Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Biomed Res Int ; 2016: 5958196, 2016.
Article in English | MEDLINE | ID: mdl-27882326

ABSTRACT

Objective. Decreased cardiac function after resuscitation from cardiac arrest (CA) results from global ischemia of the myocardium. In the evolution of postarrest myocardial dysfunction, preferential involvement of any coronary arterial territory is not known. We hypothesized that there is no preferential involvement of any coronary artery during electrical induced ventricular fibrillation (VF) in piglet model. Design. Prospective, randomized controlled study. Methods. 12 piglets were randomized to baseline and electrical induced VF. After 5 min, the animals were resuscitated according to AHA PALS guidelines. After return of spontaneous circulation (ROSC), animals were observed for an additional 4 hours prior to cardiac MRI. Data (mean ± SD) was analyzed using unpaired t-test; p value ≤ 0.05 was considered statistically significant. Results. Segmental wall motion (mm; baseline versus postarrest group) in segment 7 (left anterior descending (LAD)) was 4.68 ± 0.54 versus 3.31 ± 0.64, p = 0.0026. In segment 13, it was 3.82 ± 0.96 versus 2.58 ± 0.82, p = 0.02. In segment 14, it was 2.42 ± 0.44 versus 1.29 ± 0.99, p = 0.028. Conclusion. Postarrest myocardial dysfunction resulted in segmental wall motion defects in the LAD territory. There were no perfusion defects in the involved segments.


Subject(s)
Cardiomyopathies/etiology , Cardiomyopathies/physiopathology , Heart Arrest/etiology , Heart Arrest/physiopathology , Ventricular Fibrillation/complications , Ventricular Fibrillation/physiopathology , Animals , Cardiomyopathies/diagnosis , Coronary Artery Disease/diagnosis , Coronary Artery Disease/etiology , Coronary Artery Disease/physiopathology , Female , Heart Arrest/diagnosis , Male , Stroke Volume , Swine , Ventricular Fibrillation/diagnosis
2.
Resuscitation ; 84(10): 1433-8, 2013 Oct.
Article in English | MEDLINE | ID: mdl-23735651

ABSTRACT

OBJECTIVE: To evaluate the hemodynamic effects of using an adhesive glove device (AGD) to perform active compression-decompression CPR (AGD-CPR) in conjunction with an impedance threshold device (ITD) in a pediatric cardiac arrest model. DESIGN: Controlled, randomized animal study. METHODS: In this study, 18 piglets were anesthetized, ventilated, and continuously monitored. After 3min of untreated ventricular fibrillation, animals were randomized (6/group) to receive either standard CPR (S-CPR), active compression-decompression CPR via adhesive glove device (AGD-CPR) or AGD-CPR along with an ITD (AGD-CPR+ITD) for 2min at 100-120compressions/min. AGD is delivered using a fingerless leather glove with a Velcro patch on the palmer aspect and the counter Velcro patch adhered to the pig's chest. Data (mean±SD) were analyzed using one-way ANOVA with pair wise multiple comparisons to assess differences between groups. p-Value≤0.05 was considered significant. RESULTS: Both AGD-CPR and AGD-CPR+ITD groups produced lower intrathoracic pressure (IttP, mmHg) during decompression phase (-13.4±6.7, p=0.01 and -11.9±6.5, p=0.01, respectively) in comparison to S-CPR (-0.3±4.2). Carotid blood flow (CBF, % of baseline mL/min) was higher in AGD-CPR and AGD-CPR+ITD (respectively 64.3±47.3%, p=0.03 and 67.5±33.1%, p=0.04) as compared with S-CPR (29.1±12.5%). Coronary perfusion pressure (CPP, mmHg) was higher in AGD-CPR and AGD-CPR+ITD (respectively 19.7±4.6, p=0.04 and 25.6±12.1, p=0.02) when compared to S-CPR (9.6±9.1). There was no statistically significant difference between AGD-CPR and AGD-CPR+ITD groups with reference to intra-thoracic pressure, carotid blood flow and coronary perfusion pressure. CONCLUSION: Active compression decompression delivered by this simple and inexpensive adhesive glove device resulted in improved cerebral blood flow and coronary perfusion pressure. There was no statistically significant added effect of ITD use along with AGD-CPR on the decompression of the chest.


