Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 115
Filter
1.
JACC Case Rep ; 29(8): 102278, 2024 Apr 17.
Article in English | MEDLINE | ID: mdl-38774795

ABSTRACT

Implantation of prosthetic heart valves may result in both early and late complications. Early complications are usually structural and can have significant hemodynamic consequences. In this clinical vignette, we highlight how malposition of a newly implanted aortic valve resulted in alterations of coronary perfusion pressure physiology and subsequent significant hemodynamic effects.

3.
Am J Cardiol ; 214: 1-7, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38110018

ABSTRACT

Transcatheter aortic valve replacement (TAVR) provides an option for extreme-risk patients who underwent reoperation for a failed surgical aortic bioprosthesis. Long-term data on patients who underwent TAVR within a failed surgical aortic valve (TAV-in-SAV) are limited. The CoreValve Expanded Use Study evaluated patients at extreme surgical risk who underwent TAV-in-SAV. Outcomes at 5 years were analyzed by SAV failure mode (stenosis, regurgitation, or combined). Echocardiographic outcomes are site-reported. TAV-in-SAV was attempted in 226 patients with a mean age of 76.7 ± 10.8 years; 63.3% were male, the Society of Thoracic Surgeons predicted risk of mortality score was 9.0 ± 6.7%, and 87.5% had a New York Heart Association classification III or IV symptoms. Most of the failed surgical bioprostheses were stented (81.9%), with an average implant duration of 10.2 ± 4.3 years. The 5-year all-cause mortality or major stroke rate was 47.2% in all patients; 54.4% in the stenosis, 37.6% in the regurgitation, and 38.0% in the combined groups (p = 0.046). At 5 years, all-cause mortality was higher in patients with versus without 30-day severe prosthesis-patient mismatch (51.7% vs 38.3%, p = 0.026). The overall aortic valve reintervention rate was 5.9%; highest in the regurgitation group (12.6%). The mean aortic valve gradient was 14.1 ± 9.8 mm Hg and effective orifice area was 1.57 ± 0.70 at 5 years. Few patients had >mild paravalvular regurgitation at 5 years (5.5% moderate, 0.0% severe). TAV-in-SAV with supra-annular, self-expanding TAVR continues to represent a safe and lasting intermediate option for extreme-risk patients who have appropriate sizing of the preexisting failed surgical valve. Clinical and hemodynamic outcomes were stable through 5 years.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Male , Aged , Aged, 80 and over , Female , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Follow-Up Studies , Constriction, Pathologic/etiology , Constriction, Pathologic/surgery , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/etiology , Treatment Outcome , Transcatheter Aortic Valve Replacement/adverse effects , Surgical Instruments , Prosthesis Design , Risk Factors
4.
Article in English | MEDLINE | ID: mdl-37962288

