Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Altern Ther Health Med ; 29(8): 924-928, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37708565

ABSTRACT

Objective: This study aimed to evaluate the clinical efficacy of an enhanced minimally invasive NICE joint technique combined with dual adjustable loop steel plate internal fixation for treating acute acromioclavicular joint dislocation. Methods: A retrospective analysis was conducted on 63 surgical patients treated with acute acromioclavicular joint dislocation from May 2017 to March 2022. Among them, 33 cases were treated with the clavicle hook plate, and 30 cases were treated with the minimally invasive loop plate. We compared hospitalization duration, incision length, surgical duration, intraoperative bleeding, visual analogue pain scale scores, shoulder joint Constant scores at 6 months before and after surgery, and the incidence of complications between the two groups. Results: The comparison between the two groups, including hospitalization duration, incision length, surgical duration, intraoperative bleeding volume, and shoulder joint Constant score at 6 months post-surgery, revealed statistically significant differences where the loop plate group had better results. One case (1/33) experienced postoperative complications in the hook plate group, including screw loosening and plate failure. Additionally, there were 8 cases (8/33) of subacromial osteolysis, 10 cases (10/33) of acromial impact, and 5 cases (5/33) of residual shoulder pain. Conversely, only 1 case (1/30) in the loop plate group had residual shoulder pain. Conclusions: The surgical technique involving the reconstruction of the coracoclavicular ligament using an enhanced minimally invasive NICE junction combined with double adjustable loop steel plate placement in the clavicular small bone canal is characterized by simplicity, safety, minimal invasiveness, excellent functional recovery, fewer complications, and superior clinical efficacy compared to clavicular hook steel plates.


Subject(s)
Acromioclavicular Joint , Joint Dislocations , Shoulder Dislocation , Humans , Joint Dislocations/surgery , Retrospective Studies , Acromioclavicular Joint/surgery , Shoulder Pain , Shoulder Dislocation/surgery , Treatment Outcome , Steel
2.
Opt Express ; 24(2): 1409-15, 2016 Jan 25.
Article in English | MEDLINE | ID: mdl-26832522

ABSTRACT

The study is focused on the asymmetric secondary freeform lens (ASFL) design for creating a low glared light-emitting diode (LED) street light. The lens is mounted on a chip on board (COB) LED as the new LED street light module to perform a non-axial symmetric light intensity distribution. The experimental results show that the street light can work without inclining lamps and reach Chinese National Standards (CNS) and Illuminating Engineering Society of North America (IESNA) standards at the same time.

3.
Appl Opt ; 54(28): E69-74, 2015 Oct 01.
Article in English | MEDLINE | ID: mdl-26479667

ABSTRACT

A novel LED fishing/working light is proposed to enhance the lighting efficiency of a fishing boat. The study is focused on the freeform secondary lens design so as to create a lamp that attracts fish and sheds light on the deck for the crew's work. The experimental results show that the proposed multisegmented freeform lens can deliver the proposed aim, giving 3 times as much illuminating power as the traditional high-intensity discharge fishing lamp does with the same input of electrical power.

4.
Appl Opt ; 53(29): H140-5, 2014 Oct 10.
Article in English | MEDLINE | ID: mdl-25322411

ABSTRACT

A free-form secondary lens is proposed to optimize an LED light. Based on Snell's law, energy conservation law, and a Monte Carlo ray-tracing algorithm, the surface contour of the free-form lens can be determined according to the requirements of an LED light. Optical experimental results show that an optical efficiency of 95.69% can be achieved by the lens, of which the illumination uniformity 0.317 is higher than the commercial illumination uniformity 0.259. The lens does not need the help of a white ring holder, so the cost of the LED light can become effective.

SELECTION OF CITATIONS
SEARCH DETAIL
...