Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Horm Metab Res ; 56(2): 111-117, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38049146

ABSTRACT

The coronavirus disease 2019 (COVID-19) pandemic caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has led to the development of various vaccines. Reports have emerged suggesting a possible association between SARS-CoV-2 vaccination and the onset of thyroid diseases. This review explores the clinical aspects of thyroid disorders following SARS-CoV-2 vaccination, including a case report of a patient with concomitant subacute thyroiditis (SAT) and Graves' disease (GD) with blocking thyrotropin receptor autoantibodies (TSH-R-Ab) following SARS-CoV-2 vaccination. SAT, characterized by transient inflammation of the thyroid gland, has been reported after SARS-CoV-2 vaccination. GD, an autoimmune hyperthyroidism, has also been observed post-vaccination, often with stimulating TSH-R-Ab. Graves' orbitopathy (GO) has been associated with SARS-CoV-2 vaccination in patients with a history of immune thyroid disease. The unique case underscores a very rare thyroid condition of functional hypothyroidism in possible relation to SARS-CoV-2 vaccination and the usefulness of functional analysis of TSH-R-Ab that can provide valuable insights into disease pathogenesis and help to guide treatment. This review highlights the need for continued monitoring and awareness of potential thyroid-related complications following SARS-CoV-2 vaccination.


Subject(s)
COVID-19 , Graves Disease , Graves Ophthalmopathy , Thyroiditis, Subacute , Humans , Pandemics , Graves Ophthalmopathy/complications , COVID-19 Vaccines , Receptors, Thyrotropin , Autoantibodies/analysis , COVID-19/complications , SARS-CoV-2 , Inflammation/complications , Thyrotropin
2.
J Cardiovasc Electrophysiol ; 34(5): 1241-1248, 2023 05.
Article in English | MEDLINE | ID: mdl-37061886

ABSTRACT

BACKGROUND: The role of triggers in the occurrence of appropriate implantable cardioverter-defibrillator (ICD) shocks due to ventricular tachyarrhythmias is not well known. The aim of the study was to assess the prevalence of trigger factors in appropriate ICD shocks and to analyze their prognostic impact on clinical outcome. METHODS: A total of 710 consecutive patients of a prospective single-center ICD-registry who received a first appropriate ICD shock between 2000 and 9/2021 were analyzed. RESULTS: In 35% of ICD patients with first ICD shock, at least one of the following triggers was found: Ischemia (22%), Compliance (9%), Decompensation (38%), Stress (12%), Technical (5%), Electrolyte/endocrinological disorder (22%) and Medication side effects (4%). The trigger factors can be summarized under the acronym ICD-STEMi. The prospective application of the ICD-STEMi scheme increased the rate of identified triggers from 32% to 56% (p < .001). Patients with triggered first ICD shock had an increased 5-year mortality rate (50% vs. 38%, p < .001). Patients with triggers did not show different mortality outcomes or recurrent ICD shocks whether they received arrhythmia therapy or not. CONCLUSIONS: The evaluation of trigger factors after the occurrence of ICD shocks is mandatory and can be systematically evaluated using the acronym ICD-STEMi. Systematic evaluation of triggers using the ICD-STEMi scheme can identify triggers in about half of ICD patients with first appropriate ICD shock. Patients with triggered ICD shock have a 12% higher 5-year mortality rate.


Subject(s)
Defibrillators, Implantable , ST Elevation Myocardial Infarction , Tachycardia, Ventricular , Humans , Prognosis , Defibrillators, Implantable/adverse effects , Arrhythmias, Cardiac/therapy , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/therapy , Risk Factors
4.
Clin Cardiol ; 42(10): 866-872, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31317573

ABSTRACT

BACKGROUND: Implantable cardioverter defibrillator (ICD) was implemented into clinical routine more than 20 years ago. Since then, ICD therapy became standard therapy for primary and secondary prevention of sudden cardiac death in clinical practice. OBJECTIVES: Aim of the study was to evaluate the benefit-harm profile of contemporary primary prophylactic ICD therapy. METHODS: A total of 1222 consecutive patients of a prospective single-center ICD-registry were analyzed who underwent primary prophylactic ICD implantation between 2000 and 2017. Patients were divided into two groups according to the implantation year: 2010-2017 (group 1, n = 579) and 2000-2009 (group 2, n = 643). RESULTS: The rate of estimated appropriate ICD therapy after 8 years was 51% in the 2000s and 42% in the 2010s (P < .001). The complication rate changed slightly from 53% to 47% (P = .005). This decline was mainly driven by the reduction of inappropriate ICD shocks (30% vs 14%, P < .001) whereas the rate of ICD shock lead malfunction and device/ lead infection remained unchanged over time. Nonischemic cardiomyopathy was an independent predictor for ICD complications without benefit of ICD therapy (HR 1.37, 95% CI 1.07-1.77). CONCLUSION: The ICD therapy rate for ventricular arrhythmias in patients with primary prophylactic ICD implantation is decreasing over the last two decades. Complication rate remains high due to an unchanged rate of ICD shock malfunctions and device infections. Nonischemic cardiomyopathy is an independent predictor for ICD complications without benefit of ICD therapy in primary prophylactic ICD-therapy.


Subject(s)
Arrhythmias, Cardiac/therapy , Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable , Primary Prevention/methods , Registries , Risk Assessment/methods , Arrhythmias, Cardiac/complications , Arrhythmias, Cardiac/mortality , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Female , Follow-Up Studies , Germany/epidemiology , Humans , Incidence , Male , Middle Aged , Prospective Studies , Risk Factors , Survival Rate/trends , Time Factors , Treatment Outcome
SELECTION OF CITATIONS