ABSTRACT

A new temperature performance record of 199.5 K for terahertz quantum cascade lasers is achieved by optimizing the lasing transition oscillator strength of the resonant phonon based three-well design. The optimum oscillator strength of 0.58 was found to be larger than that of the previous record (0.41) by Kumar et al. [Appl. Phys. Lett. 94, 131105 (2009)]. The choice of tunneling barrier thicknesses was determined with a simplified density matrix model, which converged towards higher tunneling coupling strengths than previously explored and nearly perfect alignment of the states across the injection and extraction barriers at the design electric field. At 8 K, the device showed a threshold current density of 1 kA/cm2, with a peak output power of ∼ 38 mW, and lasing frequency blue-shifting from 2.6 THz to 2.85 THz with increasing bias. The wavelength blue-shifted to 3.22 THz closer to the maximum operating temperature of 199.5 K, which corresponds to ∼ 1.28hω/κB. The voltage dependence of laser frequency is related to the Stark effect of two intersubband transitions and is compared with the simulated gain spectra obtained by a Monte Carlo approach.

2.
Opt Express ; 18(10): 10036-48, 2010 May 10.
Article in English | MEDLINE | ID: mdl-20588857

ABSTRACT

The design and fabrication of a high power THz quantum cascade laser (QCL), with electrically controllable transverse mode is presented. The switching of the beam pattern results in dynamic beam switching using a symmetric side current injection scheme. The angular-resolved L-I curves measurements, near-field and far-field patterns and angular-resolved lasing spectra are presented. The measurement results confirm that the quasi-TM(01) transverse mode lases first and dominates the lasing operation at lower current injection, while the quasi-TM(00) mode lases at a higher threshold current density and becomes dominant at high current injection. The near-field and far-field measurements confirm that the lasing THz beam is maneuvered by 25 degrees in emission angle, when the current density changes from 1.9 kA/cm(2) to 2.3 kA/cm(2). A two-dimension (2D) current and mode calculation provides a simple model to explain the behavior of each mode under different bias conditions.


Subject(s)
Lasers , Signal Processing, Computer-Assisted/instrumentation , Computer-Aided Design , Equipment Design , Equipment Failure Analysis , Reproducibility of Results , Sensitivity and Specificity , Terahertz Radiation
SELECTION OF CITATIONS
SEARCH DETAIL
...