Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Beilstein J Nanotechnol ; 15: 279-296, 2024.
Article in English | MEDLINE | ID: mdl-38476324

ABSTRACT

Raman spectroscopy is a widely used technique to characterize nanomaterials because of its convenience, non-destructiveness, and sensitivity to materials change. The primary purpose of this work is to determine via Raman spectroscopy the average thickness of MoS2 thin films synthesized by direct liquid injection pulsed-pressure chemical vapor deposition (DLI-PP-CVD). Such samples are constituted of nanoflakes (with a lateral size of typically 50 nm, i.e., well below the laser spot size), with possibly a distribution of thicknesses and twist angles between stacked layers. As an essential preliminary, we first reassess the applicability of different Raman criteria to determine the thicknesses (or layer number, N) of MoS2 flakes from measurements performed on reference samples, namely well-characterized mechanically exfoliated or standard chemical vapor deposition MoS2 large flakes deposited on 90 ± 6 nm SiO2 on Si substrates. Then, we discuss the applicability of the same criteria for significantly different DLI-PP-CVD MoS2 samples with average thicknesses ranging from sub-monolayer up to three layers. Finally, an original procedure based on the measurement of the intensity of the layer breathing modes is proposed to evaluate the surface coverage for each N (i.e., the ratio between the surface covered by exactly N layers and the total surface) in DLI-PP-CVD MoS2 samples.

2.
Phys Chem Chem Phys ; 19(24): 15833-15841, 2017 Jun 21.
Article in English | MEDLINE | ID: mdl-28585655

ABSTRACT

Silicon carbide (SiC) sublimation is the most promising option to achieve transfer-free graphene at the wafer-scale. We investigated the initial growth stages from the buffer layer to monolayer graphene on SiC(0001) as a function of annealing temperature at low argon pressure (10 mbar). A buffer layer, fully covering the SiC substrate, forms when the substrate is annealed at 1600 °C. Graphene formation starts from the step edges of the SiC substrate at higher temperature (1700 °C). The spatial homogeneity of the monolayer graphene was observed at 1750 °C, as characterized by Raman spectroscopy and magneto-transport. Raman spectroscopy mapping indicated an AG-graphene/AG-HOPG ratio of around 3.3%, which is very close to the experimental value reported for a graphene monolayer. Transport measurements from room temperature down to 1.7 K indicated slightly p-doped samples (p ≃ 1010 cm-2) and confirmed both continuity and thickness of the monolayer graphene film. Successive growth processes have confirmed the reproducibility and homogeneity of these monolayer films.

3.
Environ Toxicol ; 26(2): 136-45, 2011 Apr.
Article in English | MEDLINE | ID: mdl-20014232

ABSTRACT

Considering the important production of carbon nanotubes (CNTs), it is likely that some of them will contaminate the environment during each step of their life cycle. Nevertheless, there is little known about their potential ecotoxicity. Consequently, the impact of CNTs on the environment must be taken into consideration. This work evaluates the potential impact of well characterized double-walled carbon nanotubes (DWNTs) in the amphibian larvae Xenopus laevis under normalized laboratory conditions according to the International Standard micronucleus assay ISO 21427-1:2006 for 12 days of half-static exposure to 0.1-1-10 and 50 mg L(-1) of DWNTs in water. Two different endpoints were carried out: (i) toxicity (mortality and growth of larvae) and (ii) genotoxicity (induction of micronucleated erythrocytes). Moreover, intestine of larvae were analyzed using Raman spectroscopy. The DWNTs synthetized by catalytic chemical vapor deposition (CCVD) were used as produce (experiment I) and the addition of Gum Arabic (GA) was investigated to improve the stability of the aqueous suspensions (experiment II). The results show growth inhibition in larvae exposed to 10 and 50 mg L(-1) of DWNTs with or without GA. No genotoxicity was evidenced in erythrocytes of larvae exposed to DWNTs, except to 1 mg L(-1) of DWNTs with GA suggesting its potential effect in association with DWNTs at the first nonacutely toxic concentration. The Raman analysis confirmed the presence of DWNTs into the lumen of intestine but not in intestinal tissues and cells, nor in the circulating blood of exposed larvae.


