1.
Front Oncol ; 12: 882476, 2022.
Article in English | MEDLINE | ID: mdl-35692801

ABSTRACT

The aim of this work is to present a reproducible methodology for the evaluation of total equivalent doses in organs during proton therapy facilities. The methodology is based on measuring the dose equivalent in representative locations inside an anthropomorphic phantom where photon and neutron dosimeters were inserted. The Monte Carlo simulation was needed for obtaining neutron energy distribution inside the phantom. The methodology was implemented for a head irradiation case in the passive proton beam of iThemba Labs (South Africa). Thermoluminescent dosimeter (TLD)-600 and TLD-700 pairs were used as dosimeters inside the phantom and GEANT code for simulations. In addition, Bonner sphere spectrometry was performed inside the treatment room to obtain the neutron spectra, some relevant neutron dosimetric quantities per treatment Gy, and a percentual distribution of neutron fluence and ambient dose equivalent in four energy groups, at two locations. The neutron spectrum at one of those locations was also simulated so that a reasonable agreement between simulation and measurement allowed a validation of the simulation. Results showed that the total out-of-field dose equivalent inside the phantom ranged from 1.4 to 0.28 mSv/Gy, mainly due to the neutron contribution and with a small contribution from photons, 10% on average. The order of magnitude of the equivalent dose in organs was similar, displaying a slow reduction in values as the organ is farther from the target volume. These values were in agreement with those found by other authors in other passive beam facilities under similar irradiation and measurement conditions.

2.
Phys Med Biol ; 63(3): 035007, 2018 01 25.
Article in English | MEDLINE | ID: mdl-29256451

ABSTRACT

We have verified the GAMOS/Geant4 simulation model of a 6 MV VARIAN Clinac 2100 C/D linear accelerator by the procedure of adjusting the initial beam parameters to fit the percentage depth dose and cross-profile dose experimental data at different depths in a water phantom. Thanks to the use of a wide range of field sizes, from 2 × 2 cm2 to 40 × 40 cm2, a small phantom voxel size and high statistics, fine precision in the determination of the beam parameters has been achieved. This precision has allowed us to make a thorough study of the different physics models and parameters that Geant4 offers. The three Geant4 electromagnetic physics sets of models, i.e. Standard, Livermore and Penelope, have been compared to the experiment, testing the four different models of angular bremsstrahlung distributions as well as the three available multiple-scattering models, and optimizing the most relevant Geant4 electromagnetic physics parameters. Before the fitting, a comprehensive CPU time optimization has been done, using several of the Geant4 efficiency improvement techniques plus a few more developed in GAMOS.


Subject(s)
Computer Simulation , Gamma Rays , Monte Carlo Method , Particle Accelerators/instrumentation , Particle Accelerators/standards , Phantoms, Imaging , Radiotherapy Planning, Computer-Assisted/methods , Humans , Radiometry/methods , Radiotherapy Dosage
3.
Appl Radiat Isot ; 78: 10-5, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23587860

ABSTRACT

Nowadays the demand and the installation of self-shielded low-energy cyclotrons is growing, allowing the use of (11)C in many more centers. The aim of this study was the design of a new target and the evaluation of the production of (11)C as [(11)C]CO2 at low proton energies. The target was coupled to an IBA Cyclone-18/9 and the energy was decreased to 4-16 MeV. The newly designed target allowed the production of [(11)C]CO2 at different proton energies, and the results suggest that the cyclotron energy of Cyclone-18/9 is slightly higher than the nominal 18 MeV.


Subject(s)
Carbon Dioxide/chemical synthesis , Carbon Dioxide/isolation & purification , Carbon Isotopes/chemical synthesis , Carbon Isotopes/isolation & purification , Carbon Dioxide/radiation effects , Carbon Isotopes/radiation effects , Energy Transfer , Gases/chemical synthesis , Gases/isolation & purification , Gases/radiation effects , Isotope Labeling/methods , Protons
4.
Radiother Oncol ; 102(1): 135-41, 2012 Jan.
Article in English | MEDLINE | ID: mdl-21737167

