Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Cureus ; 16(5): e60386, 2024 May.
Article in English | MEDLINE | ID: mdl-38883021

ABSTRACT

Introduction Recognizing the limitations of traditional direct laryngoscopes, particularly in difficult airway situations, video laryngoscopy has emerged as a potentially safer and more effective alternative. This study evaluated the utility of two 3D-printed video laryngoscopes: a standard geometry video laryngoscope (SGVL), resembling the traditional Macintosh blade, and a hyper-angulated video laryngoscope (HAVL) with a more curved design. Their performance was compared to a standard Macintosh direct laryngoscope across various intubation parameters. By leveraging the cost-effectiveness of 3D printing with polylactic acid, the study aimed to assess the potential of this technology to improve airway management across diverse clinical settings and varying levels of physician expertise. Methods This prospective randomized crossover study compared the effectiveness of 3D-printed video laryngoscopes (VL) and a standard direct laryngoscope in intubation. After obtaining IRB approval, physicians from various specialties across multiple centers participated. Participants received training on SGVL, HAVL, and DL intubation using an instructional video and hands-on practice. The training was standardized for all participants. The primary outcome measures were time to successful intubation, number of attempts, and time to visualize vocal cords. Participants were randomized to use all three laryngoscopes on a manikin, with a maximum of two attempts per scope. A 30-minute break separated each laryngoscope evaluation. Successful intubation was defined as the single insertion of each laryngoscope and bougie, followed by endotracheal tube placement and confirmation of lung inflation. Results Ninety-eight doctors, mostly from the EM team (73.5%) and ICU team (23.4%). Teams consist of consultants, residents, and medical officers of the concerned departments. Forty-eight of the participants (49%) were novice operators (<25 intubations). Successful first-attempt intubation in those with <1 year of experience with intubation (n=33) was highest for SGVL (97%) compared to DL (82%) and HAVL (67%). Participants who learned intubation through self-directed learning exhibited a higher acceptance of VL and achieved 100% success on their first attempt. Among those who followed modules or workshops, 97% had successful first-attempt intubation with VL. The average time taken to visualize the vocal cords was lower in SGVL compared to DL (5.6 vs. 7.5 seconds) (p<0.001). The HAVL also had a lower average time compared to the DL (7.1 vs. 7.5 secs) (p<0.001). However, the time taken to intubate using DL (24.2 ±8.7 sec) was similar to SGVL (28.1 ±13 sec). Lastly, the intubation time using HAVL was the longest (49.6 ±35.5 sec). The time to intubate with DL and SGVL had Spearman's rho of 0.64 (p<0.001), and DL and HAVL had 0.59 (p<0.001). Conclusions The ease of use and its cost-effective nature make 3D-printed VLs beneficial in situations where traditional VLs may not be available, especially in simulation and training.

2.
Cureus ; 15(3): e36581, 2023 Mar.
Article in English | MEDLINE | ID: mdl-37095800

ABSTRACT

This case report highlights the use of point-of-care ultrasound (POCUS) for the diagnosis of ventricular septal rupture (VSR), a severe consequence of acute myocardial infarction (AMI). VSR has a broad spectrum of signs and inconspicuous symptoms, making the diagnosis difficult. POCUS offers non-invasive, real-time cardiac imaging and has an advantage over other methods due to its ability to identify VSR early. Here we present a 63-year-old female with a history of type 2 diabetes, hypothyroidism, hyperlipidemia, and a family history of cardiovascular disease, who came to the ED with chest pain for three days, palpitations, and dyspnea at rest. On examination, the patient was hypotensive, tachycardic, and had crackles with a harsh holosystolic murmur. An EKG and elevated troponin levels suggested acute on chronic anterior-lateral wall ST-elevation myocardial infarction (STEMI). Resuscitation efforts were initiated, followed by a lung ultrasound that revealed good lung sliding and multiple B lines without pleural thickening, indicating pulmonary edema. Echocardiography revealed ischemic heart disease with moderate left ventricle (LV) systolic dysfunction and a 14 mm apical ventricular septal rupture (hypokinetic thinning of the anterior wall, septum, apex, and anterolateral wall with a left ventricular ejection fraction (LVEF) of 39%). The presence of flow on color Doppler across the interventricular septum, showing left-to-right shunting, led to a definitive diagnosis of acute-on-chronic myocardial infarction (MI) with ventricular septal rupture. The case report also emphasizes how modern AI applications like ChatGPT (OpenAI, San Francisco, California, United States), aid in language and research, saving time and redefining the healthcare and research industry. As a result, we are confident that AI-assisted healthcare will be the next global breakthrough.

3.
Cureus ; 13(9): e18113, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34692324

ABSTRACT

Objective The current global COVID-19 pandemic has disrupted supply chains and the production of essential goods and services. This includes personal protective equipment (PPE) kits, respirators, and other protective devices. Hence efforts were made to prototype and produce 3D-printed N95 respirators to fill the gap in supply. In addition, methods of sterilization were put into place for the respirators. As well as forming standard operating procedures. Methods With the use of vast open-source libraries and collaboration with engineers and doctors fighting the COVID-19 pandemic, respirator prototypes were produced with special consideration to the sizing to fit median facial sizes. Polymer plastics were mixed in various proportions to condition the respirator to be used by frontline workers in austere environments. Due to the shortage of medical-grade filter media, alternative sources were researched. Merv 13 and Merv 15 filters were selected due to their cheap costs, vast abundance, and proven filtration efficacy against particles of 0.03 microns. Studies conducted around the world have also shown its efficacy as an alternative to medical-grade air filter media. After developing standard operating procedures (SOPs) for sterilisation and respirator usage. Emergency approval was obtained and a limited number of healthcare workers were issued with this respirator (n=400). PPE kit satisfaction and self-efficacy scores were calculated from daily questionnaires during donning and doffing Results Qualitative fit-tests in all 400 healthcare workers matched those of a conventional N95 respirator. Almost all of the respondents in the PPE kit satisfaction responded positively. The self-efficacy score calculated from the general self-efficiency scale had an overall positive value, with the average score being 4.29. This demonstrated that the self-efficacy score was above average and indicated a high motivation to overcome obstacles and spend more time solving problems. The average self-efficacy score is defined between 2.5 - 3.5, and a low self-efficacy score is defined as a score below 2.5. Lastly, a regression analysis was done to test the correlation between PPE kit satisfaction and self-efficiency this demonstrated a positive correlation between PPE kit satisfaction using the 3D-printed respirator and self-efficacy (Slope: 0.416, Intercept: -1.066, R-value: 0.872, P-value: <0.01) Conclusions With supply chain disruptions and reduced or nonexistent supplies of essential medical goods. The need of a reusable, sterilisable, and efficient respirator has never been more evident. The materials used have made it sustain heavy use in austere environments. Studies have reported higher than average burnout rates in COVID-19-based healthcare workers. Studies have also shown that the rates of burnout are high in healthcare professionals without access to proper PPE kits in developing nations. This respirator was rated highly in PPE kit satisfaction and the self-efficacy score. Studies have demonstrated a correlation between high self-efficacy scores and low burnout rates in health care workers. There is also documented evidence of a positive correlation between high self-efficacy scores and general health. As the pandemic continues to evolve, so will the efforts to combat it, such as 3D printing. Interdisciplinary collaboration continues to drive our efforts to combat the pandemic and hopefully resolve it in the future.

SELECTION OF CITATIONS
SEARCH DETAIL
...