ABSTRACT

BACKGROUND: The CLASP IID (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical) trial is the first randomized controlled trial comparing the PASCAL system and the MitraClip system in prohibitive risk patients with significant symptomatic degenerative mitral regurgitation (DMR). OBJECTIVES: The study sought to report primary and secondary endpoints and 1-year outcomes for the full cohort of the CLASP IID trial. METHODS: Prohibitive-risk patients with 3+/4+ DMR were randomized 2:1 (PASCAL:MitraClip). One-year assessments included secondary effectiveness endpoints (mitral regurgitation [MR] ≤2+ and MR ≤1+), and clinical, echocardiographic, functional, and quality-of-life outcomes. Primary safety (30-day composite major adverse events [MAE]) and effectiveness (6-month MR ≤2+) endpoints were assessed for the full cohort. RESULTS: Three hundred patients were randomized (PASCAL: n = 204; MitraClip: n = 96). At 1 year, differences in survival, freedom from heart failure hospitalization, and MAE were nonsignificant (P > 0.05 for all). Noninferiority of the PASCAL system compared with the MitraClip system persisted for the primary endpoints in the full cohort (For PASCAL vs MitraClip, the 30-day MAE rates were 4.6% vs 5.4% with a rate difference of -0.8% and 95% upper confidence bound of 4.6%. The 6-month MR≤2+ rates were 97.9% vs 95.7% with a rate difference of 2.2% and 95% lower confidence bound (LCB) of -2.5%, for, respectively). Noninferiority was met for the secondary effectiveness endpoints at 1 year (MR≤2+ rates for PASCAL vs MitraClip were 95.8% vs 93.8% with a rate difference of 2.1% and 95% LCB of -4.1%. The MR≤1+ rates were 77.1% vs 71.3% with a rate difference of 5.8% and 95% LCB of -5.3%, respectively). Significant improvements in functional classification and quality of life were sustained in both groups (P <0.05 for all vs baseline). CONCLUSIONS: The CLASP IID trial full cohort met primary and secondary noninferiority endpoints, and at 1 year, the PASCAL system demonstrated high survival, significant MR reduction, and sustained improvements in functional and quality-of-life outcomes. Results affirm the PASCAL system as a beneficial therapy for prohibitive-surgical-risk patients with significant symptomatic DMR.

5.
JACC Cardiovasc Interv ; 16(23): 2820-2832, 2023 Dec 11.
Article in English | MEDLINE | ID: mdl-37905772

ABSTRACT

BACKGROUND: Favorable 6-month outcomes from the CLASP IID Registry (Edwards PASCAL transcatheter valve repair system pivotal clinical trial) demonstrated that mitral valve transcatheter edge-to-edge repair with the PASCAL transcatheter valve repair system is safe and beneficial for treating prohibitive surgical risk degenerative mitral regurgitation (DMR) patients with complex mitral valve anatomy. OBJECTIVES: The authors sought to assess 1-year safety, echocardiographic and clinical outcomes from the CLASP IID Registry. METHODS: Patients with 3+ or 4+ DMR who were at prohibitive surgical risk, had complex mitral valve anatomy based on the MitraClip Instructions for Use, and deemed suitable for treatment with the PASCAL system were enrolled prospectively. Safety, clinical, echocardiographic, functional, and quality-of-life outcomes were assessed at 1 year. Study oversight included a central screening committee, echocardiographic core laboratory, and clinical events committee. RESULTS: Ninety-eight patients were enrolled. One-year Kaplan-Meier (KM) estimates of freedom from composite major adverse events, all-cause mortality, and heart failure hospitalization were 83.5%, 89.3%, and 91.5%, respectively. Significant mitral regurgitation (MR) reduction was achieved at 1 year (P < 0.001 vs baseline) including 93.2% at MR ≤2+ and 57.6% at MR ≤1+ with improvements in related echocardiographic measures. NYHA functional class and Kansas City Cardiomyopathy Questionnaire score also improved significantly (P < 0.001 vs baseline). CONCLUSIONS: At 1 year, treatment with the PASCAL system demonstrated safety and significant MR reduction, with continued improvement in clinical, echocardiographic, functional, and quality-of-life outcomes, illustrating the value of the PASCAL system in the treatment of prohibitive surgical risk patients with 3+ or 4+ DMR and complex mitral valve anatomy.


Subject(s)
Cardiac Catheterization , Mitral Valve Insufficiency , Humans , Cardiac Catheterization/adverse effects , Echocardiography , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Treatment Outcome , Clinical Trials as Topic
6.
Am J Cardiol ; 208: 37-43, 2023 12 01.
Article in English | MEDLINE | ID: mdl-37812864