ABSTRACT

BACKGROUND AND PURPOSE: Small radiation beams (<4 cm width) are being increasingly used in the delivery of advanced techniques as Intensity Modulated Radiotherapy (IMRT) and Stereotactic Radiosurgery (SRS). Dose measurements in small beams present challenges not encountered for larger beams. A postal audit with Thermoluminiscent Dosimeters (TLD) was developed to check the doses in small photon beams. A validation test in real conditions was carried out in fourteen centres. MATERIAL AND METHODS: The TLD postal audit employs very small chips (1×1×1 mm(3)) of TLD-100 inserted at 5 and 10 cm of depth in a cylindrical PMMA phantom designed for this purpose. This experimental system is mailed to the audited centres to be irradiated with beams of 1 and 3 cm of side or diameter. The prescribeddose is 1.5 Gy at 10 cm. The properties of this system were studied experimentally and by Monte Carlo (MC) simulation, before the external test. RESULTS: Deviations between the prescribed and measured absorbed doses are below 5% for 69% (1×1 cm(2) beam) and 64% (3×3 cm(2) beam) of the audited centres. When deviations are above 5%, their causes have been investigated and led to corrections. CONCLUSION: The developed postal audit is suitable to verify the absorbed doses in small photon beams with an accuracy of 2.9% (1 s).


Subject(s)
Medical Audit , Postal Service , Radiotherapy/standards , Thermoluminescent Dosimetry , Humans , Monte Carlo Method , Phantoms, Imaging , Photons , Radiometry , Radiotherapy Dosage , Reproducibility of Results , Spain
5.
Int J Radiat Oncol Biol Phys ; 68(1): 301-10, 2007 May 01.
Article in English | MEDLINE | ID: mdl-17448883

ABSTRACT

PURPOSE: Intensity-modulated radiotherapy (IMRT) represents an important method for improving RT. The IMRT relative dosimetry checks are well established; however, open questions remain in reference dosimetry with ionization chambers (ICs). The main problem is the departure of the measurement conditions from the reference ones; thus, additional uncertainty is introduced into the dose determination. The goal of this study was to assess this effect systematically. METHODS AND MATERIALS: Monte Carlo calculations and dosimetric measurements with five different detectors were performed for a number of representative IMRT cases, covering both step-and-shoot and dynamic delivery. RESULTS: Using ICs with volumes of about 0.125 cm(3) or less, good agreement was observed among the detectors in most of the situations studied. These results also agreed well with the Monte Carlo-calculated nonreference correction factors (c factors). Additionally, we found a general correlation between the IC position relative to a segment and the derived correction factor c, which can be used to estimate the expected overall uncertainty of the treatment. CONCLUSION: The increase of the reference dose relative standard uncertainty measured with ICs introduced by nonreference conditions when verifying an entire IMRT plan is about 1-1.5%, provided that appropriate small-volume chambers are used. The overall standard uncertainty of the measured IMRT dose amounts to about 2.3%, including the 0.5% of reproducibility and 1.5% of uncertainty associated with the beam calibration factor. Solid state detectors and large-volume chambers are not well suited to IMRT verification dosimetry because of the greater uncertainties. An action level of 5% is appropriate for IMRT verification. Greater discrepancies should lead to a review of the dosimetric procedure, including visual inspection of treatment segments and energy fluence.


Subject(s)
Radiotherapy Dosage/standards , Radiotherapy, Intensity-Modulated/standards , Calibration , Monte Carlo Method , Quality Control , Radiometry/instrumentation , Radiometry/standards , Reference Values , Uncertainty
6.
Med Phys ; 31(9): 2416-22, 2004 Sep.
Article in English | MEDLINE | ID: mdl-15487721

