PLoS One ; 19(4): e0300956, 2024.
Article in English | MEDLINE | ID: mdl-38630711

ABSTRACT

Increasing the stem size during surgery is associated with a higher incidence of intraoperative periprosthetic fractures in cementless total hip arthroplasty with fully coated tapered wedge stems, especially in femurs of Dorr type A. If in contrast a stem is implanted and sufficient primary stability is not achieved, such preventing successful osseointegration due to increased micromotions, it may also fail, especially if the stem is undersized. Stem loosening or periprosthetic fractures due to stem subsidence can be the consequence. The adaptation of an established stem design to femurs of Dorr type A by design modifications, which increase the stem width proximally combined with a smaller stem tip and an overall shorter stem, might reduce the risk of distal locking of a proximally inadequately fixed stem and provide increased stability. The aim of this study was to investigate whether such a modified stem design provides improved primary stability without increasing the periprosthetic fracture risk compared to the established stem design. The established (Corail, DePuy Synthes, Warsaw, IN, US) and modified stem designs (Emphasys, DePuy Synthes, Warsaw, IN, US) were implanted in cadaveric femur pairs (n = 6 pairs) using the respective instruments. Broaching and implantation forces were recorded and the contact areas between the prepared cavity and the stem determined. Implanted stems were subjected to two different cyclic loading conditions according to ISO 7206-4 using a material testing machine (1 Hz, 600 cycles @ 80 to 800 N, 600 cycles @ 80 to 1600 N). Translational and rotational relative motions between stem and femur were recorded using digital image correlation. Broaching and implantation forces for the modified stem were up to 40% higher (p = 0.024), achieving a 23% larger contact area between stem and bone (R2 = 0.694, p = 0.039) resulting in a four times lower subsidence during loading (p = 0.028). The slight design modifications showed the desired effect in this in-vitro study resulting in a higher primary stability suggesting a reduced risk of loosening. The higher forces required during the preparation of the cavity with the new broaches and during implantation of the stem could bare an increased risk for intraoperative periprosthetic fractures, which did not occur in this study.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Periprosthetic Fractures , Humans , Hip Prosthesis/adverse effects , Periprosthetic Fractures/epidemiology , Prosthesis Design , Arthroplasty, Replacement, Hip/adverse effects , Osseointegration , Femur/surgery , Reoperation/adverse effects , Retrospective Studies
2.
J Orthop Res ; 42(4): 829-836, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37971200

ABSTRACT

The ideal stem size and stem position is important for the success of total hip arthroplasty, since it can affect early implant loosening and periprosthetic fractures (PPF). This study aimed to investigate how small deviations from the ideal stem size and position influences the PPF risk and primary stability. Six experienced surgeons performed preoperative templating based on which the benchmark size for each femur was determined. Consecutive implantations were performed in six cadaveric femur pairs-one side was implanted with an undersized stem followed by the benchmark size and the contralateral side with a benchmark size followed by an oversized stem (Corail, Depuy Synthes). Moreover, three different alignments (six varus, six neutral, six valgus-undersized) were compared using 18 femurs. Cortical strains during broaching and implantation were measured, and laser scans were used to determine final stem position. All specimens underwent dynamic loading. Primary stability was estimated from stem subsidence and pull-out forces. Templated stem size varied between surgeons (±1 size; p = 0.005). Undersizing increased stem subsidence by 320% (p < 0.001). Oversized stems exhibited 52% higher pull-out forces (p = 0.001) and 240% higher cortical strains (p = 0.056). Cortex strains increased with varus alignment (R2 = 0.356, p = 0.011) while primary stability decreased with valgus stem alignment (p = 0.043). Surgeons should be aware that small deviations from the ideal stem size and malalignments of the stem can significantly alter the mechanical situation and affect the success of their surgery.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Periprosthetic Fractures , Humans , Arthroplasty, Replacement, Hip/adverse effects , Periprosthetic Fractures/etiology , Prosthesis Design , Femur/surgery , Retrospective Studies
3.
BMC Musculoskelet Disord ; 24(1): 914, 2023 Nov 27.
Article in English | MEDLINE | ID: mdl-38012614

