Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Circ Arrhythm Electrophysiol ; 15(9): e010954, 2022 09.
Article in English | MEDLINE | ID: mdl-36074954

ABSTRACT

BACKGROUND: Data on atrial fibrillation (AF) ablation and outcomes are limited in patients with congenital heart disease (CHD). We aimed to investigate the characteristics of patients with CHD presenting for AF ablation and their outcomes. METHODS: A multicenter, retrospective analysis was performed of patients with CHD undergoing AF ablation between 2004 and 2020 at 13 participating centers. The severity of CHD was classified using 2014 Pediatric and Congenital Electrophysiology Society/Heart Rhythm Society guidelines. Clinical data were collected. One-year complete procedural success was defined as freedom from atrial tachycardia or AF in the absence of antiarrhythmic drugs or including previously failed antiarrhythmic drugs (partial success). RESULTS: Of 240 patients, 127 (53.4%) had persistent AF, 62.5% were male, and mean age was 55.2±13.3 years. CHD complexity categories included 147 (61.3%) simple, 68 (28.3%) intermediate, and 25 (10.4%) severe. The most common CHD type was atrial septal defect (n=78). More complex CHD conditions included transposition of the great arteries (n=14), anomalous pulmonary veins (n=13), tetralogy of Fallot (n=8), cor triatriatum (n=7), single ventricle physiology (n=2), among others. The majority (71.3%) of patients had trialed at least one antiarrhythmic drug. Forty-six patients (22.1%) had reduced systemic ventricular ejection fraction <50%, and mean left atrial diameter was 44.1±8.2 mm. Pulmonary vein isolation was performed in 227 patients (94.6%); additional ablation included left atrial linear ablations (40%), complex fractionated atrial electrogram (19.2%), and cavotricuspid isthmus ablation (40.8%). One-year complete and partial success rates were 45.0% and 20.5%, respectively, with no significant difference in the rate of complete success between complexity groups. Overall, 38 patients (15.8%) required more than one ablation procedure. There were 3 (1.3%) major and 13 (5.4%) minor procedural complications. CONCLUSIONS: AF ablation in CHD was safe and resulted in AF control in a majority of patients, regardless of complexity. Future work should address the most appropriate ablation targets in this challenging population.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Heart Defects, Congenital , Pulmonary Veins , Transposition of Great Vessels , Adult , Aged , Anti-Arrhythmia Agents/therapeutic use , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Child , Female , Heart Defects, Congenital/complications , Humans , Male , Middle Aged , Pulmonary Veins/surgery , Registries , Retrospective Studies , Treatment Outcome
2.
Circ Arrhythm Electrophysiol ; 11(12): e006730, 2018 12.
Article in English | MEDLINE | ID: mdl-30562104

ABSTRACT

BACKGROUND: Several distinct risk factors for arrhythmia recurrence and mortality following ventricular tachycardia (VT) ablation have been described. The effect of concurrent risk factors has not been assessed so far; thus, it is not yet possible to estimate these risks for a patient with several comorbidities. The aim of the study was to identify specific risk groups for mortality and VT recurrence using the Survival Tree (ST) analysis method. METHODS: In 1251 patients 16 demographic, clinical and procedure-related variables were evaluated as potential prognostic factors using ST analysis using a recursive partitioning algorithm that searches for relationships among variables. Survival time and time to VT recurrence in groups derived from ST analysis were compared by a log-rank test. A random forest analysis was then run to extract a variable importance index and internally validate the ST models. RESULTS: Left ventricular ejection fraction, implantable cardioverter defibrillator/cardiac resynchronization device, previous ablation were, in hierarchical order, identified by ST analysis as best predictors of VT recurrence, while left ventricular ejection fraction, previous ablation, Electrical storm were identified as best predictors of mortality. Three groups with significantly different survival rates were identified. Among the high-risk group, 65.0% patients were survived and 52.1% patients were free from VT recurrence; within the medium- and low-risk groups, 84.0% and 97.2% patients survived, 72.4% and 88.4% were free from VT recurrence, respectively. CONCLUSIONS: Our study is the first to derive and validate a decisional model that provides estimates of VT recurrence and mortality with an effective classification tree. Preprocedure risk stratification could help optimize periprocedural and postprocedural care.


Subject(s)
Catheter Ablation/mortality , Electrocardiography/methods , Tachycardia, Ventricular/mortality , Tachycardia, Ventricular/surgery , Age Factors , Aged , Aged, 80 and over , Catheter Ablation/methods , Cohort Studies , Databases, Factual , Decision Trees , Follow-Up Studies , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Predictive Value of Tests , ROC Curve , Recurrence , Retrospective Studies , Risk Assessment , Severity of Illness Index , Sex Factors , Stroke Volume/physiology , Survival Analysis , Tachycardia, Ventricular/diagnostic imaging , Time Factors , Treatment Outcome
3.
Heart Rhythm ; 15(1): 48-55, 2018 01.
Article in English | MEDLINE | ID: mdl-28843418

