Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Small ; : e2311840, 2024 Mar 12.
Article in English | MEDLINE | ID: mdl-38470189

ABSTRACT

With the recently-booming hydrogen (H2 ) economy by green H2 as the energy carriers and the newly-emerged exhaled diagnosis by human organ-metabolized H2 as a biomarker, H2 sensing is simultaneously required with fast response, low detection limit, and tolerant stability against humidity, switching, and poisoning. Here, reliable H2 sensing has been developed by utilizing indium oxide nanocubes decorated with palladium and gold nanodots (Pd-Au NDs/In2 O3 NCBs), which have been synthesized by combined hydrothermal reaction, annealing, and chemical bath deposition. As-prepared Pd-Au NDs/In2 O3 NCBs are observed with surface-enriched NDs and nanopores. Beneficially, Pd-Au NDs/In2 O3 NCBs show 300 ppb-low detection limit, 5 s-fast response to 500 ppm H2 , 75%RH-high humidity tolerance, and 56 days-long stability at 280 °C. Further, Pd-Au NDs/In2 O3 NCBs show excellent stability against switching sensing response, and are tolerant to H2 S poisoning even being exposed to 10 ppm H2 S at 280 °C. Such excellent H2 sensing may be attributed to the synergistic effect of the boosted Pd-Au NDs' spillover effect and interfacial electron transfer, increased adsorption sites over the porous NCBs' surface, and utilized Pd NDs' affinity with H2 and H2 S. Practically, Pd-Au NDs/In2 O3 NCBs are integrated into the H2 sensing device, which can reliably communicate with a smartphone.

2.
Small ; 19(28): e2208026, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37013451

ABSTRACT

Hydrogen (H2 ) sensing materials such as semiconductor metal oxides may suffer from poor long-term stability against humidity and unsatisfactory selectivity against other interfering gases. To address the above issues, highly stable and selective H2 sensing built with palladium oxide nanodots decorating aluminum oxide nanosheets (PdO NDs//Al2 O3 NSs) has been achieved via combined template synthesis, photochemical deposition, and oxidation. Typically, the PdO NDs//Al2 O3 NSs are observed with thin NSs (≈17 nm thick) decorated with nanodots (≈3.3 nm in diameter). Beneficially, the sensor prototypes built with PdO NDs//Al2 O3 NSs show excellent long-term stability for 278 days, high selectivity against interfering gases, and outstanding stability against humidity at 300 °C. Remarkably, the sensor prototypes enable detection of a wide-range of 20 ppm - 6 V/V% H2 , and the response and recovery times are ≈5 and 16 s to 1 V/V% H2 , respectively. Theoretically, the heterojunctions of PdO NDs-Al2 O3 NSs with a large specific surface ratio and Al2 O3 NSs as the support exhibit excellent stability and selective H2 sensing. Practically, a sensing device integrated with the PdO NDs//Al2 O3 NSs sensor prototype is simulated for detecting H2 with reliable sensing response.

3.
Dis Markers ; 2022: 9204119, 2022.
Article in English | MEDLINE | ID: mdl-36277976

ABSTRACT

Objective: To study the regional cerebral blood flow (rCBF) in important brain functional areas and the metabolic levels of these brain functional areas in patients with primary hypothyroidism by using arterial spin labeling (ASL) and magnetic resonance spectroscopy (MRS) techniques to explain the possible causes of brain dysfunction in patients with primary hypothyroidism. Methods: Twenty-five patients with primary hypothyroidism (newly diagnosed and not treated) who were treated in the endocrinology department of our hospital were selected as the research group, and 25 healthy patients with normal thyroid function who came to our hospital during the same period with matched gender and age were selected as the control group. ASL and MRS techniques were used to detect and calculate regional cerebral blood flow (rCBF) in the frontal lobe, hippocampus, and posterior cingulate gyrus, as well as N-acetylaspartate/creatine (NAA/Cr), choline/creatine (Cho) in the brain/Cr, and inositol/creatine (mI/Cr) ratio. The correlations between metabolite ratios measured by rCBF, MRS, and serum TSH, FT3, and FT4 levels were analyzed. Results: Compared with the control group, the rCBF in the frontal lobe, hippocampus, and posterior cingulate gyrus of the dominant hemisphere of the hypothyroid patients in the study group decreased significantly (P < 0.05). The comparison of metabolite ratios showed that compared with the control group, the NAA/Cr ratio of the frontal lobe and posterior cingulate gyrus of the study group was significantly decreased, and the Cho/Cr ratio of the posterior cingulate gyrus of the study group was significantly increased. The MI/Cr ratio of the hippocampus was significantly decreased (all P values < 0.05). Correlation analysis showed that rCBF and NAA/Cr in posterior cingulate gyrus were significantly negatively correlated with serum TSH levels (P < 0.05). Conclusion: The changes of rCBF and metabolite ratios in the frontal lobe, hippocampus, and posterior cingulate gyrus of patients with primary hypothyroidism can be detected using ASL and MRS techniques. The changes of rCBF and metabolite ratio and their negative correlation with serum TSH level are helpful to explain the causes of brain dysfunction in patients with primary hypothyroidism.


Subject(s)
Creatine , Hypothyroidism , Humans , Creatine/metabolism , Spin Labels , Magnetic Resonance Spectroscopy/methods , Brain/diagnostic imaging , Brain/metabolism , Choline/metabolism , Inositol/metabolism , Hypothyroidism/diagnostic imaging , Hypothyroidism/metabolism , Hypothyroidism/pathology , Thyrotropin
SELECTION OF CITATIONS
SEARCH DETAIL
...