Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Publication year range
1.
Neuroradiology ; 54(10): 1099-108, 2012 Oct.
Article in English | MEDLINE | ID: mdl-22407410

ABSTRACT

INTRODUCTION: This study was conducted in order to evaluate the value of time-resolved contrast-enhanced magnetic resonance angiography (TR-CE-MRA) with a 3.0-T magnetic field compared to digital subtraction angiography (DSA) as the reference standard for the diagnosis of brain arteriovenous malformation (bAVM). METHODS: Nineteen patients with 19 angiographically confirmed untreated bAVM were investigated with both DSA and TR-CE-MRA for the initial diagnosis. Examinations were compared by two independent readers. Interobserver agreement and intermodality agreement with respect to nidus size, arterial feeders, and venous drainage were determined using the K statistic test. Also, the quality of the TR-CE-MRA images was evaluated. RESULTS: Seventeen of the 19 bAVM (89.5%) detected with DSA were diagnosed with TR-CE-MRA. Interobserver agreement for TR-CE-MRA was good for nidus size, venous drainage, and arterial feeders (K = 0.75, 95% CI 0.50-1.00; K = 0.77, 95% CI 0.54-1.00; and K = 0.80, 95% CI 0.59-1.00 respectively). Intermodality agreement was good for nidus size and venous drainage (K = 0.75, 95% CI 0.49-1.00 and K = 0.77, 95% CI 0.54-1.00, respectively) and moderate for arterial feeders (K = 0.44, 95% CI 0.17-0.70). CONCLUSION: TR-CE-MRA at 3.0 T has a good sensitivity for bAVM detection and good agreement with DSA for determining nidus size and the type of venous drainage, suggesting that TR-CE-MRA is potentially a reliable tool for the diagnosis and assessment of bAVMs. However, it still suffers from low spatial resolution and vessel superposition, making differentiation of the arterial feeders of the nidus difficult at times.


Subject(s)
Angiography, Digital Subtraction/methods , Cerebral Angiography/methods , Intracranial Arteriovenous Malformations/diagnosis , Magnetic Resonance Angiography/methods , Meglumine , Organometallic Compounds , Adolescent , Adult , Aged , Aged, 80 and over , Child , Contrast Media , Female , Humans , Image Enhancement/methods , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , Young Adult
3.
AJNR Am J Neuroradiol ; 27(4): 744-9, 2006 Apr.
Article in English | MEDLINE | ID: mdl-16611757

ABSTRACT

BACKGROUND AND PURPOSE: The aim of this study was to determine the feasibility and usefulness of contrast-enhanced MR angiography (CE-MRA) for the follow-up of intracranial aneurysms treated with detachable coils, by comparing CE-MRA with digital subtraction angiography (DSA) and 3D time-of- flight (TOF) MRA. METHODS: Thirty-two patients with 42 treated aneurysms were included in the study; 6 had been treated for multiple aneurysms. All MRAs were performed with a 1.5T unit within 48 hours of DSA. We performed 2 types of acquisition: a 3D TOF sequence and CE-MRA. Twenty-eight patients were included 1 year after endovascular treatment, and 4 patients, after 3 years or more. DSA was the technique of reference for the detection of a residual neck or residual aneurysm. RESULTS: Compared with DSA, the sensitivity of MRA was good. For the detection of residual neck, there was no significant difference between the results of 3D TOF MRA (sensitivity, 75%-87.5%; specificity, 92.9%, according to both readers) and CE-MRA (sensitivity, 75%-82.1%; specificity, 85.7%-92.9%). For the detection of residual aneurysm, sensitivity and specificity of both techniques were the same, respectively 80%-100% and 97.3%-100%. Therefore, CE-MRA was not better than 3D TOF MRA for the detection of residual neck or residual aneurysm. For large treated aneurysms, there was no difference between decisions regarding further therapy after CE and 3D TOF MRA, even though CE-MRA with a short echotime and enhancement gave fewer artifacts and better visualization of recanalization than 3D TOF MRA. The interpretation of transverse source images and the detection of coil mesh packing seemed easier with 3D TOF imaging. CONCLUSION: This prospective study did not show that CE-MRA was significantly better than 3D TOF MRA for depicting aneurysm or neck remnants after selective endovascular treatment using coils. For aneurysms treated with coils, 3D TOF MRA seems a valid and useful technique for the follow-up of coiled aneurysms.


Subject(s)
Angiography, Digital Subtraction , Contrast Media , Intracranial Aneurysm/diagnosis , Intracranial Aneurysm/surgery , Iopamidol/analogs & derivatives , Magnetic Resonance Angiography , Prostheses and Implants , Adult , Aged , Female , Follow-Up Studies , Humans , Magnetic Resonance Angiography/methods , Male , Middle Aged , Prospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL