Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Chin Med Assoc ; 86(5): 459-464, 2023 05 01.
Article in English | MEDLINE | ID: mdl-36800256

ABSTRACT

Lead (Pb) poisoning can damage human bodies silently, without specific symptoms or conspicuous warning signs. To provide safe and user-friendly tools for detecting heavy metals at low concentrations, scientists have developed and optimized versatile biosensors. To practically employ the developed biosensors specific for Pb (eg, the optimized Met-lead 1.44 M1), smartphone applications designed for user convenience and are easily operable for the on-site detection of Pb in environmental water, drinking water, food, and blood/urine are urgently needed. To establish a monitoring system for home health maintenance, a portable device and useful apps installed on a smartphone can be integrated, and the data acquired can be sent to and stored in the cloud for further analysis and evidence preservation. With the high transmissions speeds for 4G and 4G wireless Internet, such a system can be applied for health protection; water-quality data can be provided by anyone and publicly shared for display on smartphone interfaces, alerting individuals of heavy metal contamination. In this review, we describe recent developments in heavy metal-sensing devices, including home health maintenance systems, which have been successfully and practically applied to prevent heavy metal Pb poisoning.


Subject(s)
Lead Poisoning , Metals, Heavy , Mobile Applications , Humans , Lead , Lead Poisoning/diagnosis , Lead Poisoning/prevention & control , Water
2.
J Chin Med Assoc ; 86(2): 138-146, 2023 02 01.
Article in English | MEDLINE | ID: mdl-36227021

ABSTRACT

COVID-19 has greatly affected human life for over 3 years. In this review, we focus on smart healthcare solutions that address major requirements for coping with the COVID-19 pandemic, including (1) the continuous monitoring of severe acute respiratory syndrome coronavirus 2, (2) patient stratification with distinct short-term outcomes (eg, mild or severe diseases) and long-term outcomes (eg, long COVID), and (3) adherence to medication and treatments for patients with COVID-19. Smart healthcare often utilizes medical artificial intelligence (AI) and cloud computing and integrates cutting-edge biological and optoelectronic techniques. These are valuable technologies for addressing the unmet needs in the management of COVID. By leveraging deep learning/machine learning capabilities and big data, medical AI can perform precise prognosis predictions and provide reliable suggestions for physicians' decision-making. Through the assistance of the Internet of Medical Things, which encompasses wearable devices, smartphone apps, internet-based drug delivery systems, and telemedicine technologies, the status of mild cases can be continuously monitored and medications provided at home without the need for hospital care. In cases that develop into severe cases, emergency feedback can be provided through the hospital for rapid treatment. Smart healthcare can possibly prevent the development of severe COVID-19 cases and therefore lower the burden on intensive care units.


Subject(s)
COVID-19 , Humans , Artificial Intelligence , Post-Acute COVID-19 Syndrome , Pandemics/prevention & control , Delivery of Health Care
3.
Biosensors (Basel) ; 12(3)2022 Mar 02.
Article in English | MEDLINE | ID: mdl-35323427

ABSTRACT

Most methods for measuring environmental lead (Pb) content are time consuming, expensive, hazardous, and restricted to specific analytical systems. To provide a facile, safe tool to detect Pb, we created pMet-lead, a portable fluorescence resonance energy transfer (FRET)-based Pb-biosensor. The pMet-lead device comprises a 3D-printed frame housing a 405-nm laser diode-an excitation source for fluorescence emission images (YFP and CFP)-accompanied by optical filters, a customized sample holder with a Met-lead 1.44 M1 (the most recent version)-embedded biochip, and an optical lens aligned for smartphone compatibility. Measuring the emission ratios (Y/C) of the FRET components enabled Pb detection with a dynamic range of nearly 2 (1.96), a pMet-lead/Pb dissociation constant (Kd) 45.62 nM, and a limit of detection 24 nM (0.474 µg/dL, 4.74 ppb). To mitigate earlier problems with a lack of selectivity for Pb vs. zinc, we preincubated samples with tricine, a low-affinity zinc chelator. We validated the pMet-lead measurements of the characterized laboratory samples and unknown samples from six regions in Taiwan by inductively coupled plasma mass spectrometry (ICP-MS). Notably, two unknown samples had Y/C ratios significantly higher than that of the control (3.48 ± 0.08 and 3.74 ± 0.12 vs. 2.79 ± 0.02), along with Pb concentrations (10.6 ppb and 15.24 ppb) above the WHO-permitted level of 10 ppb in tap water, while the remaining four unknowns showed no detectable Pb upon ICP-MS. These results demonstrate that pMet-lead provides a rapid, sensitive means for on-site Pb detection in water from the environment and in living/drinking supply systems to prevent potential Pb poisoning.