ABSTRACT

BACKGROUND: The self-perceived health status of patients undergoing total hip and knee arthroplasty (THA and TKA) might differ post-operatively due to gender, age, or comorbidities. Patient-reported outcome measures (PROMs) such as the EQ-5D-5L measure the self-perceived health status. This study investigates whether the index score of the EQ-5D-5L is a valid tool for interpreting gender differences in outcomes for patients undergoing THA and TKA. METHODS: Routine and PROM-data of elective primary THA or TKA patients in two German hospitals between 2016 and 2018 were analyzed. Univariate analysis with Pearson's chi-square was conducted to identify control variables for gender. To quantify the association between gender and the EQ-5D-5L dimensions, a cumulative odds ordinal logistic regression with proportional odds was conducted. RESULTS: Two thousand three hundred sixty-eight​​ THA patients (m = 978; f = 1390) and 1629 TKA patients (m = 715; f = 914) were considered. The regression analysis of the individual EQ-5D-5L dimensions showed that female gender was significantly associated with better self-care (THA and TKA) and better post-operative mobility (THA). In contrast, male gender was significantly associated with less pain/discomfort (TKA) and less anxiety/depression (THA) pre-surgery and 3-months post-surgery. CONCLUSION: Our results confirmed that the self-perceived health status improved after surgery. However, due to the different associations of gender to the individual dimensions of the EQ-5D-5L, the weighted index score clouds the comparability between patients with different gender undergoing THA or TKA. Therefore, we argue to use the individual five dimensions for health status analysis, to reveal relevant additional information.


Patients undergoing total hip and knee arthroplasty (THA and TKA) can fill out standardized questionnaires pre- and post-surgery, such as the EQ-5D-5L, to measure the improvement in the self-perceived health status. The EQ-5D-5L includes mobility, self-care, usual activity, pain/discomfort, and anxiety/depression. We do not know whether male and female patients experience the same improvement in the dimensions or whether significant differences exist. Currently, only index scores of the EQ-5D-5L are used for the comparison of pre- and post-operative health status. However, due to the questionnaire's weighted composition, relevant changes in individual dimensions might be easily missed. Thus, we investigated whether significant differences between gender and the EQ-5D-5L dimensions in patients undergoing TKA and TKA are observable. We found that female patients reported significantly better scores in self-care (THA and TKA) and post-operative mobility (THA). In contrast, male gender was significantly associated with less pain/discomfort (TKA) and less anxiety/depression (THA) pre-surgery and 3-months post-surgery. The EQ-5D-5L's weighted index score, however, does not directly represent these differences. Therefore, we argue to use the individual five dimensions for health status analysis, as relevant additional information on improvement over time would otherwise be missed.


Subject(s)
Arthroplasty, Replacement, Hip , Arthroplasty, Replacement, Knee , Humans , Male , Female , Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Hip/adverse effects , Quality of Life , Retrospective Studies , Health Status , Surveys and Questionnaires
4.
J Orthop Res ; 41(6): 1283-1290, 2023 06.
Article in English | MEDLINE | ID: mdl-36370133

ABSTRACT

Aseptic loosening is one of the major reasons for re-revisions of cementless revision stems. Insufficient primary stability is associated with bone characteristics and the surgical process. This study aimed to investigate how femur morphology and preparation methods influence the primary stability of revision stems. The Femur morphology was described by the upper femoral curvature (UFC) and an individualized Dorr type classification based on the ratio between the canal-to-calcar ratio (CCR*) and the cortical index (CI*) introduced as the cortical-canal shape (CCS). Manual and powered reaming in combination with helical and straight reamers were used to prepare the bone cavity of 10 cadaveric human femur pairs. Forces during stem impaction were recorded (Reclaim, Depuy Synthes). Micromotion at the bone-implant interface during cyclic axial loading and torsional load to failure was determined. The CCS and impaction forces (R2 = 0.817, p < 0.001) or torsional strength (R2 = 0.577, p < 0.001) are inversely related. CCS did not correlate with micromotion during axial loading (R2 = 0.001, p > 0.999), but proximal femoral curvature did (R2 = 0.462, p = 0.015). Powered reaming and straight reamers led to an improved torsional strength (both: p = 0.043). The Individualized Dorr classification CCS and UFC allows a good estimation of the primary stability of revision stems. For severely curved Dorr type-C femurs, an alternative anchorage method should be considered clinically.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Humans , Arthroplasty, Replacement, Hip/methods , Prosthesis Design , Femur/surgery , Lower Extremity/surgery , Reoperation , Retrospective Studies
5.
J Orthop ; 29: 50-59, 2022.
Article in English | MEDLINE | ID: mdl-35125779