ABSTRACT

Intensity modulated radiation therapy (IMRT) has evolved toward the use of many small radiation fields, or "beamlets," to increase the resolution of the intensity map. The size of smaller beamlets can be typically about 1-5 cm2. Therefore small ionization chambers (IC) with sensitive volumes < or = 0.1 cm3 are generally used for dose verification of IMRT treatment. The dosimetry of these narrow photon beams pertains to the so-called nonreference conditions for beam calibration. The use of ion chambers for such narrow beams remains questionable due to the lack of electron equilibrium in most of the field. The present contribution aims to estimate, by the Monte Carlo (MC) method, the total correction needed to convert the IBA-Wellhöfer NAC007 micro IC measured charge in such radiation field to the absolute dose to water. Detailed geometrical simulation of the microionization chamber was performed. The ion chamber was always positioned at a 10 cm depth in water, parallel to the beam axis. The delivered doses to air and water cavity were calculated using the CAVRZ EGSnrc user code. The 6 MV phase-spaces for Primus Clinac (Siemens) used as an input to the CAVRZnrc code were derived by BEAM/EGS4 modeling of the treatment head of the machine along with the multileaf collimator [Sánchez-Doblado et al., Phys. Med. Biol. 48, 2081-2099 (2003)] and contrasted with experimental measurements. Dose calculations were carried out for two irradiation geometries, namely, the reference 10x10 cm2 field and an irregular (approximately 2x2 cm2) IMRT beamlet. The dose measured by the ion chamber is estimated by MC simulation as a dose averaged over the air cavity inside the ion-chamber (Dair). The absorbed dose to water is derived as the dose deposited inside the same volume, in the same geometrical position, filled and surrounded by water (Dwater) in the absence of the ionization chamber. Therefore, the Dwater/Dair dose ratio is a MC direct estimation of the total correction factor needed to convert the absorbed dose in air to absorbed dose to water. The dose ratio was calculated for several chamber positions, starting from the penumbra region around the beamlet along the two diagonals crossing the radiation field. For this quantity from 0 up to a 3% difference is observed between the dose ratio values obtained within the small irregular IMRT beamlet in comparison with the dose ratio derived for the reference 10x10 cm2 field. Greater differences from the reference value up to 9% were obtained in the penumbra region of the small IMRT beamlet.


Subject(s)
Algorithms , Models, Statistical , Monte Carlo Method , Radiometry/instrumentation , Radiometry/methods , Radiotherapy, Conformal/instrumentation , Radiotherapy, Conformal/methods , Computer Simulation , Equipment Failure Analysis/methods , Radiometry/standards , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/instrumentation , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy Planning, Computer-Assisted/standards , Radiotherapy, Conformal/standards , Reproducibility of Results , Sensitivity and Specificity
7.
Int J Radiat Oncol Biol Phys ; 59(5): 1548-59, 2004 Aug 01.
Article in English | MEDLINE | ID: mdl-15275743

ABSTRACT

PURPOSE: The influence of the multileaf collimator (MLC) leaf width on the dose distribution in patients treated with conformal radiotherapy and intensity-modulated radiotherapy has been analyzed. This study was based on the Monte Carlo simulation with the beams generated by a linac with the double-focused MLC. MATERIALS AND METHODS: The transmission through the leaves and the exact shape of the penumbra regions are difficult to model by treatment planning system algorithms. An accurate assessment of the dose variations due to the leaf width change can be achieved by means of Monte Carlo simulation. The BEAM/EGS4 code was used at the Hospital of the Virgen Macarena to model a Siemens PRIMUS linac, featuring an MLC with a leaf width projecting 1 cm at the isocenter. Based on this real model, a virtual head was designed while allowing for a variation of the leaf width projection. Both the real linac and the virtual linac, with leaves projecting 0.5 cm, were used to obtain the dose distributions for several treatments. A few disease sites, including the prostate, head and neck, and endometrium, were selected for the design of the conformal and intensity-modulated radiotherapy treatments with a forward planning algorithm sensitive to the different shapes of the volumes of interest. Isodose curves, differential matrix, gamma function, and the dose-volume histograms (DVHs) corresponding to both MLC models were obtained for all cases. The tumor control probability and the normal tissue complication probability were derived for those cases studied featuring the greatest differences between results for both MLCs. RESULTS: The impact on the DVHs of changing leaf width projections at the isocenter from 1.0 cm to 0.5 cm was low. Radiobiologic models showed slightly better tumor control probability/normal tissue complication probability values using the virtual MLC with a leaf width projecting 0.5 cm at isocenter in those cases presenting greater differences in the DVHs. CONCLUSIONS: The impact on the clinical dose distribution due to the MLC leaf width change is low based on the design and conditions used in this study.