ABSTRACT

Optimal timing for aortic valve replacement in symptomatic patients with less than severe aortic stenosis (AS) is not well defined. There is limited information on the benefit of valve replacement in these patients. Symptomatic patients with less than severe AS, defined as a mean aortic gradient ≥20 and <40 mm Hg, peak aortic velocity >3 and <4 m/s, and aortic valve area >1.0 and <1.5 cm2, enrolled in the Society for Thoracic Surgery/American College of Cardiology Transcatheter Valve Therapy Registry and who underwent attempted supra-annular, self-expanding transcatheter aortic valve replacement (TAVR) were reviewed. Site-reported valve hemodynamics, clinical events, and quality of life metrics were analyzed at 30 days and 1 year after the procedure. A total of 1,067 patients with attempted TAVR (mean age 78.4 ± 8.4 years; Society for Thoracic Surgery score 4.7 ± 3.4%) were found to have symptoms but less than severe AS. From baseline to postprocedure, mean gradient decreased (29.9 ± 4.9 vs 8.4 ± 4.8 mm Hg, p <0.001), and aortic valve area increased (1.2 ± 0.1 vs 2.2 ± 0.7 cm2, p <0.001). Clinical events included 30-day and 1-year all-cause mortality (1.5% and 9.6%), stroke (2.2% and 3.3%), and new pacemaker implantation (18.1% and 20.9%). There were statistically significant improvements in the New York Heart Association functional class and Kansas City Cardiomyopathy Questionnaire at 30 days and 1 year. In conclusion, patients with symptomatic but less than severe AS who underwent supra-annular, self-expanding TAVR experienced improved valve hemodynamics and quality of life measures 1 year after the procedure. Randomized studies of TAVR versus a control arm in symptomatic patients with less than severe AS are ongoing.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aged , Aged, 80 and over , Transcatheter Aortic Valve Replacement/adverse effects , Quality of Life , Treatment Outcome , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Echocardiography , Risk Factors
8.
J Cardiothorac Vasc Anesth ; 37(11): 2194-2203, 2023 11.
Article in English | MEDLINE | ID: mdl-37316432

ABSTRACT

Transcatheter edge-to-edge repair (TEER) of the mitral valve is a complex procedure requiring continuous image guidance with 2-dimensional and 3-dimensional transesophageal echocardiography. In this context, the role of the echocardiographer is of paramount importance. Training in interventional echocardiography for procedures such as TEER requires comprehending the complicated workflow of the hybrid operating room and advanced imaging skills that go beyond traditional echocardiography training to guide the procedure. Despite TEER being more commonly performed, the training structure for interventional echocardiographers is lagging, with many practitioners not having any formal training in image guidance for this procedure. In this context, novel training strategies must be developed to increase exposure and aid training. In this review, the authors present a step-wise approach to training for image guidance during TEER of the mitral valve. The authors have deconstructed this complex procedure into modular components and have incremental stages of training based on different steps of the procedure. At each step, trainees must demonstrate proficiency before advancing to the next step, thus ensuring a more structured approach to attaining proficiency in this complex procedure.


Subject(s)
Cardiac Surgical Procedures , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Cardiac Catheterization/methods , Echocardiography , Heart Valve Prosthesis Implantation/methods , Treatment Outcome
9.
Open Heart ; 10(1)2023 05.
Article in English | MEDLINE | ID: mdl-37173100

ABSTRACT

OBJECTIVE: To evaluate whether transcatheter or surgical aortic valve replacement (TAVR or SAVR) affects clinical and haemodynamic outcomes in symptomatic patients with moderately-severe aortic stenosis (AS). METHODS: Echocardiographic evidence of severe AS for enrolment in the Evolut Low Risk trial was based on site-reported measurements. For this post hoc analysis, core laboratory measurements identified patients with symptomatic moderately-severe AS (1.0

Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/adverse effects , Quality of Life , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/etiology , Treatment Outcome
10.
J Am Coll Cardiol ; 81(5): 431-442, 2023 02 07.
Article in English | MEDLINE | ID: mdl-36725171