ABSTRACT

PURPOSE: To calculate unstratified and patient-specific meaningful improvement (MI) and patient acceptable symptom states (PASS) for the WOMAC total score in patients after total hip (THR) or total knee replacement (TKR). METHODS: A retrospective observational cohort study. Anchor-based receiver operator characteristics curves were used to estimate MI and PASS thresholds. RESULTS: Recovery paths were specific to individual characteristics of patients. An unstratified 12-months MI threshold of 28.1 (PASS: 13.3) and 17.8 (PASS: 15.8) for patients after THR and TKR, respectively, would unfairly detect critical recovery paths. CONCLUSIONS: Thresholds for treatment success need to be as patient-specific as possible.

6.
Arthroplast Today ; 14: 14-21, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35106353

ABSTRACT

BACKGROUND: The influence of the surgical process on implant loosening and periprosthetic fractures (PPF) as major complications in uncemented total hip arthroplasty (THA) has rarely been studied because of the difficulty in quantification. Meanwhile, registry analyses have clearly shown a decrease in complications with increasing experience. The goal of this study was to determine the extent of variability in THA stem implantation between highly experienced surgeons with respect to implant size, position, press-fit, contact area, primary stability, and the effect of using a powered impaction tool. METHODS: Primary hip stems were implanted in 16 cadaveric femur pairs by three experienced surgeons using manual and powered impaction. Quantitative CTs were taken before and after each process step, and stem tilt, canal-fill-ratio, press-fit, and contact determined. Eleven femur pairs were additionally tested for primary stability under cyclic loading conditions. RESULTS: Manual impactions led to higher variations in press-fit and contact area between the surgeons than powered impactions. Stem tilt and implant sizing varied between surgeons but not between impaction methods. Larger stems exhibited less micromotion than smaller stems. CONCLUSIONS: Larger implants may increase PPF risk, while smaller implants reduce primary stability. The reduced variation for powered impactions indicates that appropriate measures may promote a more standardized process. The variations between these experienced surgeons may represent an acceptable range for this specific stem design. Variability in the implantation process warrants further investigations since certain deviations, for example, a stem tilt toward varus, might increase bone stresses and PPF risk.

7.
Am J Phys Med Rehabil ; 100(10): 972-977, 2021 10 01.
Article in English | MEDLINE | ID: mdl-33443861

ABSTRACT

OBJECTIVE: The aim of the study was to investigate whether patient-specific factors, preoperative patient-reported outcome measures, and participation in a preoperative patient education session significantly predict 1-yr Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) total score and EuroQol 5 Dimensions 5 Levels (EQ-5D-5L) health status index of patients who underwent total hip or knee arthroplasties within an enhanced rehabilitation program. DESIGN: This is a retrospective observational cohort study. The inclusion criteria were met by 676 (373 total hip arthroplasties and 303 total knee arthroplasties) patients. Two multiple regression models were carried out to estimate the contributions of nine potential predictors. RESULTS: Younger age (P = 0.006), higher preoperative EQ-5D-5L index (P = 0.004), lower patient clinical complexity level (P = 0.001), lower preoperative WOMAC total score (P < 0.001), preoperative patient education session (P = 0.004), and submitting for total hip arthroplasty (P < 0.001) were significant predictors of better 1-yr WOMAC total score. Higher preoperative EQ-5D-5L index (P < 0.001), lower patient clinical complexity level classification (P < 0.001), lower preoperative WOMAC total score (P = 0.009), preoperative patient education session (P = 0.04), and submitting for total hip arthroplasty (P = 0.01) were significant predictors of higher 1-yr EQ-5D-5L health status index. CONCLUSIONS: Better baseline patient-reported outcome measure scores, less comorbidities, younger age, submitting for total hip arthroplasty, and attending a preoperative patient education session were significant predictors of better WOMAC total scores and higher EQ-5D-5L health status index 1 yr after total hip or total knee arthroplasties.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Arthroplasty, Replacement, Hip/rehabilitation , Arthroplasty, Replacement, Knee/methods , Arthroplasty, Replacement, Knee/rehabilitation , Patient Education as Topic , Aged , Cohort Studies , Female , Health Status Indicators , Humans , Male , Middle Aged , Patient Reported Outcome Measures , Predictive Value of Tests , Preoperative Period , Retrospective Studies
8.
J Orthop ; 21: 517-522, 2020.
Article in English | MEDLINE | ID: mdl-33013084