Subject(s)
Cardiopulmonary Resuscitation/instrumentation , Cardiopulmonary Resuscitation/methods , Adhesives , Animals , Decompression , Electric Impedance , Female , Gloves, Surgical , Hemodynamics , Male , Swine
3.
Resuscitation ; 83(6): 750-4, 2012 Jun.
Article in English | MEDLINE | ID: mdl-22209832

ABSTRACT

OBJECTIVE: ACD-CPR improves coronary and cerebral perfusion. We developed an adhesive glove device (AGD) and hypothesized that ACD-CPR using an AGD provides better chest decompression resulting in improved carotid blood flow as compared to standard (S)-CPR. DESIGN: Prospective, randomized and controlled animal study. METHODS: Sixteen anesthetized and ventilated piglets were randomized after 3 min of untreated VF to receive either S-CPR or AGD-ACD-CPR by a PALS certified single rescuer with compressions of 100 min(-1) and C:V ratio of 30:2. AGD consisted of a modified leather glove exposing the fingers and thumb. A wide Velcro patch was sewn to the palmer aspect of the glove and the counter Velcro patch was adhered to the pig's chest wall. Carotid blood flow was measured using ultrasound. Data (mean±SD) was analyzed using one way ANOVA and unpaired t-test; p-value ≤ 0.05 was considered statistically significant. RESULTS: Right atrial pressure (mmHg) during the decompression phase was lower during AGD-ACD-CPR (-3.32±2.0) when compared to S-CPR (0.86±1.8, p=0.0007). Mean carotid blood flow was 53.2±27.1 (% of baseline blood flow in ml/min) in AGD vs. 19.1±12.5% in S-CPR, p=0.006. Coronary perfusion pressure (CPP, mmHg) was 29.9±5.8 in AGD vs. 22.7±6.9 in S-CPR, p=0.04. There was no significant difference in time to ROSC and number of epinephrine doses. CONCLUSION: Active chest decompression during CPR using this simple and inexpensive adhesive glove device resulted in significantly better carotid blood flow during the first 2 min of CPR.


Subject(s)
Cardiopulmonary Resuscitation/instrumentation , Carotid Arteries/diagnostic imaging , Heart Arrest/therapy , Hemodynamics , Animals , Blood Flow Velocity , Cardiopulmonary Resuscitation/methods , Carotid Arteries/physiopathology , Coronary Circulation , Female , Heart Arrest/physiopathology , Male , Sus scrofa , Ultrasonography
4.
J Pediatr Intensive Care ; 1(3): 143-151, 2012 Sep.
Article in English | MEDLINE | ID: mdl-31214400

ABSTRACT

The aim of this study was to evaluate the plasma levels of N-Terminal pro-brain natriuretic peptide (N-BNP), N-Terminal pro-atrial natriuretic peptide (N-ANP) and antidiuretic hormone (ADH) over time and their relationship to clinical indicators in hospitalized children with bronchiolitis. Prospective crossover clinical investigation. Hospitalized children in a university-affiliated hospital. Twenty-seven children (birth to 24 mo) with first episode of bronchiolitis and 34 age-matched healthy controls. Daily blood samples up to five consecutive days were obtained for N-BNP, N-ANP and ADH in the bronchiolitis group and on the initial blood draw in the control group. Daily total fluid intake, net fluid balance and clinical bronchiolitis severity levels were recorded. N-BNP and N-ANP levels were measured by enzyme-linked immunosorbent assay. ADH levels were measured by a double antibody technique. The mean age (months ± SD) in the bronchiolitis group was 4.2 ± 5.9 mo and 12.0 ± 6.1 mo in the control group; 51.9% of bronchiolitis patients were positive for respiratory syncytial virus (RSV). In patients with bronchiolitis on admission, plasma N-BNP measurements (mean ± SD) were elevated (996.0 ± 570.2 fmol/mL) compared to controls (552.7 ± 264.7 fmol/mL P < 0.005). Serum N-ANP levels were also initially elevated (3,889 ± 1,769.7 fmol/mL) compared to controls (2,173 ± 912 fmol/mL P < 0.005). The serum levels of N-BNP and N-ANP remained significantly elevated from day 2 through day 5. Similarly, ADH levels were significantly higher on admission in the bronchiolitis group (10 ± 7.49 pg/mL) vs. the control group (5.8 ± 5.5 pg/mL P < 0.05), but quickly decreased from day 2 through day 5. N-BNP, N-ANP and ADH concentrations were elevated in hospitalized children with bronchiolitis at admission. Based on our observation, judicious fluid management is indicated in children hospitalized with bronchiolitis.

