1.
Int Wound J ; 13(5): 619-24, 2016 Oct.
Article in English | MEDLINE | ID: mdl-25124729

ABSTRACT

The aim of this study was to assess the reliability of measurements using a wound-analysing tool and their interpretability. Wound surface areas and tissue types, such as granulation, slough and necrosis, in twenty digital photographs were measured using a specific software program. The ratio of these tissue types in a wound was calculated using a wound profile. We calculated the intraclass coefficient or κ for reliability, standard error of measurement (SEM) and smallest detectable change (SDC). The inter-rater reliability intraclass correlation coefficient (ICC) was 0·99 for surface area, 0·76 for granulation, 0·67 for slough and 0·22 for necrosis. The profiles gave an overall κ of 0·16. For test-retest reliability, the ICC was 0·99 for surface area, 0·81 for granulation, 0·80 for slough and 0·97 for necrosis. The agreement of the applied profiles in the test-retest was 66% (40-100). SEM and SDC for surface area were 0·10/0·27; for granulation, 6·88/19·08; for slough, 7·17/19·87; and for necrosis, 0·35/0·98, respectively. Measuring wound surface area and tissue types by means of digital photo analysis is a reliable and applicable method for monitoring wound healing in acute wounds in daily practice as well as in research.


Subject(s)
Wound Healing , Humans , Necrosis , Photography , Reproducibility of Results