ABSTRACT

PURPOSE: To investigate whether WOMAC scores changes after THA or TKA are gender and joint specific. METHODS: Retrospective cohort study. The data of 855 THA and 684 TKA patients were analyzed. RESULTS: Follow-up time (p < 0.001), gender (p < 0.001), joint (p < 0.001), and interaction FU by joint (p < 0.001) had significant effects on WOMAC total and sub-scores. Patients after TKA perceived less improvement in all dimensions in comparison to THA patients (p < 0.001). CONCLUSION: WOMAC score changes after THA or TKA are joint-specific. Patients after TKA perceived less improvement. These results can be used to adjust patients' expectations.

9.
Sensors (Basel) ; 20(8)2020 Apr 15.
Article in English | MEDLINE | ID: mdl-32326616

ABSTRACT

E-rehabilitation is the term used to define medical rehabilitation programs that are implemented at home with the use of information and communication technologies. The aim was to test whether sensor position and the sitting position of the patient influence the accuracy of knee range of movement (ROM) data displayed by the BPMpathway e-rehabilitation system. A preliminary study was conducted in a laboratory setting with healthy adults. Knee ROM data was measured with the BPMpathway e-rehabilitation system and simultaneously with a BIOPAC twin-axis digital goniometer. The main outcome was the root mean squared error (RMSE). A 20% increase or reduction in sitting height led to a RMSE increase. A ventral shift of the BPMpathway sensor by 45° and 90° caused significant measurement errors. A vertical shift was associated with a diminution of the measurement errors. The lowest RMSE (2.4°) was achieved when the sensor was placed below the knee. The knee ROM data measured by the BPMpathway system is comparable to the data of the concurrent system, provided the instructions of the manufacturer are respected concerning the sitting position of the subject for knee exercises, and disregarding the same instructions for sensor positioning, by placing the sensor directly below the knee.


Subject(s)
Arthroplasty, Replacement, Knee/rehabilitation , Rehabilitation/methods , Adult , Healthy Volunteers , Humans , Knee Joint/physiology , Male , Range of Motion, Articular/physiology , Young Adult
10.
Clin Biomech (Bristol, Avon) ; 63: 185-192, 2019 03.
Article in English | MEDLINE | ID: mdl-30913461

ABSTRACT

BACKGROUND: Reaming of the acetabular cavity and cup implantation directly influence the hip rotation center and contact area between implant and bone. Previous studies have reported on an altered rotation center after total hip arthroplasty, but have not studied the influence of reaming and cup implantation separately. Aim of this study was therefore to analyze the individual influence of acetabular reaming and subsequent cup implantation on the rotation center and how this influences the contact conditions at the bone-implant interface. METHODS: Acetabular press-fit cups were implanted into the left and right hips of three full cadavers (n = 6). CT scans were performed to calculate the change in hip rotation center after reaming and prior to liner insertion. 3D models of the cups were used to determine the polar gap, the contact conditions and the effective press-fit. FINDINGS: Reaming the acetabular cavity shifted the rotation center medially (median 5.8 mm, range 4.8-9.1), superiorly (5.3 mm, 3.0-7.0) and posteriorly (2.9 mm, 1.0-5.3). With cup implantation, the rotation center shifted back towards the native position, but no full restoration was observed. The degree of shift increased with the size of polar gap (rs = 0.829, P = .042), which inversely reduced the contact area (rs = 0.886, P = .019). INTERPRETATION: This study reveals that the dominant factor in hip rotation center restoration is the reaming process, while the cup implantation for a given nominal press-fit has only a small influence. Increasing the press-fit would improve the restoration but bares the danger of insufficient bone coverage and periprosthetic fractures due to the high forces needed.