5.
Resuscitation ; 81(6): 712-7, 2010 Jun.
Article in English | MEDLINE | ID: mdl-20227156

ABSTRACT

OBJECTIVE: Infant CPR guidelines recommend two-finger chest compression with a lone rescuer and two-thumb with two rescuers. Two-thumb provides better chest compression but is perceived to be associated with increased ventilation hands-off time. We hypothesized that lone rescuer two-thumb CPR is associated with increased ventilation cycle time, decreased ventilation quality and fewer chest compressions compared to two-finger CPR in an infant manikin model. DESIGN: Crossover observational study randomizing 34 healthcare providers to perform 2 min CPR at a compression rate of 100 min(-1) using a 30:2 compression:ventilation ratio comparing two-thumb vs. two-finger techniques. METHODS: A Laerdal Baby ALS Trainer manikin was modified to digitally record compression rate, compression depth and compression pressure and ventilation cycle time (two mouth-to-mouth breaths). Manikin chest rise with breaths was video recorded and later reviewed by two blinded CPR instructors for percent effective breaths. Data (mean+/-SD) were analyzed using a two-tailed paired t-test. Significance was defined qualitatively as p< or =0.05. RESULT: Mean % effective breaths were 90+/-18.6% in two-thumb and 88.9+/-21.1% in two-finger, p=0.65. Mean time (s) to deliver two mouth-to-mouth breaths was 7.6+/-1.6 in two-thumb and 7.0+/-1.5 in two-finger, p<0.0001. Mean delivered compressions per minute were 87+/-11 in two-thumb and 92+/-12 in two-finger, p=0.0005. Two-thumb resulted in significantly higher compression depth and compression pressure compared to the two-finger technique. CONCLUSION: Healthcare providers required 0.6s longer time to deliver two breaths during two-thumb lone rescuer infant CPR, but there was no significant difference in percent effective breaths delivered between the two techniques. Two-thumb CPR had 4 fewer delivered compressions per minute, which may be offset by far more effective compression depth and compression pressure compared to two-finger technique.


Subject(s)
Cardiopulmonary Resuscitation/methods , Infant , Manikins , Adult , Aged , Cross-Over Studies , Female , Fingers , Humans , Male , Middle Aged , Respiration , Single-Blind Method , Thumb , Time Factors , Young Adult
6.
Resuscitation ; 80(10): 1158-63, 2009 Oct.
Article in English | MEDLINE | ID: mdl-19683849

ABSTRACT

OBJECTIVE: We developed an adhesive glove device (AGD) to perform ACD-CPR in pediatric manikins, hypothesizing that AGD-ACD-CPR provides better chest decompression compared to standard (S)-CPR. DESIGN: Split-plot design randomizing 16 subjects to test four manikin-technique models in a crossover fashion to AGD-ACD-CPR vs. S-CPR. Healthcare providers performed 5min of CPR with 30:2 compression:ventilation ratio in the four manikin models: (1) adolescent; (2) child two-hand; (3) child one-hand; and (4) infant two-thumb. METHODS: Modified manikins recorded compression pressure (CP), compression depth (CD) and decompression depth (DD). The AGD consisted of a modified oven mitt with an adjustable strap; a Velcro patch was sewn to the palmer aspect. The counter Velcro patch was bonded to the anterior chest wall. For infant CPR, the thumbs of two oven mitts were stitched together with Velcro. Subjects were asked to actively pull up during decompression. Subjects' heart rate (HR), respiratory rate (RR) and recovery time (RT) for HR/RR to return to baseline were recorded. Subjects were blinded to data recordings. Data (mean+/-SEM) were analyzed using a two-tailed paired t-test. Significance was defined qualitatively as P< or =0.05. RESULTS: Mean decompression depth difference was significantly greater with AGD-ACD-CPR compared to S-CPR; 38-75% of subjects achieved chest decompression to or beyond baseline. AGD-ACD-CPR provided 6-12% fewer chest compressions/minute than S-CPR group. There was no significant difference in CD, CP, HR, RR and RT within each group comparing both techniques. CONCLUSION: A simple, inexpensive glove device for ACD-CPR improved chest decompression with emphasis on active pull in manikins without excessive rescuer fatigue. The clinical implication of fewer compressions/minute in the AGD group needs to be evaluated.


Subject(s)
Cardiopulmonary Resuscitation/instrumentation , Cardiopulmonary Resuscitation/methods , Adolescent , Child , Decompression , Gloves, Surgical , Heart Rate , Humans , Infant , Manikins , Muscle Fatigue , Pressure , Respiratory Rate
SELECTION OF CITATIONS
SEARCH DETAIL
...