurement methods. The RSA system employing these methods has a precision of better than 0.05 mm for translations and 0.03 degrees for rotations, and an accuracy of 0.05 mm for translations and 0.15 degrees for rotations. These results indicate that the new methods to improve the interpretability, relevance, and standardization of the results do not compromise precision and accuracy, and are suitable for application to clinical data.


Subject(s)
Arthrography/methods , Arthroplasty, Replacement, Knee/methods , Imaging, Three-Dimensional/methods , Knee Joint/diagnostic imaging , Knee Joint/surgery , Radiographic Image Interpretation, Computer-Assisted/methods , Surgery, Computer-Assisted/methods , Humans , Motion , Phantoms, Imaging , Reproducibility of Results , Sensitivity and Specificity