ABSTRACT

BACKGROUND: Mitral valve transcatheter edge-to-edge repair is safe and effective in treating degenerative mitral regurgitation (DMR) patients at prohibitive surgical risk, but outcomes in complex mitral valve anatomy patients vary. OBJECTIVES: The PASCAL IID registry assessed safety, echocardiographic, and clinical outcomes with the PASCAL system in prohibitive risk patients with significant symptomatic DMR and complex mitral valve anatomy. METHODS: Patients in the prospective, multicenter, single-arm registry had 3+ or 4+ DMR, were at prohibitive surgical risk, presented with complex anatomic features based on the MitraClip instructions for use, and were deemed suitable for the PASCAL system by a central screening committee. Enrolled patients were treated with the PASCAL system. Safety, effectiveness, and functional and quality-of-life outcomes were assessed. Study oversight also included an echocardiographic core laboratory and clinical events committee. RESULTS: The study enrolled 98 patients (37.2% ≥2 independent significant jets, 15.0% severe bileaflet/multi scallop prolapse, 13.3% mitral valve orifice area <4.0 cm2, and 10.6% large flail gap and/or large flail width). The implant success rate was 92.9%. The 30-day composite major adverse event rate was 11.2%. At 6 months, 92.4% patients achieved MR ≤2+ and 56.1% achieved MR ≤1+ (P < 0.001 vs baseline). The Kaplan-Meier estimates for survival, freedom from major adverse events, and heart failure hospitalization at 6 months were 93.7%, 85.6%, and 92.6%, respectively. Patients experienced significant symptomatic improvement compared with baseline (P < 0.001). CONCLUSIONS: The outcomes of the PASCAL IID registry establish the PASCAL system as a useful therapy for prohibitive surgical risk DMR patients with complex mitral valve anatomy. (PASCAL IID Registry within the Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial [CLASP IID] NCT03706833).


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Prospective Studies , Treatment Outcome , Heart Valve Prosthesis Implantation/adverse effects , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Cardiac Catheterization/adverse effects
11.
Cardiovasc Revasc Med ; 47: 48-54, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36266154

ABSTRACT

We evaluated predictors of permanent pacemaker implantation (PPI) following self-expanding transcatheter aortic valve replacement (TAVR), examined site-to-site variability of PPI rates, and explored the relationship of implantation methods on the need for PPI. Despite the benefits of TAVR compared to surgical aortic valve replacement, increased PPI remains a limitation. A total of 699 patients without baseline PPI were included in the study. Clinical, echocardiographic, and procedural characteristics were compared in patient with and without new PPI. Clinical outcomes were assessed at 30 days and 1 year. Funnel plots were constructed to display site-to- site variability and identify outliers in PPI. Clinical outcomes were similar in patients with and without PPI. Predictors of a new PPI within 7 days included a baseline right bundle branch block (p < 0.001) and not using general anesthesia (p = 0.003). There was substantial site to site variability in the rate of PPI. Patients at sites with a lower PPI rate had shallower implantation depth at the non-coronary (p < 0.001) and the left coronary sinus (p < 0.001), and fewer patients with an implantation depth > 5 mm below the annulus (p = 0.004). In low-risk patients undergoing TAVR with Evolut valves, baseline conduction disorders and implant depth were important predictors of PPI. Implantation method may have contributed to this variability in PPI rates across clinical sites.


Subject(s)
Aortic Valve Stenosis , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis , Pacemaker, Artificial/statistics & numerical data , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
12.
JACC Cardiovasc Interv ; 15(24): 2523-2536, 2022 12 26.
Article in English | MEDLINE | ID: mdl-36121247