Subject(s)
Acetabulum/surgery , Arthroplasty, Replacement, Hip/instrumentation , Hip Prosthesis , Prosthesis Design , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip/methods , Cadaver , Female , Humans , Male , Middle Aged , Orthopedics , Rotation , Tomography, X-Ray Computed
11.
J Orthop Res ; 37(7): 1580-1589, 2019 07.
Article in English | MEDLINE | ID: mdl-30908684

ABSTRACT

Implant loosening and periprosthetic fracture are two major revision causes for uncemented hip stems. The chosen method of cavity preparation could play a key role for both failure mechanisms. The aim of this study was to determine the dependence of the broach type as well as patient bone mineral density (BMD) on densification and contact conditions at the bone-implant interface. Hip stems were implanted into cadaveric femora using compaction, blunt extraction or sharp extraction broaches with computed tomography scans performed prior to broaching, after broaching and after stem implantation. Proximal periprosthetic bone densification as well as press-fit, contact area and stem seating relative to the last broach were determined. Median bone densification was higher with the compaction and blunt extraction broaches compared to sharp extraction broaches (181% and 177%, respectively, p = 0.002). The bone densification of femora prepared with compaction broaching increased with higher BMD (R2 = 0.183, p = 0.037), while stem seating decreased with higher BMD for all broach types (R2 = 0.259, p = 0.001). Incomplete seated prostheses were associated with smaller press-fit and bone-implant contact area (R2 = 0.249, p = 0.001; R2 = 0.287, p < 0.001). Clinical Significance: The results suggest that compaction broaching maximizes bone densification in patients with higher bone density. However, there appears to be an increased risk of insufficient stem seating in high-density bone that could limit the benefits for primary stability. For lower quality bone, the broach type appears to play a lesser role, but care must be taken to limit extensive stem seating which might increase periprosthetic fracture risk. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 37:1580-1589, 2019.


Subject(s)
Arthroplasty, Replacement, Hip/instrumentation , Adult , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip/methods , Bone Density , Hip Prosthesis , Humans , Middle Aged
12.
Open Orthop J ; 12: 364-372, 2018.
Article in English | MEDLINE | ID: mdl-30288191

ABSTRACT

BACKGROUND: The question whether Pelvic Tilt (PT) angles measured in the supine position are adequate for the alignment of the acetabular cup without an adjustment for anatomical differences between patients is of clinical importance. The aim of this work was to test for factors that can significantly affect PT angles. METHODS: In the present retrospective cohort comparison, the PT angles of 12 Symptom-Free Young Subjects (SFYS) and 45 patients scheduled for Total Hip Arthroplasty (THA) were compared. The data was collected during two studies with the use of a novel smartphone-based navigated ultrasound measurement system. Multi-factorial analysis of variance was run to determine which factors significantly affect PT. RESULTS: Body position (F= 126.65; P< 0.001) and group (SFYS vs. THA patients) (F= 17.52; P< 0.001) had significant main effects on PT. There was also a significant interaction between body position and group (F= 25.59; P< 0.001). The mean PT increased by 8.1° from an interiorly to a neutral tilted position (P< 0.001) and 21.4° from a neutral to a posteriorly tilted position (P< 0.001) with the transition from the supine into the upright position for the SFYS and THA patients, respectively. CONCLUSION: In both groups, PT changed significantly with a transition from the supine to the upright position. A position-dependent mean PT increase in the patient group showed that acetabular cup alignment based on PT in the supine position is not reliable without taking into consideration the inclination of the pelvis in standing position. This may lead to instability and dislocations.

13.
J Ultrasound Med ; 37(10): 2333-2342, 2018 Oct.
Article in English | MEDLINE | ID: mdl-29480567

ABSTRACT

OBJECTIVES: Pelvic tilt is the angle between the anterior pelvic plane and the coronal plane. It affects cup positioning in total hip arthroplasty. The primary objective of this study was to test the intra- and inter-rater reliability of a navigated smart device-based ultrasound system for pelvic tilt assessment. The secondary objective was to test the inter-rater variability of the measurements on a hip phantom. METHODS: A repeated-measures design was used. Two raters measured the pelvic tilt of 12 symptom-free young adults in upright and supine positions. Additionally, pelvic tilt was measured on a hip phantom. Each rater performed 3 measurements in each body position on the participants and 12 measurements on the hip phantom. Intra- and inter-rater reliability were calculated with the use of intraclass correlation coefficients. The variability in measurements on the hip phantom was assessed by a Bland-Altman analysis of agreement. RESULTS: Intraclass correlation coefficient 95% confidence intervals for intra-rater reliability ranged from good to excellent and moderate to excellent for the supine and upright positions respectively. Intraclass correlation coefficient 95% confidence intervals for inter-rater reliability ranged from poor to excellent for both positions. Hip phantom measurements showed no significant average bias (P > .05) and no significant proportional bias (P > .05). The 95% inter-rater limits of agreement were ±1.3° and ±1.7° for the supine and upright positions, respectively. CONCLUSIONS: The intra-rater reliability values achieved were suitable. Intraclass correlation coefficient values for inter-rater reliability remained below an acceptable level. Possible reasons and overcoming strategies were presented. The 95% limits of agreement were good, at less than ±2°.