ABSTRACT

OBJECTIVE: The purpose of this study was to evaluate the characteristics and outcome of patients undergoing ablation after electrical storm (ES). METHODS: Clinical and procedural characteristics, ventricular tachycardia (VT) recurrence, and mortality rates from 1940 patients undergoing VT ablation were compared between patients with and without ES. RESULTS: The group of 677 patients with ES (34.9%) were older, were more frequently men, and had a lower ejection fraction, more advanced heart failure, and a higher prevalence of cardiovascular comorbidities as compared with those without ES (86.1% patients with ES had ≥2 comorbidities vs 71.4%; P < .001). Patients with ES had more inducible VTs (2.5 ± 1.8 vs 1.9 ± 1.9; P < .001), required longer procedures (296.1 ± 119.1 minutes vs 265.7 ± 110.3 minutes; P < .001), and had a higher in-hospital mortality (42 deaths [6.2%] vs 18 deaths [1.4%]; P < .001). At 1-year follow-up, patients with ES experienced a higher risk of VT recurrence and mortality (32.1% vs 22.6% and 20.1% vs 8.5%; long-rank, P < .001 for both). Among patients with ES, those without any inducible VT after ablation had a higher survival rate (86.3%) than did those with nonclinical VTs only (72.9%), those with clinical VTs inducible at programmed electrical stimulation (51.2%), and not-tested patients (65.0%) (long-rank, P < .001 for all). In multivariate analysis, ES remained an independent predictor of in-hospital mortality, VT recurrence, and 1-year mortality (P < .001). CONCLUSION: Patients with ES have a high risk of VT recurrence and mortality. Patient and procedure characteristics are consistent with advanced cardiac disease and longer and more complex procedures. In patients with ES, acute procedural success is associated with a significant reduction in VT recurrence and improved 1-year survival.


Subject(s)
Catheter Ablation/methods , Heart Conduction System/physiopathology , Tachycardia, Ventricular/surgery , Electrocardiography , Female , Heart Conduction System/surgery , Humans , Italy/epidemiology , Male , Middle Aged , Recurrence , Survival Rate/trends , Tachycardia, Ventricular/mortality , Tachycardia, Ventricular/physiopathology , Treatment Outcome , United States/epidemiology
4.
Acad Emerg Med ; 13(6): 589-95, 2006 Jun.
Article in English | MEDLINE | ID: mdl-16551780

ABSTRACT

OBJECTIVES: The TASER is a conducted electrical weapon (CEW) that has been used on people in custody. Individuals occasionally die unexpectedly while in custody, proximal to the application of a CEW. In this study, the authors sought to examine the effects of CEW application in resting adult volunteers to determine if there was evidence of induced electrical dysrhythmia or direct cellular damage that would indicate a causal relationship between application of the device and in-custody death. METHODS: Human subjects (N = 66) underwent 24-hour monitoring after a standard CEW application. Blood samples were collected before and after exposure and again at 16 and 24 hours after exposure. A subpopulation (n = 32) had 12-lead electrocardiography performed at similar time intervals. Blood samples were analyzed for markers of skeletal and cardiac muscle injury and renal impairment. The electrocardiograms were read by a cardiologist blinded to the study. Data were analyzed using descriptive statistics. RESULTS: There was no significant change from baseline at any of the four time points for serum electrolyte levels and the blood urea nitrogen/creatinine ratio. An increase in serum bicarbonate and creatine kinase levels was noted at 16 and 24 hours. An increase in serum lactate level was noted immediately after exposure that decreased at 16 and 24 hours. Serum myoglobin level was increased from baseline at all three time points. All troponin levels measured were < 0.3 ng/mL, except for a single value of 0.6 ng/mL in a single subject. This subject was evaluated, and no evidence of acute myocardial infarction or disability was identified. At baseline, 30 of 32 electrocardiograms were interpreted as normal. The two abnormal electrocardiograms were abnormal at baseline and remained the same at all four time points. CONCLUSIONS: In this resting adult population, the TASER X26 CEW did not affect the recordable cardiac electrical activity within a 24-hour period following a standard five-second application. The authors were unable to detect any induced electrical dysrhythmias or significant direct cardiac cellular damage that may be related to sudden and unexpected death proximal to CEW exposure. Additionally, no evidence of dangerous hyperkalemia or induced acidosis was found. Further study in the area of the in-custody death phenomenon to better understand its causes is recommended.


Subject(s)
Electroshock/instrumentation , Environmental Exposure/analysis , Environmental Monitoring/methods , Firearms , Adult , Bicarbonates/blood , Biomarkers/blood , Blood Urea Nitrogen , Creatine Kinase/blood , Creatinine/blood , Electric Injuries/blood , Electric Injuries/complications , Electric Injuries/physiopathology , Electrocardiography, Ambulatory , Electrolytes/blood , Female , Heart Diseases/blood , Heart Diseases/diagnosis , Heart Diseases/etiology , Humans , Lactic Acid/blood , Law Enforcement/methods , Male , Middle Aged , Monitoring, Physiologic , Myoglobin/blood , Prospective Studies , Recovery of Function , Rest , Restraint, Physical/instrumentation , Troponin I/blood
SELECTION OF CITATIONS
SEARCH DETAIL
...