Subject(s)
Biosensing Techniques , Fluorescence Resonance Energy Transfer , Biosensing Techniques/methods , Fluorescence Resonance Energy Transfer/methods , Smartphone , Water
4.
J Chin Med Assoc ; 84(8): 745-753, 2021 08 01.
Article in English | MEDLINE | ID: mdl-34225337

ABSTRACT

The detrimental impact of the heavy metal lead (Pb) on human health has been studied for years. The fact that Pb impairs human body has been established from countless painful and sad historical events. Nowadays, World Health Organization and many developmental countries have established regulations concerning the use of Pb. Measuring the blood lead level (BLL) is so far the only way to officially evaluate the degree of Pb exposure, but the so-called safety value (10 µg/dL in adults and 5 µg/dL in children) seems unreliable to represent the security checkpoint for children through daily intake of drinking water or physical contact with a lower contaminated level of Pb contents. In general, unsolved mysteries about the Pb toxicological mechanisms still remain. In this review article, we report on the methods to prevent Pb poison for further Pb toxicological research. We establish high-sensitivity Pb monitoring, and also report on the use of fluorescent biosensors such as genetically-encoded fluorescence resonance energy transfer-based biosensors built for various large demands such as the detection of severe acute respiratory syndrome coronavirus 2. We also contribute to the development and optimization of the FRET-based Pb biosensors. Our well-performed version of Met-lead 1.44 M1 has achieved a limit of detection of 10 nM (2 ppb; 0.2 µg/dL) and almost 5-fold in dynamic range (DR) supported for the real practical applications-that is, the in-cell Pb sensing device for blood and blood-related samples, and the Pb environmental detections in vitro. The perspective of our powerful Pb biosensor incorporated with a highly sensitive bio-chip of the portable device for quick Pb measurements will be addressed for further manipulation.


Subject(s)
Biosensing Techniques/methods , Fluorescence Resonance Energy Transfer/methods , Lead/analysis , Environment
5.
Sensors (Basel) ; 20(6)2020 Mar 19.
Article in English | MEDLINE | ID: mdl-32204388

ABSTRACT

The harmful impact of the heavy metal lead on human health has been known for years. However, materials that contain lead remain in the environment. Measuring the blood lead level (BLL) is the only way to officially evaluate the degree of exposure to lead. The so-called "safe value" of the BLL seems to unreliably represent the secure threshold for children. In general, lead's underlying toxicological mechanism remains unclear and needs to be elucidated. Therefore, we developed a novel genetically encoded fluorescence resonance energy transfer (FRET)-based lead biosensor, Met-lead, and applied it to transgenic Drosophila to perform further investigations. We combined Met-lead with the UAS-GAL4 system to the sensor protein specifically expressed within certain regions of fly brains. Using a suitable imaging platform, including a fast epifluorescent or confocal laser-scanning/two-photon microscope with high resolution, we recorded the changes in lead content inside fly brains ex vivo and in vivo and at different life stages. The blood-brain barrier was found to play an important role in the protection of neurons in the brain against damage due to the heavy metal lead, either through food or microinjection into the abdomen. Met-lead has the potential to be a powerful tool for the sensing of lead within living organisms by employing either a fast epi-FRET microscope or high-resolution brain imaging.


Subject(s)
Biosensing Techniques , Drosophila melanogaster/chemistry , Lead/isolation & purification , Metals, Heavy/isolation & purification , Animals , Lead/chemistry , Metals, Heavy/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...