Subject(s)
Pelvis/anatomy & histology , Ultrasonography/methods , Adult , Female , Humans , Male , Observer Variation , Phantoms, Imaging , Posture , Prospective Studies , Reference Values , Reproducibility of Results , Young Adult
14.
Knee Surg Sports Traumatol Arthrosc ; 26(9): 2788-2796, 2018 Sep.
Article in English | MEDLINE | ID: mdl-29071356

ABSTRACT

PURPOSE AND HYPOTHESIS: Patient-specific instrumentation (PSI) uses 3D preoperative imaging to produce individualized cutting blocks specific to patients' anatomy and according to the preoperative plan with the aim to reduce the number of mechanical leg alignment (MLA) outliers, to improve implant positioning and to decrease surgery time. The primary purpose of this study was to investigate the efficacy of a specific PSI in comparison with standard instrumentation (SI) in reducing the number of MLA outliers. It was hypothesized that the number of MLA outliers would be significantly lower in the PSI group. METHODS: A multicenter randomized controlled trial was implemented. There were 59 patients in the PSI group and 66 in the SI group. The absolute number of outliers outside the ± 3° target neutral MLA was compared between the groups with a Chi-square test. As secondary outcomes, the Knee Society Score (KSS) and the Knee Injury and Osteoarthritis Outcome Score (KOOS) were compared between the groups preoperatively and at 90-day follow-up. RESULTS: There were 15 (26.3%) MLA outliers in the PSI group and 8 (12.3%) in the SI group. The number of outliers was not independent from the group ( X2 (1) = 3.8, p = 0.04; Relative risk = 1.5). Preoperatively, there were no significant differences between the groups when comparing their KSS and KOOS sub-scores. At 90 days postoperatively, the patients in the SI group showed better KOOS-Quality of Life (KOSS-QOL) in comparison with the PSI group (p < 0.0001). CONCLUSION: The use of PSI did not significantly reduce the number of MLA outliers in comparison with SI. There were no differences when comparing the achieved mean MLA of both groups. LEVEL OF EVIDENCE: Level I, prospective randomized controlled trial.


Subject(s)
Arthroplasty, Replacement, Knee/methods , Imaging, Three-Dimensional , Knee/surgery , Surgery, Computer-Assisted/methods , Aged , Female , Humans , Knee Prosthesis , Male , Middle Aged , Operative Time , Postoperative Period , Prospective Studies , Quality of Life , Treatment Outcome
15.
Clin Biomech (Bristol, Avon) ; 46: 1-5, 2017 Jul.
Article in English | MEDLINE | ID: mdl-28463695

ABSTRACT

BACKGROUND: The strength of the modular fixation between head and stem taper of total hip replacement implants should be sufficient to minimise relative motion and prevent corrosion at the interface. Intraoperatively the components are assembled by impaction with a hammer. It is unclear whether the effective compliance of the patient's body modifies the strength of the taper interface under impaction assembly. The purpose of this study was to assess the influence of the compliance of the patient's body on the taper fixation strength. METHODS: Cobalt-chrome and ceramic femoral heads were assembled with titanium alloy stem tapers in the laboratory under impaction. Impaction forces were applied with a constant energy, defined by the drop height of the impactor, according to standard experimental procedure. The compliance of the patient was simulated in the laboratory by varying the stiffness of springs mounted below the stem taper. Pull-off forces between head and neck were measured to determine fixation strength. FINDINGS: Decreasing spring stiffness had no effect on the applied peak impaction forces during assembly or on the pull-off forces. Pull-off forces showed no difference between metal and ceramic head materials. INTERPRETATION: Pull-off forces and impaction forces were independent of the spring stiffness below the stem taper, indicating that the compliance of the patient has no effect on the taper fixation strength. Impaction testing in the laboratory can therefore be performed under rigid fixation, without accounting for the compliance of the patient.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Femur Head/surgery , Hip Prosthesis , Ceramics , Chromium Alloys , Computer Simulation , Humans , Mechanical Phenomena , Models, Theoretical , Motion , Prosthesis Design , Stress, Mechanical , Titanium
16.
Integr Med (Encinitas) ; 15(3): 20-4, 2016 Jun.
Article in English | MEDLINE | ID: mdl-27547162