ABSTRACT

BACKGROUND: Severe symptomatic degenerative mitral regurgitation (DMR) has a poor prognosis in the absence of treatment, and new transcatheter options are emerging. OBJECTIVES: The CLASP IID (Edwards PASCAL Transcatheter Valve Repair System Pivotal Clinical Trial) randomized trial (NCT03706833) is the first to evaluate the safety and effectiveness of the PASCAL system compared with the MitraClip system in patients with significant symptomatic DMR. This report presents the primary safety and effectiveness endpoints for the trial. METHODS: Patients with 3+ or 4+ DMR at prohibitive surgical risk were assessed by a central screening committee and randomized 2:1 (PASCAL:MitraClip). Study oversight also included an echocardiography core laboratory and a clinical events committee. The primary safety endpoint was the composite major adverse event rate at 30 days. The primary effectiveness endpoint was the proportion of patients with mitral regurgitation (MR) ≤2+ at 6 months. RESULTS: A prespecified interim analysis in 180 patients demonstrated noninferiority of the PASCAL system vs the MitraClip system for the primary safety and effectiveness endpoints of major adverse event rate (3.4% vs 4.8%) and MR ≤2+ (96.5% vs 96.8%), respectively. Functional and quality-of-life outcomes significantly improved in both groups (P < 0.05). The proportion of patients with MR ≤1+ was durable in the PASCAL group from discharge to 6 months (PASCAL, 87.2% and 83.7% [P = 0.317 vs discharge]; MitraClip, 88.5% and 71.2% [P = 0.003 vs discharge]). CONCLUSIONS: The CLASP IID trial demonstrated safety and effectiveness of the PASCAL system and met noninferiority endpoints, expanding transcatheter treatment options for prohibitive surgical risk patients with significant symptomatic DMR.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Cardiac Catheterization/adverse effects , Heart Valve Prosthesis Implantation/adverse effects , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Quality of Life , Treatment Outcome
13.
J Cardiothorac Vasc Anesth ; 36(9): 3469-3474, 2022 09.
Article in English | MEDLINE | ID: mdl-35688758

ABSTRACT

Intraprocedural transesophageal echocardiography imaging is an integral part of percutaneous structural heart disease (SHD) interventions. The rapid growth in the number, scope, and complexity of SHD interventions has outpaced the efforts to develop training and proficiency standards in periprocedural imaging. At the Beth Israel Deaconess Medical Center in Boston, Massachusetts, the authors have developed a 6-month duration fellowship in interventional echocardiography for SHD to address this issue. The purpose of this fellowship is to train cardiac anesthesiologists to address the unique challenges of interventional echocardiography. In this paper, the authors describe the rationale for and specific features of this training program. Their fellowship curriculum follows a multimodal integrative approach to training in SHD imaging, which includes simulation sessions, online modules, deliberate practice in the clinical setting, and interdisciplinary team-based training. In the next several years, there will be an increased need for echocardiographers who are proficient in intraprocedural SHD imaging. In this article, the authors describe their experience with a competency-based curriculum for subspecialty anesthesia training in SHD imaging.


Subject(s)
Anesthesia , Heart Diseases , Internship and Residency , Adult , Curriculum , Echocardiography, Transesophageal , Heart Diseases/diagnostic imaging , Humans
14.
JACC Cardiovasc Interv ; 15(7): 728-738, 2022 04 11.
Article in English | MEDLINE | ID: mdl-35393106