Subject(s)
Micronucleus Tests/methods , Mutagens/toxicity , Nanotubes, Carbon/toxicity , Water Pollutants, Chemical/toxicity , Xenopus laevis/physiology , Animals , Female , International Agencies , Larva/drug effects , Larva/growth & development , Male , Micronucleus Tests/standards , Mutagens/standards , Nanotubes, Carbon/standards , Reference Standards , Spectrum Analysis, Raman , Water Pollutants, Chemical/standards , Xenopus laevis/growth & development
4.
Nanomedicine (Lond) ; 5(6): 963-74, 2010 Aug.
Article in English | MEDLINE | ID: mdl-20735230

ABSTRACT

The potential impact of industrial multiwalled carbon nanotubes (MWNTs) was investigated under normalized laboratory conditions according to the International Standard micronucleus assay ISO 21427-1 for 12 days of half-static exposure to 0.1, 1, 10 and 50 mg/l of MWNTs in water. Three different end points were carried out for 12 days of exposure: mortality, growth inhibition and micronuclei induction in erythrocytes of the circulating blood of larvae. Raman spectroscopy analysis was used to study the presence of carbon nanotubes in the biological samples. Considering the high diversity of carbon nanotubes according to their different characteristics, MWNTs were analyzed in Xenopus larvae, comparatively to double-walled carbon nanotubes used in a previous study in similar conditions. Growth inhibition in larvae exposed to 50 mg/l of MWNTs was evidenced; however, no genetoxicity (micronucleus assay) was noticed, at any concentration. Carbon nanotube localization in the larvae leads to different possible hypothesis of mechanisms explaining toxicity in Xenopus.


Subject(s)
Amphibians/physiology , Nanotubes, Carbon , Animals
5.
Aquat Toxicol ; 87(2): 127-37, 2008 Apr 28.
Article in English | MEDLINE | ID: mdl-18313771

ABSTRACT

Because of their outstanding properties, carbon nanotubes (CNTs) are being assessed for inclusion in many manufactured products. Due to their massive production and growing number of potential applications, the impact of CNTs on the environment must be taken into consideration. The present investigation evaluates the ecotoxicological potential of double-walled carbon nanotubes (DWNTs) in the amphibian larvae Xenopus laevis at a large range of concentrations in water (from 10 to 500 mgL(-1)). Acute toxicity and genotoxicity were analysed after 12 days of static exposure in laboratory conditions. Acute toxicity was evaluated according to the mortality and the growth of larvae. The genotoxic effects were analysed by scoring the micronucleated erythrocytes of the circulating blood of larvae according to the International Standard micronucleus assay. Moreover, histological preparations of larval intestine were prepared after 12 days of exposure for observation using optical and transmission electron microscopy (TEM). Finally, the intestine of an exposed larva was prepared on a slide for analyse by Raman imaging. The results showed no genotoxicity in erythrocytes of larvae exposed to DWNTs in water, but acute toxicity at every concentration of DWNTs studied which was related to physical blockage of the gills and/or digestive tract. Indeed, black masses suggesting the presence of CNTs were observed inside the intestine using optical microscopy and TEM, and confirmed by Raman spectroscopy analysis. Assessing the risks of CNTs requires better understanding, especially including mechanistic and environmental investigations.


Subject(s)
Nanotubes, Carbon/toxicity , Water Pollutants, Chemical/toxicity , Xenopus laevis/physiology , Animals , Larva/drug effects , Microscopy, Electron, Transmission , Mutagenicity Tests , Spectrum Analysis, Raman , Toxicity Tests, Acute , Xenopus laevis/growth & development
SELECTION OF CITATIONS
SEARCH DETAIL
...