Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Materials (Basel) ; 15(13)2022 Jun 23.
Article in English | MEDLINE | ID: mdl-35806555

ABSTRACT

In this paper, an investigation of the properties of Cu and Cu/MgO nanoparticles (NPs) is presented. The NPs were obtained with gas-phase synthesis, and the MgO shells or matrices were formed via the co-deposition method on inert substrates. SEM and AFM were used to investigate the NP morphology on Si/SiOx, quartz, and HOPG. The Cu NPs revealed flattening of their shape, and when they were deposited on HOPG, diffusion and formation of small chains were observed. The embedding of Cu NPs in MgO was confirmed by TEM and EDX maps. XPS showed that Cu was in its metallic state, regardless of the presence of the surrounding MgO. UV-Vis revealed the presence of an intense localized surface plasmon resonance (LSPR) for Cu/MgO and for "bare" NPs. These results confirmed the role of MgO as a protective transparent medium for Cu, and the wavelength position of the LSPR in the Cu/MgO system was consistent with calculations. The wavelength position of the LSPR observed for "bare" and post-oxidized Cu NPs was probably affected by the formation of copper oxide shells after exposure to air. This study paves the way for the use of Cu/MgO NPs as plasmonic nanomaterials in applications such as photovoltaics and sensor technology.

2.
Anal Bioanal Chem ; 407(25): 7757-63, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26253230

ABSTRACT

Proton transfer reaction mass spectrometry (PTR-MS) is a well-established technique for real-time analysis of volatile organic compounds (VOCs). Although it is extremely sensitive (with sensitivities of up to 4500 cps/ppbv, limits of detection <1 pptv and the response times of approximately 100 ms), the selectivity of PTR-MS is still somewhat limited, as isomers cannot be separated. Recently, selectivity-enhancing measures, such as manipulation of drift tube parameters (reduced electric field strength) and using primary ions other than H3O(+), such as NO(+) and O2 (+), have been introduced. However, monoterpenes, which belong to the most important plant VOCs, still cannot be distinguished so more traditional technologies, such as gas chromatography mass spectrometry (GC-MS), have to be utilised. GC-MS is very time consuming (up to 1 h) and cannot be used for real-time analysis. Here, we introduce a sensitive, near-to-real-time method for plant monoterpene research-PTR-MS coupled with fastGC. We successfully separated and identified six of the most abundant monoterpenes in plant studies (α- and ß-pinenes, limonene, 3-carene, camphene and myrcene) in less than 80 s, using both standards and conifer branch enclosures (Norway spruce, Scots pine and black pine). Five monoterpenes usually present in Norway spruce samples with a high abundance were separated even when the compound concentrations were diluted to 20 ppbv. Thus, fastGC-PTR-ToF-MS was shown to be an adequate one-instrument solution for plant monoterpene research.


Subject(s)
Gas Chromatography-Mass Spectrometry/methods , Monoterpenes/analysis , Picea/chemistry , Pinus/chemistry , Volatile Organic Compounds/analysis , Acyclic Monoterpenes , Alkenes/analysis , Alkenes/isolation & purification , Bicyclic Monoterpenes , Bridged Bicyclo Compounds/analysis , Bridged Bicyclo Compounds/isolation & purification , Monoterpenes/isolation & purification , Protons , Volatile Organic Compounds/isolation & purification , Volatilization
3.
J Mass Spectrom ; 50(2): 427-31, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25800025

ABSTRACT

In this study we demonstrate the potential of selective reagent ionisation-time of flight-mass spectrometry for the rapid and selective identification of a popular new psychoactive substance blend called 'synthacaine', a mixture that is supposed to imitate the sensory and intoxicating effects of cocaine. Reactions with H3O(+) result in protonated parent molecules which can be tentatively assigned to benzocaine and methiopropamine. However, by comparing the product ion branching ratios obtained at two reduced electric field values (90 and 170 Td) for two reagent ions (H3O(+) and NO(+)) to those of the pure chemicals, we show that identification is possible with a much higher level of confidence then when relying solely on the m/z of protonated parent molecules. A rapid and highly selective analytical identification of the constituents of a recreational drug is particularly crucial to medical personnel for the prompt medical treatment of overdoses, toxic effects or allergic reactions.


