1.
J Xray Sci Technol ; 30(1): 1-12, 2022.
Article in English | MEDLINE | ID: mdl-34719471

ABSTRACT

High-energy, high-dose, microfocus X-ray computed tomography (HHM CT) is one of the most effective methods for high-resolution X-ray radiography inspection of high-density samples with fine structures. Minimizing the effective focal spot size of the X-ray source can significantly improve the spatial resolution and the quality of the sample images, which is critical and important for the performance of HHM CT. The objective of this study is to present a 9 MeV HHM CT prototype based on a high-average-current photo-injector in which X-rays with about 70µm focal spot size are produced via using tightly focused electron beams with 65/66µm beam size to hit an optimized tungsten target. In digital radiography (DR) experiment using this HHM CT, clear imaging of a standard 0.1 mm lead DR resolution phantom reveals a resolution of 6 lp/mm (line pairs per mm), while a 5 lp/mm resolution is obtained in CT mode using another resolution phantom made of 10 mm ferrum. Moreover, comparing with the common CT systems, a better turbine blade prototype image was obtained with this HHM CT system, which also indicates the promising application potentials of HHM CT in non-destructive inspection or testing for high-density fine-structure samples.


Subject(s)
Radiographic Image Enhancement , Tomography, X-Ray Computed , Phantoms, Imaging , Tomography, X-Ray Computed/methods , X-Rays
2.
Radiother Oncol ; 166: 44-50, 2022 01.
Article in English | MEDLINE | ID: mdl-34774651

ABSTRACT

PURPOSE: This study aimed to evaluate whether high-energy X-rays (HEXs) of the PARTER (platform for advanced radiotherapy research) platform built on CTFEL (Chengdu THz Free Electron Laser facility) can produce ultrahigh dose rate (FLASH) X-rays and trigger the FLASH effect. MATERIALS AND METHODS: EBT3 radiochromic film and fast current transformer (FCT) devices were used to measure absolute dose and pulsed beam current of HEXs. Subcutaneous tumor-bearing mice and healthy mice were treated with sham, FLASH, and conventional dose rate radiotherapy (CONV), respectively to observe the tumor control efficiency and normal tissue damage. RESULTS: The maximum dose rate of HEXs of PARTER was up to over 1000 Gy/s. Tumor-bearing mice experiment showed a good result on tumor control (p < 0.0001) and significant difference in survival curves (p < 0.005) among the three groups. In the thorax-irradiated healthy mice experiment, there was a significant difference (p = 0.038) in survival among the three groups, with the risk of death decreased by 81% in the FLASH group compared to that in the CONV group. The survival time of healthy mice irradiated in the abdomen in the FLASH group was undoubtedly higher (62.5% of mice were still alive when we stopped observation) than that in the CONV group (7 days). CONCLUSION: This study confirmed that HEXs of the PARTER system can produce ultrahigh dose rate X-rays and trigger a FLASH effect, which provides a basis for future scientific research and clinical application of HEX in FLASH radiotherapy.


Subject(s)
Neoplasms , Animals , Clinical Protocols , Humans , Mice , Radiography , Radiotherapy Dosage , X-Rays