Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Publication year range
1.
J Acoust Soc Am ; 155(5): 2948-2958, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38717204

ABSTRACT

Arteriosclerosis is a major risk factor for cardiovascular disease and results in arterial vessel stiffening. Velocity estimation of the pulse wave sent by the heart and propagating into the arteries is a widely accepted biomarker. This symmetrical pulse wave propagates at a speed which is related to the Young's modulus through the Moens Korteweg (MK) equation. Recently, an antisymmetric flexural wave has been observed in vivo. Unlike the symmetrical wave, it is highly dispersive. This property offers promising applications for monitoring arterial stiffness and early detection of atheromatous plaque. However, as far as it is known, no equivalent of the MK equation exists for flexural pulse waves. To bridge this gap, a beam based theory was developed, and approximate analytical solutions were reached. An experiment in soft polymer artery phantoms was built to observe the dispersion of flexural waves. A good agreement was found between the analytical expression derived from beam theory and experiments. Moreover, numerical simulations validated wave speed dependence on the elastic and geometric parameters at low frequencies. Clinical applications, such as arterial age estimation and arterial pressure measurement, are foreseen.


Subject(s)
Models, Cardiovascular , Phantoms, Imaging , Pulse Wave Analysis , Vascular Stiffness , Pulse Wave Analysis/methods , Humans , Elastic Modulus , Computer Simulation , Arteries/physiology , Arteries/physiopathology , Numerical Analysis, Computer-Assisted , Blood Flow Velocity/physiology
3.
Sci Adv ; 9(25): eadf1783, 2023 06 23.
Article in English | MEDLINE | ID: mdl-37343110

ABSTRACT

The risk of cardiovascular events is linked to arterial elasticity that can be estimated from the pulse wave velocity. This symmetric wave velocity is related to the wall elasticity through the Moens-Korteweg equation. However, ultrasound imaging techniques need improved accuracy, and optical measurements on retinal arteries produce inconsistent results. Here, we report the first observation of an antisymmetric pulse wave: the flexural pulse wave. An optical system performs in vivo wave velocity measurements on retinal arteries and veins. Velocity estimation ranges between 1 and 10 millimeter per second. The theory of guided waves confirms the existence of this wave mode and its low velocity. Natural flexural waves can also be detected at the bigger scale of a carotid artery using ultrafast ultrasound imaging. This second natural pulse wave has great potential of becoming a biomarker of blood vessel aging.


Subject(s)
Carotid Arteries , Pulse Wave Analysis , Carotid Arteries/diagnostic imaging , Ultrasonography , Elasticity
4.
J Biomed Opt ; 26(8)2021 08.
Article in English | MEDLINE | ID: mdl-34414704

ABSTRACT

SIGNIFICANCE: Quantitative stiffness information can be a powerful aid for tumor or fibrosis diagnosis. Currently, very promising elastography approaches developed for non-contact biomedical imaging are based on transient shear-waves imaging. Transient elastography offers quantitative stiffness information by tracking the propagation of a wave front. The most common method used to compute stiffness from the acquired propagation movie is based on shear-wave time-of-flight calculations. AIM: We introduce an approach to transient shear-wave elastography with spatially coherent sources, able to yield full-field quantitative stiffness maps with reduced artifacts compared to typical artifacts observed in time-of-flight. APPROACH: A noise-correlation algorithm developed for passive elastography is adapted to spatially coherent narrow or any band sources. This noise-correlation-inspired (NCi) method is employed in parallel with a classic time-of-flight approach. Testing is done on simulation images, experimental validation is conducted with a digital holography setup on controlled homogeneous samples, and full-field quantitative stiffness maps are presented for heterogeneous samples and ex-vivo biological tissues. RESULTS: The NCi approach is first validated on simulations images. Stiffness images processed by the NCi approach on simulated inclusions display significantly less artifacts than with a time-of-flight reconstruction. The adaptability of the NCi algorithm to narrow or any band shear-wave sources was tested successfully. Experimental testing on homogeneous samples demonstrates similar values for both the time-of-flight and the NCi approach. Soft inclusions in agarose sample could be resolved using the NCi method and feasibility on ex-vivo biological tissues is presented. CONCLUSIONS: The presented NCi approach was successful in computing quantitative full-field stiffness maps with narrow and broadband source signals on simulation and experimental images from a digital holography setup. Results in heterogeneous media show that the NCi approach could provide stiffness maps with less artifacts than with time-of-flight, demonstrating that a NCi algorithm is a promising approach for shear-wave transient elastography with spatially coherent sources.


Subject(s)
Elasticity Imaging Techniques , Holography , Algorithms , Artifacts , Phantoms, Imaging
5.
Anal Chem ; 90(20): 11741-11745, 2018 10 16.
Article in English | MEDLINE | ID: mdl-30152689

ABSTRACT

The vast array of molecular isomerisms which form the complex molecular structure of carbohydrates is the foundation of their biological versatility but defies the analytical chemist. Hyphenations of mass spectrometry with orthogonal structural characterization, such as ion mobility or ion spectroscopy, have recently shown great promise for distinction between closely related molecular structures. Yet, the lack of analytical strategies for identification of isomers present in mixtures remains a major obstacle to routine carbohydrate sequencing. In this context, an ideal workflow for glycomics would combine isomer separation and individual characterization of the molecular structure with atomistic resolution. Here we report the implementation of such a multidimensional analytical strategy, which consists of the first online coupling of high-performance liquid chromatography (HPLC)-MS and infrared multiple photon dissociation (IRMPD) spectroscopy. The performance of this novel workflow is exemplified in the case of monosaccharides (anomers) and disaccharides (regioisomers) standards. We report that the LC-MS-IRMPD approach offers a robust advanced MS diagnostic of mixtures of isomers, including carbohydrate anomers, which is critical for carbohydrate sequencing. Our results also explain the bimodal character generally observed in LC chromatograms of carbohydrates. More generally, this multidimensional analytical strategy opens the gateway to rapid identification of molecular isoforms with potential application in the "omics" fields.

SELECTION OF CITATIONS
SEARCH DETAIL
...