Subject(s)
Illicit Drugs/analysis , Mass Spectrometry/methods , Psychotropic Drugs/analysis , Substance Abuse Detection/methods , Benzocaine/analysis , Benzocaine/chemistry , Illicit Drugs/chemistry , Methamphetamine/analogs & derivatives , Methamphetamine/analysis , Methamphetamine/chemistry , Psychotropic Drugs/chemistry , Thiophenes/analysis , Thiophenes/chemistry
4.
J Phys Chem A ; 118(37): 8229-36, 2014 Sep 18.
Article in English | MEDLINE | ID: mdl-24559481

ABSTRACT

We have investigated the reactions of NO(+), H3O(+), O2(+), and Kr(+) with picric acid (2,4,6 trinitrophenol, C6H3N3O7, PiA) using a time-of-flight mass spectrometer with a switchable reagent ion source. NO(+) forms a simple adduct ion PiA·NO(+), while H3O(+) reacts with PiA via nondissociative proton transfer to form PiAH(+). In contrast, both O2(+) and Kr(+) react with PiA by nondissociative charge transfer to produce PiA(+). For Kr(+), we also observe dissociation of PiA, producing NO2(+) with a branching percentage of approximately 40%. For the reagent ions H3O(+) and O2(+) (and operating the drift tube with normal laboratory air), we find that the intensities of the PiAH(+) and PiA(+) ions both exhibit a peak at a given drift-tube voltage (which is humidity dependent). This unusual behavior implies a peak in the detection sensitivity of PiA as a function of the drift-tube voltage (and hence E/N). Aided by electronic-structure calculations and our previous studies of trinitrotoluene and trinitrobenzene, we provide a possible explanation for the observed peak in the detection sensitivity of PiA.


Subject(s)
Mass Spectrometry/methods , Picrates/analysis , Indicators and Reagents/chemistry , Krypton/chemistry , Nitric Oxide/chemistry , Oxygen/chemistry , Picrates/chemistry , Quantum Theory , Water/chemistry
5.
Int J Mass Spectrom ; 360: 28-38, 2014 Mar 01.
Article in English | MEDLINE | ID: mdl-25844048

ABSTRACT

The rapid expansion in the number and use of new psychoactive substances presents a significant analytical challenge because highly sensitive instrumentation capable of detecting a broad range of chemical compounds in real-time with a low rate of false positives is required. A Selective Reagent Ionisation-Time of Flight-Mass Spectrometry (SRI-ToF-MS) instrument is capable of meeting all of these requirements. With its high mass resolution (up to m/Δm of 8000), the application of variations in reduced electric field strength (E/N) and use of different reagent ions, the ambiguity of a nominal (monoisotopic) m/z is reduced and hence the identification of chemicals in a complex chemical environment with a high level of confidence is enabled. In this study we report the use of a SRI-ToF-MS instrument to investigate the reactions of H3O+, O2+, NO+ and Kr+ with 10 readily available (at the time of purchase) new psychoactive substances, namely 4-fluoroamphetamine, methiopropamine, ethcathinone, 4-methylethcathinone, N-ethylbuphedrone, ethylphenidate, 5-MeO-DALT, dimethocaine, 5-(2-aminopropyl)benzofuran and nitracaine. In particular, the dependence of product ion branching ratios on the reduced electric field strength for all reagent ions was investigated and is reported here. The results reported represent a significant amount of new data which will be of use for the development of drug detection techniques suitable for real world scenarios.

6.
J Mass Spectrom ; 48(9): 1015-8, 2013 Sep.
Article in English | MEDLINE | ID: mdl-24078242

ABSTRACT

The isomers 4-methylethcathinone and N-ethylbuphedrone are substitutes for the recently banned drug mephedrone. We find that with conventional proton transfer reaction mass spectrometry (PTR-MS), it is not possible to distinguish between these two isomers, because essentially for both substances, only the protonated molecules are observed at a mass-to-charge ratio of 192 (C12 H18NO(+)). However, when utilising an advanced PTR-MS instrument that allows us to switch the reagent ions (selective reagent ionisation) from H3O(+) (which is commonly used in PTR-MS) to NO(+), O2(+) and Kr(+), characteristic product (fragment) ions are detected: C4H10N(+) (72 Da) for 4-methylethcathinone and C5 H12N(+) (86 Da) for N-ethylbuphedrone; thus, selective reagent ionisation MS proves to be a powerful tool for fast detection and identification of these compounds.


Subject(s)
Designer Drugs/chemistry , Mass Spectrometry/methods , Methamphetamine/analogs & derivatives , Psychotropic Drugs/chemistry , Indicators and Reagents , Ions/chemistry , Isomerism , Methamphetamine/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...