Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Med Phys ; 29(11): 2649-54, 2002 Nov.
Article in English | MEDLINE | ID: mdl-12462732

ABSTRACT

Mammographic imaging uses x-ray tubes with molybdenum, rhodium, or tungsten anodes with the produced bremsstrahlung filtered by thin sheets of molybdenum, rhodium, or aluminum. The National Institute of Standards and Technology, the Accredited Dosimetry Calibration Laboratories, and several manufacturers offer calibrations of mammography ionization chambers with reference x-ray beams with different radiation qualities in the range 23-40 kVp. The energy response of ten commercially available chambers was determined for these reference radiation qualities using the Attix variable-length free-air chamber. The evaluated chambers are designed with thin entrance windows of varying thickness and composition. The chambers show variation in their air kerma response as a function of beam radiation quality. This response with beam radiation quality may affect the measurement of clinical beam half value layer (HVL) and the determination of the mean glandular dose. The combined effect of the chamber's energy dependence and HVL measurement affects the mean glandular dose calculation resulting in differences ranging from -1.8% to +2.5%.


Subject(s)
Equipment Failure Analysis/standards , Mammography/instrumentation , Mammography/standards , Radiometry/methods , Radiometry/standards , Calibration/standards , Equipment Failure Analysis/methods , Humans , Radiation Dosage , Reference Standards , Reproducibility of Results , Sensitivity and Specificity , United States
2.
Phys Rev Lett ; 88(15): 152501, 2002 Apr 15.
Article in English | MEDLINE | ID: mdl-11955192

ABSTRACT

The latest generation gamma-ray detection system, GAMMASPHERE, coupled with the Microball charged-particle detector, has made possible a new class of nuclear lifetime measurement. For the first time differential lifetime measurements free from common systematic errors for over 15 different nuclei ( >30 rotational bands in various isotopes of Ce, Pr, Nd, Pm, and Sm) have been extracted at high spin within a single experiment. This comprehensive study establishes the effective single-particle transition quadrupole moments in the A approximately 135 light rare-earth region. Detailed comparisons are made with theoretical calculations using the self-consistent cranked mean-field theory which convincingly demonstrates the validity of the additivity of single-particle quadrupole moments in this mass region.

SELECTION OF CITATIONS
SEARCH DETAIL
...