1.
Opt Eng ; 58(5)2019.
Article in English | MEDLINE | ID: mdl-34531618

ABSTRACT

We describe the design and ground-based performance of the two-color calibration lamp for the Michelson Interferometer for Global High-Resolution Thermospheric Imaging (MIGHTI) instrument on the NASA Ionospheric Connection (ICON) satellite. The calibration lamp assembly contains radio frequency excited krypton and neon lamps, which generate emission lines at 557 and 630 nm, respectively, and which are used to monitor thermal drifts in the two MIGHTI Doppler asymmetric spatial heterodyne interferometers. The lamps are coupled to two mixed optical fiber bundles that deliver the calibration signals to the two MIGHTI optical units. The assembly starts reliably, consumes <8 W, and has passed environmental testing for the ICON satellite. The total mass of the lamp assembly is 1.8 kg. Special features of the assembly and its implementation are described along with results of life tests.

SELECTION OF CITATIONS
SEARCH DETAIL
...