Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Microbiol Spectr ; 10(4): e0115722, 2022 08 31.
Article in English | MEDLINE | ID: mdl-35862982

ABSTRACT

Large-scale head-to-head assessment of the performance of lateral-flow tests (LFTs) for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antigen is required in the context of the continuous emergence of new viral variants. The aim of this study was to evaluate the performance of 22 rapid LFTs for the detection of SARS-CoV-2 antigens. The clinical performance of 22 LFTs was evaluated in 1,157 samples collected in the Greater Paris area. The 8 best-performing LFTs were further assessed for their ability to detect 4 variants of concern (VOC), including the alpha, beta, delta, and omicron (BA.1) variants. The specificity of SARS-CoV-2 LFTs was generally high (100% for 15 of them) but was insufficient (<75%) for 3 tests. Sensitivity of the LFTs varied from 30.0% to 79.7% compared to nucleic acid amplification testing (NAAT). Using a cycle threshold (CT) cutoff of ≤25, sensitivity of the assays ranged from 59.7% to 100%. The 8 best-performing assays had a sensitivity of ≥80% for the detection of the 4 VOC when the CT was ≤25. Falsely negative SARS-CoV-2 antigen LFT results were observed with omicron, due to the occurrence of low viral loads (CT > 30 in 32% of samples) during the two first days following symptom onset. Several LFTs exhibited satisfactory sensitivity and specificity, whereas a few others yielded an unacceptable proportion of false-positive results and/or lacked sensitivity. The sensitivity of the best-performing assays was not influenced by VOC, including alpha, beta, delta, and omicron variants. The ability of LFTs to detect the omicron variant could be reduced during the first days following symptom onset due to lower viral loads than with other variants. IMPORTANCE The use of lateral-flow tests (LFTs) to detect SARS-CoV-2 has expanded worldwide. LFTs detect SARS-CoV-2 viral antigen and are less sensitive than nucleic acid amplification testing (NAAT). Their performance must be evaluated independently of the manufacturers. Our study assessed the performance of 22 SARS-CoV-2 antigen LFTs in large panels of well-characterized samples. The majority of LFTs tested exhibited satisfactory sensitivity and specificity, while some assays yielded unacceptable proportions of false-positive results, and others lacked sensitivity for samples containing large amounts of virus. The sensitivity of the best-performing assays did not vary according to the VOC, including the alpha, beta, delta, and omicron variants.


Subject(s)
COVID-19 , Nucleic Acids , COVID-19/diagnosis , Humans , SARS-CoV-2/genetics , Serologic Tests/methods
2.
J Clin Virol ; 146: 105048, 2022 01.
Article in English | MEDLINE | ID: mdl-34863056

ABSTRACT

Direct detection of SARS-CoV-2 viral antigens could replace RT-PCR, provided that its clinical performance is validated in different epidemiological settings. Here, we evaluated the performance of the VITROS Antigen test, an enzyme immunoassay detecting a SARS-CoV-2 antigen, in NPSs from 3 cohorts of patients. METHODS: Three cohorts including SARS-CoV-2 RNA-positive samples collected during the first and second wave of the French epidemic between March 2020 and February 2021 (including variant B.1.1.7/α and variant B.1.351/ß). RESULTS: Among the 1763 prospectively tested subjects, 8.2% (145/1763) were SARS-CoV-2 RNA-positive by RT-PCR. Using Ct ≤ 30 and Ct ≤ 35 as thresholds, the sensitivities of the antigen assay were 98.8% (93.6-100%) and 93.5% (87.0-97.3%), respectively. The overall specificity of the assay was 100% (1614/1614; 99.8-100%). In a retrospective cohort of subjects infected with variants of concern, 90.4% (47/52) of NPSs containing B. B.1.1.7/α (Ct ≤ 35) and 100% (7/7) of those containing B.1.351/ß were positive with the VITROS EIA SARS-CoV-2 Antigen test. CONCLUSION: The excellent performance of the EIA Antigen test reported here, including in patients infected with viral "variants of concern", support the use of high-throughput, EIA-based SARS-CoV-2 antigen assays as an alternative or complement to nucleic acid testing in order to scale-up laboratory screening and diagnostic capacities.


Subject(s)
COVID-19 , SARS-CoV-2 , Antigens, Viral , Humans , Immunoassay , Immunoenzyme Techniques , RNA, Viral , Retrospective Studies , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...