Subject(s)
Monte Carlo Method , Neoplasms/radiotherapy , Radiotherapy, Conformal/instrumentation , Abdominal Neoplasms/radiotherapy , Endometrial Neoplasms/radiotherapy , Equipment Design , Female , Head and Neck Neoplasms/radiotherapy , Humans , Male , Models, Biological , Phantoms, Imaging , Prostatic Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods
8.
Phys Med Biol ; 48(17): 2783-96, 2003 Sep 07.
Article in English | MEDLINE | ID: mdl-14516101

ABSTRACT

Total skin electron therapy (TSET) is a complex technique which requires non-standard measurements and dosimetric procedures. This paper investigates an essential first step towards TSET Monte Carlo (MC) verification. The non-standard 6 MeV 40 x 40 cm2 electron beam at a source to surface distance (SSD) of 100 cm as well as its horizontal projection behind a polymethylmethacrylate (PMMA) screen to SSD = 380 cm were evaluated. The EGS4 OMEGA-BEAM code package running on a Linux home made 47 PCs cluster was used for the MC simulations. Percentage depth-dose curves and profiles were calculated and measured experimentally for the 40 x 40 cm2 field at both SSD = 100 cm and patient surface SSD = 380 cm. The output factor (OF) between the reference 40 x 40 cm2 open field and its horizontal projection as TSET beam at SSD = 380 cm was also measured for comparison with MC results. The accuracy of the simulated beam was validated by the good agreement to within 2% between measured relative dose distributions, including the beam characteristic parameters (R50, R80, R100, Rp, E0) and the MC calculated results. The energy spectrum, fluence and angular distribution at different stages of the beam (at SSD = 100 cm, at SSD = 364.2 cm, behind the PMMA beam spoiler screen and at treatment surface SSD = 380 cm) were derived from MC simulations. Results showed a final decrease in mean energy of almost 56% from the exit window to the treatment surface. A broader angular distribution (FWHM of the angular distribution increased from 13 degrees at SSD = 100 cm to more than 30 degrees at the treatment surface) was fully attributable to the PMMA beam spoiler screen. OF calculations and measurements agreed to less than 1%. The effect of changing the electron energy cut-off from 0.7 MeV to 0.521 MeV and air density fluctuations in the bunker which could affect the MC results were shown to have a negligible impact on the beam fluence distributions. Results proved the applicability of using MC as a treatment verification tool for complex radiotherapy techniques.


Subject(s)
Electrons/therapeutic use , Models, Biological , Monte Carlo Method , Mycosis Fungoides/radiotherapy , Radiometry/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Conformal/methods , Skin Neoplasms/radiotherapy , Computer Simulation , Humans , Models, Statistical , Phantoms, Imaging , Radiotherapy Dosage , Reproducibility of Results , Sensitivity and Specificity
9.
Int J Radiat Oncol Biol Phys ; 56(1): 58-68, 2003 May 01.
Article in English | MEDLINE | ID: mdl-12694824

ABSTRACT

PURPOSE: A tool to simulate complete intensity-modulated radiation therapy (IMRT) treatments with the Monte Carlo (MC) method has been developed. This application is based on a distribution model to employ as short processing times as possible for an operative verification. MATERIALS AND METHODS: The Clinical Primus-Siemens Linac beam was simulated with MC, using the EGS4 OMEGA-BEAM code package. An additional home-made program prepares the appropriate parameters for the code, using as input the file sent from the planning system to the linac. These parameters are adapted to the simulation code, making physical and clinical subdivisions of the global simulation of the treatment. Each resultant partition is ordered to a client personal computer in a cluster with 47 machines under a Linux environment. The verification procedure starts delivering the treatment on a plastic phantom containing an ionization chamber. If differences are less than 2%, films are inserted at selected planes in the phantom and the treatment is delivered again to evaluate the relative doses. When matching between treatment planning system (TPS), film, and MC is acceptable, a new evaluation of the patient is then performed between TPS and MC. Three different cases are shown to prove the applicability of the verification model. RESULTS: Acceptable agreement between the three methods used was obtained. The results are presented using different analysis tools. The actual time employed to simulate the total treatment in each case was no more than 5 h, depending on the number of segments. CONCLUSIONS: The MC model presented is fully automated, and results can be achieved within the operative time limits. The procedure is a reliable tool to verify any IMRT treatment.


Subject(s)
Computer Simulation , Monte Carlo Method , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Conformal/methods , Adenocarcinoma/radiotherapy , Automation , Brain Neoplasms/radiotherapy , Calibration , Humans , Male , Particle Accelerators , Phantoms, Imaging , Prostatic Neoplasms/radiotherapy , Radiometry , Radiotherapy, Conformal/standards , Septum Pellucidum , Software