Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
N Engl J Med ; 390(3): 212-220, 2024 Jan 18.
Article in English | MEDLINE | ID: mdl-38231622

ABSTRACT

BACKGROUND: The Resynchronization-Defibrillation for Ambulatory Heart Failure Trial (RAFT) showed a greater benefit with respect to mortality at 5 years among patients who received cardiac-resynchronization therapy (CRT) than among those who received implantable cardioverter-defibrillators (ICDs). However, the effect of CRT on long-term survival is not known. METHODS: We randomly assigned patients with New York Heart Association (NYHA) class II or III heart failure, a left ventricular ejection fraction of 30% or less, and an intrinsic QRS duration of 120 msec or more (or a paced QRS duration of 200 msec or more) to receive either an ICD alone or a CRT defibrillator (CRT-D). We assessed long-term outcomes among patients at the eight highest-enrolling participating sites. The primary outcome was death from any cause; the secondary outcome was a composite of death from any cause, heart transplantation, or implantation of a ventricular assist device. RESULTS: The trial enrolled 1798 patients, of whom 1050 were included in the long-term survival trial; the median duration of follow-up for the 1050 patients was 7.7 years (interquartile range, 3.9 to 12.8), and the median duration of follow-up for those who survived was 13.9 years (interquartile range, 12.8 to 15.7). Death occurred in 405 of 530 patients (76.4%) assigned to the ICD group and in 370 of 520 patients (71.2%) assigned to the CRT-D group. The time until death appeared to be longer for those assigned to receive a CRT-D than for those assigned to receive an ICD (acceleration factor, 0.80; 95% confidence interval, 0.69 to 0.92; P = 0.002). A secondary-outcome event occurred in 412 patients (77.7%) in the ICD group and in 392 (75.4%) in the CRT-D group. CONCLUSIONS: Among patients with a reduced ejection fraction, a widened QRS complex, and NYHA class II or III heart failure, the survival benefit associated with receipt of a CRT-D as compared with ICD appeared to be sustained during a median of nearly 14 years of follow-up. (RAFT ClinicalTrials.gov number, NCT00251251.).


Subject(s)
Cardiac Resynchronization Therapy , Defibrillators, Implantable , Heart Failure , Humans , Heart Failure/mortality , Heart Failure/physiopathology , Heart Failure/therapy , Kaplan-Meier Estimate , Stroke Volume , Treatment Outcome , Ventricular Function, Left , Electrocardiography , Follow-Up Studies , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...