ABSTRACT

The use of safe and beneficial dietary supplements remains an important part of your patients' healthy lifestyle-and supplements are likely an important part of your integrative medicine practice. Although issues surrounding potency, ingredient identification, adulteration, and the enforcement of existing laws are legitimate concerns for medical professionals and consumers, the responsible industry is actively working to raise quality standards for its products through a number of self-regulatory measures. These include education about and adoption of additional quality assurance initiatives, such as GMPs for botanical ingredients; better supply-chain management; adoption of improved identification and testing methodologies; an industry-wide product registry; the use of accredited third-party certifications and seals; and initiatives to promote widespread membership in the industry's trade associations, which is a reliable indicator of a company's support of and adherence to strict quality guidelines. Also, industry support of appropriate enforcement actions against problem players and products from the US Food and Drug Administration (FDA), the Federal Trade Commission (FTC), and states' attorneys general continues in an effort to rid the market of unsafe and mislabeled products.

17.
Orthopedics ; 39(3 Suppl): S6-S12, 2016 May.
Article in English | MEDLINE | ID: mdl-27219731

ABSTRACT

Some surgically modifiable factors are related to soft tissue balance. With computer-assisted surgery, it is possible to access these variables quantitatively. The aim of this analysis was to study the influence of gap balance on clinical outcomes within the first year after computer-navigated total knee arthroplasty (TKA). Based on navigation data, 3 independent variables reflecting gap balance were used to split the patients in 2 groups. The Knee Society Scores (Function [KSS-F] and Knee [KSS-K]) and the maximal knee flexion (MKF) measured preoperatively and at 3, 6 and 12 months were compared using analyses of variance (2×4 design) for repeated measures. Higher flexion-extension gap equality led to statistically higher KSS-F and KSS-K scores at 1 year (P=.02). Higher medial-lateral flexion gap equality led to superior mean MKF at all measurement points; however the differences were statistically only significant at 3 months (P=.01). The coefficients of variation of the variables used to select the patients were overall very low. With computer-assisted navigation, it is possible to access quantitatively the size of the medial and lateral flexion and extension gaps. Higher flexion-extension gap equality values led to statistically significant better KSS-F and KSS-K scores at 1 year. Higher medial-lateral flexion gap equality values led to better MKF values; however the differences were only statistically significant at 3 months. [Orthopedics. 2016; 39(3):S6-S12.].


Subject(s)
Arthroplasty, Replacement, Knee/methods , Joint Diseases/surgery , Knee Joint/surgery , Surgery, Computer-Assisted , Aged , Female , Humans , Male , Middle Aged , Randomized Controlled Trials as Topic , Range of Motion, Articular , Treatment Outcome
18.
Knee Surg Sports Traumatol Arthrosc ; 24(11): 3457-3465, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27129369

ABSTRACT

PURPOSE: There are multiple factors affecting maximal knee flexion (MKF) after total knee arthroplasty (TKA). The aim of the study was to investigate whether patient-specific factors (PSF) and surgically modifiable factors (SMF), measured by means of a computer-assisted navigation system, can predict the MKF after TKA. METHODS: Data from 99 patients collected during a randomized clinical trial were used for this secondary data analysis. The MKF of the patients was measured preoperatively and 1-year post-surgery. Multiple regression analyses were performed to investigate which combination of variables would be the best to predict the 1-year MKF. RESULTS: When considering SMF alone, the combination of three factors significantly predicted the 1-year MKF (p = 0.001), explaining 22 % of its variation. When considering only PSF, the combination of pre-op MKF and BMI significantly predicted the 1-year MKF (p < 0.001), explaining 23 % of its variation. When considering both groups of potential predictors simultaneously, the combination of five SMF with two PSF significantly predicted the 1-year MKF (p = 0.001), explaining 32 % of its variation. CONCLUSIONS: Computer navigation variables alone could explain 22 % of the variance in the 1-year MKF. The larger proportion (32 %) of the 1-year MKF variation could be explained with a combination of SMF and PSF. The results of studies in this area could be used to identify patients at risk of poor outcomes. LEVEL OF EVIDENCE: Level II, Prognostic study.