ABSTRACT

OBJECTIVES: This study sought to evaluate patient-centered metrics in intermediate-surgical-risk aortic stenosis patients enrolled in the SURTAVI (Surgical Replacement and Transcatheter Aortic Valve Implantation) trial treated with self-expanding transcatheter aortic valve replacement (TAVR) or surgery. BACKGROUND: Studies have shown TAVR to be an alternative to surgery in patients with severe symptomatic aortic stenosis but have focused on "hard endpoints," including all-cause mortality and stroke, rather than on comparative patient-centered metrics, such as functional status and symptom burden. METHODS: The study analyzed functional status (6-minute walk test [6MWT]) and symptom burden (Kansas City Cardiomyopathy Questionnaire) in 1,492 patients from the SURTAVI trial at baseline, 30 days, 1 year, and 2 years. Patients were categorized by baseline functional status into tertiles of slow, medium, and fast walkers. RESULTS: Patients with lowest capacity baseline functional status were commonly women, had higher Society of Thoracic Surgeons scores, and had more New York Heart Association functional class III or IV symptoms; reduced baseline functional status was associated with higher aortic valve- and heart failure-related hospitalization at 2 years. There was greater improvement in 6MWT distance in TAVR compared with surgery patients at 30 days (P < 0.001) and 1 year (P = 0.012), but at 2 years, both groups had similar improvement (P = 0.091). The percentage of patients with large improvement in 6MWT was greatest in patients categorized as slow walkers and lowest in fast walkers. Symptom burden improved after TAVR at 30 days and after both procedures at 1 and 2 years. CONCLUSIONS: In this substudy of patients from the SURTAVI trial, patients receiving TAVR demonstrated a more rapid improvement in functional status and symptom burden compared with patients undergoing surgery; however, both groups had similar improvements in long-term follow-up. (Safety and Efficacy Study of the Medtronic CoreValve® System in the Treatment of Severe, Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement [SURTAVI]; NCT01586910).


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Female , Functional Status , Humans , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
15.
J Cardiothorac Vasc Anesth ; 36(8 Pt B): 3156-3162, 2022 08.
Article in English | MEDLINE | ID: mdl-35279368

ABSTRACT

PATENT FORAMEN ovales (PFOs) and atrial septal defects (ASDs) are 2 examples of interatrial septal pathology.1 The presence of a PFO is a well-known risk factor for cryptogenic stroke.1,2 Newer evidence over the course of the last decade suggests percutaneous device closure of PFOs significantly reduces the subsequent risk of recurrent stroke.2 Among ASDs, the ostium secundum type is the most common pathology and, due to its anatomy, is most amenable to transcatheter closure.1 The tools that are available to percutaneously close these different pathologies vary, and choosing the correct device for the procedure can have significant impact on the clinical outcome. The authors here present a case that highlights how the differentiation of an ASD from a PFO using 2-dimensional (2D) and 3-dimensional (3D) echocardiography can affect the clinical decision-making and outcome in a challenging structural heart disease case.


Subject(s)
Atrial Septum , Echocardiography, Three-Dimensional , Foramen Ovale, Patent , Heart Septal Defects, Atrial , Atrial Septum/diagnostic imaging , Atrial Septum/surgery , Cardiac Catheterization/methods , Echocardiography, Transesophageal/methods , Foramen Ovale, Patent/diagnostic imaging , Foramen Ovale, Patent/surgery , Heart Septal Defects, Atrial/diagnostic imaging , Heart Septal Defects, Atrial/surgery , Humans , Treatment Outcome
17.
Am J Cardiol ; 158: 104-111, 2021 11 01.
Article in English | MEDLINE | ID: mdl-34465458

ABSTRACT

Durability of transcatheter heart valve (THV) is critical as the indication of transcatheter aortic valve implantation (TAVI) expands to patients with longer life-expectancy. We aimed to compare the durability of different THV systems (balloon-expandable [BE] and self-expandable [SE]) and surgical aortic valve replacement (SAVR) prosthesis. PUBMED and EMBASE were searched through February 2021 for randomized trials investigating parameters of valve durability after TAVI and/or SAVR in severe aortic stenosis. A network meta-analysis using random-effect model was performed. Synthesis was performed with 5-year follow-up data for echocardiographic outcomes and the longest available follow-up data for clinical outcomes. Ten trials with a total of 9,388 patients (BE-THV: 2,562; SE-THV: 2,863; SAVR: 3,963) were included. Follow-up ranged from 1 to 6 years. SE-THV demonstrated significantly larger effective orifice area, lower mean aortic valve gradient (AVG), and less increase in mean AVG at 5-year compared with BE-THV and SAVR. Structural valve deterioration (SVD) was less frequent in SE-THV compared with BE-THV and SAVR (HR 0.14, 95% CI 0.07 to 0.27; HR 0.34, 95% CI 0.24 to 0.47, respectively). Total moderate-severe aortic regurgitation and reintervention was more frequent in BE-THV (HR 4.21, 95% CI 2.40 to 7.39; HR 2.22, 95% CI 1.16 to 4.26, respectively), and SE-THV (HR 7.51, 95% CI 3.89 to 14.5; HR 2.86, 95% CI 1.59 to 5.13, respectively) compared with SAVR. In conclusion, TAVI with SE-THV demonstrated favorable forward-flow hemodynamics and lowest risk of SVD compared with BE-THV and SAVR at mid-term. However, both THV systems suffer an increased risk of AR and re-intervention, and long-term data from newer generation valves is warranted.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve , Bioprosthesis , Heart Valve Prosthesis , Prosthesis Failure , Humans
19.
Echocardiography ; 38(8): 1425-1429, 2021 08.
Article in English | MEDLINE | ID: mdl-34231251

