Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Ann Am Thorac Soc ; 19(9): 1489-1497, 2022 09.
Article in English | MEDLINE | ID: mdl-35451922

ABSTRACT

Rationale: Lung clearance index (LCI) has good intravisit repeatability with better sensitivity in detecting lung disease on computed tomography scan compared with forced expiratory volume in 1 second (FEV1) in adults with bronchiectasis. Alternative multiple-breath washout parameters have not been systematically studied in bronchiectasis. Objectives: To determine the validity, repeatability, sensitivity, specificity, and feasibility of standard LCI (LCI2.5), shortened LCI (LCI5.0), ventilation heterogeneity arising within proximal conducting airways (ScondVT), and ventilation heterogeneity arising within the acinar airways (SacinVT) in a cross-sectional observational cohort of adults with bronchiectasis. Methods: Cross-sectional multiple-breath nitrogen washout data (Exhalyzer D; Eco Medics AG) from 132 patients with bronchiectasis across five United Kingdom centers (BronchUK Clinimetrics study) and 88 healthy control subjects were analyzed. Results: Within-test repeatability (mean coefficient of variation) was <5% for both LCI2.5 and LCI5.0 in patients with bronchiectasis, and there was no difference in mean coefficient of variation for LCI2.5 and LCI5.0 in patients with bronchiectasis compared with healthy volunteers. Moderate-strength correlations were seen between FEV1 and LCI2.5 (r = -0.54), LCI5.0 (r = -0.53), ScondVT (r = -0.35), and SacinVT (r = -0.38) z-scores. The proportion of subjects with abnormal multiple-breath washout (z-score > 2) but in normal FEV1 (z-score < -2) was 42% (LCI2.5) and 36% (LCI5.0). Overall results from the receiver operating characteristic curve analysis indicated that LCI2.5 had the greatest combined sensitivity and specificity to discriminate between bronchiectasis and control subjects, followed by LCI5.0, FEV1, and ScondVT z-scores. There was a 57% time saving with LCI5.0. Conclusions: LCI2.5 and LCI5.0 had good within-test repeatability and superior sensitivity compared with spirometry measures in differentiating between health and bronchiectasis disease. LCI5.0 is quicker and more feasible than LCI2.5. Clinical trial registered with www.clinicaltrials.gov (NCT02468271).


Subject(s)
Bronchiectasis , Adult , Bronchiectasis/diagnostic imaging , Cross-Sectional Studies , Forced Expiratory Volume , Humans , Lung/diagnostic imaging , Outcome Assessment, Health Care , Respiratory Function Tests
2.
Retina ; 40(6): 1098-1109, 2020 Jun.
Article in English | MEDLINE | ID: mdl-31157714

ABSTRACT

PURPOSE: To compare the impact of the classification of retinal vein occlusion (RVO) into ischemic or nonischemic forms on outcomes after anti-vascular endothelial growth factor therapy. METHODS: Retrospective review of consecutive patients with RVO evaluated at the Belfast Health and Social Care Trust between July 1, 2014, and December 31, 2015. Outcomes, including gain of ≥10 and ≥15 letters at 12 months, mean change in best-corrected visual acuity from baseline to 12 months, resolution of macular edema at 12 months, and development of neovascular complications and epiretinal membrane after anti-vascular endothelial growth factor therapy, were compared between ischemic and nonischemic eyes using regression models. RESULTS: One hundred and seventeen eyes (115 patients), 58 with central RVO and 59 with branch RVO, were included. A greater proportion of eyes with ischemic branch RVO gained ≥10 and ≥15 letters at 12 months than those with nonischemic branch RVO (P = 0.005 and P = 0.016, respectively). No statistically significant differences in visual outcomes were observed between ischemic and nonischemic central RVO. Retinal vein occlusion classification was not associated with anatomical outcomes after treatment. CONCLUSION: Findings support the use of anti-vascular endothelial growth factors in ischemic and nonischemic forms of RVO.


Subject(s)
Angiogenesis Inhibitors/administration & dosage , Ischemia/etiology , Retinal Vein Occlusion/drug therapy , Visual Acuity , Aged , Female , Fluorescein Angiography , Fundus Oculi , Humans , Intravitreal Injections , Ischemia/diagnosis , Ischemia/drug therapy , Male , Prognosis , Retinal Diseases/diagnosis , Retinal Diseases/drug therapy , Retinal Vein Occlusion/complications , Retinal Vein Occlusion/diagnosis , Retrospective Studies , Tomography, Optical Coherence , Vascular Endothelial Growth Factor A/antagonists & inhibitors
3.
Respir Med ; 145: 206-211, 2018 12.
Article in English | MEDLINE | ID: mdl-30509710

ABSTRACT

INTRODUCTION: Multiple Breath Washout (MBW) to measure Lung Clearance Index (LCI) is increasingly being used as a secondary endpoint in multicentre bronchiectasis studies. LCI data quality control or "over-reading" is resource intensive and the impact is unclear. OBJECTIVES: To assess the proportion of MBW tests deemed unacceptable with over-reading, and to assess the change in LCI (number of turnovers), LCI coefficient of variation (CV%) and tidal volume (VT) CV% results after over-reading. METHODS: Data were analysed from 250 MBW tests (from 98 adult bronchiectasis patients) collected as part of the Bronch-UK Clinimetrics study in 5 UK centres. Each MBW test was over-read centrally using pre-defined criteria. MBW tests with <2 technically valid and repeatable trials were deemed unacceptable to include in analysis. In accepted tests, values for LCI, LCI CV% and VT CV% before and after over-reading, were compared. RESULTS: Insufficient data was collected in 10/250 tests. With over-reading, 30/240 (12%) were deemed unacceptable to include in analysis. In those accepted tests, overall the change in LCI, LCI CV% and VT CV% with over-reading was not statistically significant. When MBW new sites were compared to MBW expert sites, the change in LCI with over-reading was significantly greater in MBW new sites (p = 0.047). Data suggests that over-reading could be important up to at least 12 months post initiation of MBW activity. CONCLUSION: MBW over-reading was important in this study as 12% of tests were considered unacceptable. Over-reading improved test result accuracy in sites new to MBW.


Subject(s)
Breath Tests/methods , Bronchiectasis/diagnosis , Quality Control , Aged , Aged, 80 and over , Bronchiectasis/physiopathology , Clinical Trials as Topic , Female , Humans , Lung/physiopathology , Male , Middle Aged , Multicenter Studies as Topic , Sensitivity and Specificity , Time Factors , United Kingdom
SELECTION OF CITATIONS
SEARCH DETAIL
...