Subject(s)
Arthroplasty, Replacement, Knee , Range of Motion, Articular/physiology , Surgery, Computer-Assisted , Aged , Female , Follow-Up Studies , Humans , Knee Joint/surgery , Male , Middle Aged , Osteoarthritis, Knee/surgery
19.
BMC Musculoskelet Disord ; 17: 78, 2016 Feb 13.
Article in English | MEDLINE | ID: mdl-26873695

ABSTRACT

BACKGROUND: The purpose was to investigate whether patient-specific factors (PSF) and surgically modifiable factors (SMF), measured by means of a computer-assisted navigation system, can predict the Knee Society Scores (KSS) after total knee arthroplasty (TKA). METHODS: Data from 99 patients collected during a randomized clinical trial were used for this secondary data analysis. The KSS scores of the patients were measured preoperatively and at 4-years follow-up. Multiple regression analyses were performed to investigate which combination of variables would be the best to predict the 4-years KSS scores. RESULTS: When considering SMF alone the combination of four of them significantly predicted the 4-years KSS-F score (p = 0.009), explaining 18 % of its variation. When considering only PSF the combination of age and body weight significantly predicted the 4-years KSS-F (p = 0.008), explaining 11 % of its variation. When considering both groups of predictors simultaneously the combination of three PSF and two SMF significantly predicted the 4-years KSS-F (p = 0.007), explaining 20 % of its variation. CONCLUSIONS: Younger age, better preoperative KSS-F scores and lower BMI before surgery, a positive tibial component slope and small changes in femoral offset were predictors of better KSS-F scores at 4-years.


Subject(s)
Arthroplasty, Replacement, Knee , Decision Support Techniques , Knee Joint/surgery , Osteoarthritis, Knee/surgery , Surgery, Computer-Assisted , Age Factors , Aged , Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Knee/instrumentation , Biomechanical Phenomena , Body Mass Index , Female , Germany , Humans , Knee Joint/physiopathology , Knee Prosthesis , Male , Middle Aged , Osteoarthritis, Knee/diagnosis , Osteoarthritis, Knee/physiopathology , Predictive Value of Tests , Recovery of Function , Risk Factors , Surgery, Computer-Assisted/adverse effects , Surgery, Computer-Assisted/instrumentation , Time Factors , Treatment Outcome
20.
Knee Surg Sports Traumatol Arthrosc ; 23(6): 1660-8, 2015 Jun.
Article in English | MEDLINE | ID: mdl-24929659

ABSTRACT

PURPOSE: The theoretical advantages of mobile-bearing (MB) designs over the conventional fixed bearings (FBs) for total knee arthroplasty (TKA) have not been proved yet through clinical studies. The aim of the study was to test whether the MB design has advantages in terms of better clinical outcomes when compared to FB. Furthermore, the relationships between intra-operative obtained implant positioning data and the clinical scores were analysed. METHODS: A total of 99 patients were randomized into the FB or the MB group. All patients received the same posterior cruciate retaining implants and were operated with the use of a computer-assisted navigation system. The clinical outcomes of both groups were compared pre-operatively, at 1 year, and at a mean follow-up time of 4 years after surgery. RESULTS: The MB implants showed no advantages over the FB when comparing the Knee Society Scores, the Oxford Score, the range of movement (ROM) and pain intensity of the patients in both groups at 1 and 4 years after surgery. There were no relationships between the computer navigation data and the clinical scores. CONCLUSIONS: In view of the 4-year results, there is no evidence to support the recommendation of one design over the other in terms of better clinical outcome scores, higher ROM or lower pain rates. Long-term follow-up results may be necessary, including survival rates. Further research comparing different TKA designs should also include standardized performance-based tests. LEVEL OF EVIDENCE: Prospective study (Randomized controlled trial with adequate statistical power to detect differences), Level I.


Subject(s)
Arthroplasty, Replacement, Knee/instrumentation , Knee Prosthesis , Prosthesis Design , Surgery, Computer-Assisted , Aged , Arthroplasty, Replacement, Knee/methods , Female , Humans , Male , Pain Measurement , Patient Outcome Assessment , Prospective Studies , Range of Motion, Articular
SELECTION OF CITATIONS