ABSTRACT

Quite often the iatrogenic atrial septal defect created after percutaneous transcatheter mitral valve replacement procedures is closed with an atrial septal occluder device thus precluding further transseptal interventions if required. In this case report, we describe a patient who previously underwent a valve-in-valve transcatheter mitral valve replacement and iatrogenic atrial septal defect closure with an Amplatzer device, who developed severe prosthetic mitral valve stenosis. This patient required a second percutaneous valve-in-valve in-valve procedure with a transseptal puncture in the presence of an atrial septal occluder device.


Subject(s)
Heart Septal Defects, Atrial , Septal Occluder Device , Cardiac Catheterization , Heart Septal Defects, Atrial/diagnostic imaging , Heart Septal Defects, Atrial/surgery , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Punctures
20.
J Cardiovasc Comput Tomogr ; 15(6): 485-491, 2021.
Article in English | MEDLINE | ID: mdl-34024757

ABSTRACT

BACKGROUND: Few data exist on long-term outcome in patients undergoing combined coronary CT angiography (CTA) and myocardial CT perfusion imaging (CTP) as well as invasive coronary angiography (ICA) and single photon emission tomography (SPECT). METHODS: At 16 centers, 381 patients were followed for major adverse cardiac events (MACE) for the CORE320 study. All patients underwent coronary CTA, CTP, and SPECT before ICA within 60 days. Prognostic performance according binary results (normal/abnormal) was assessed by 5-year major cardiovascular events (MACE) free survival and area under the receiver-operating-characteristic curve (AUC). RESULTS: Follow up beyond 2-years was available in 323 patients. MACE-free survival rate was greater among patients with normal combined CTA-CTP findings compared to ICA-SPECT: 85 vs. 80% (95% confidence interval [CI] for difference 0.1, 11.3) though event-free survival time was similar (4.54 vs. 4.37 years, 95% CI for difference: -0.03, 0.36). Abnormal results by combined CTA-CTP was associated with 3.83 years event-free survival vs. 3.66 years after abnormal combined ICA-SPECT (95% CI for difference: -0.05, 0.39). Predicting MACE by AUC also was similar: 65 vs. 65 (difference 0.1; 95% CI -4.6, 4.9). When MACE was restricted to cardiovascular death, myocardial infarction, or stroke, AUC for CTA-CTP was 71 vs. 60 by ICA-SPECT (difference 11.2; 95% CI -1.0, 19.7). CONCLUSIONS: Combined CTA-CTP evaluation yields at least equal 5-year prognostic information as combined ICA-SPECT assessment in patients presenting with suspected coronary artery disease. Noninvasive cardiac CT assessment may eliminate the need for diagnostic cardiac catheterization in many patients. CLINICAL TRIAL REGISTRATION: NCT00934037.


Subject(s)
Coronary Artery Disease , Myocardial Perfusion Imaging , Computed Tomography Angiography , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Follow-Up Studies , Humans , Predictive Value of Tests , Prognosis , Prospective Studies , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL
...