1.
J Crit Care ; 29(5): 886.e1-7, 2014 Oct.
Article in English | MEDLINE | ID: mdl-24973106

ABSTRACT

PURPOSE: The purpose of this study is to explore the validity of a novel sedation monitoring technology based on facial electromyelography (EMG) in sedated critically ill patients. MATERIALS AND METHODS: The Responsiveness Index (RI) integrates the preceding 60 minutes of facial EMG data. An existing data set was used to derive traffic light cut-offs for low (red), intermediate (amber), and higher (green) states of patient arousal. The validity of these was prospectively evaluated in 30 sedated critically ill patients against hourly Richmond Agitation Sedation Scale (RASS) assessments with concealment of RI data from clinical staff. RESULTS: With derivation data, an RI less than or equal to 35 had best discrimination for a Ramsay score of 5/6 (sensitivity, 90%; specificity, 79%). For traffic lights, we chose RI less than or equal to 20 as red, 20 to 40 as amber, and more than 40 as green. In the prospective study, RI values were red/amber for 76% of RASS -5/-4 assessments, but RI varied dynamically over time in many patients, and discordance with RASS may have resulted from the use of 1 hour of data for RI calculations. We also noted that red/amber values resulted from sleep, encephalopathy, and low levels of stimulation. CONCLUSIONS: Responsiveness Index is not directly comparable with clinical sedation scores but is a potential continuous alert to possible deep sedation in critically ill patients.


Subject(s)
Arousal , Critical Illness , Deep Sedation , Electromyography/methods , Facial Muscles/physiology , Algorithms , Color , Conscious Sedation , Female , Humans , Hypnotics and Sedatives/administration & dosage , Light , Male , Middle Aged , Prospective Studies , Psychomotor Agitation/diagnosis , ROC Curve , Reference Standards , Reproducibility of Results , Sample Size , Sensitivity and Specificity , Time Factors
2.
Intensive Care Med ; 34(2): 308-15, 2008 Feb.
Article in English | MEDLINE | ID: mdl-17898996

ABSTRACT

OBJECTIVE: To assess whether the Entropy Module (GE Healthcare, Helsinki, Finland), a device to measure hypnosis in anesthesia, is a valid measure of sedation state in critically ill patients by comparing clinically assessed sedation state with Spectral Entropy DESIGN: Prospective observational study. SETTING: Teaching hospital general ICU. PATIENTS AND PARTICIPANTS: 30 intubated, mechanically ventilated patients without primary neurological diagnoses or drug overdose receiving continuous sedation. INTERVENTIONS: Monitoring of EEG and fEMG activity via forehead electrodes for up to 72h and assessments of conscious level using a modified Ramsay Sedation Scale. MEASUREMENTS AND RESULTS: 475 trained observer assessments were made and compared with concurrent Entropy numbers. Median State (SE) and Response (RE) Entropy values decreased as Ramsay score increased, but wide variation occurred, especially in Ramsay 4-6 categories. Discrimination between different sedation scores [mean (SEM) P(K) value: RE 0.713 (0.019); SE 0.710 (0.019)] and between lighter (Ramsay 1-3) vs.deeper (Ramsay 4-6) sedation ranges was inadequate [P(K): RE 0.750 (0.025); SE 0.748 (0.025)]. fEMG power decreased with increasing Ramsay score but was often significant even at Ramsay 4-6 states. Frequent "on-off" effects occurred for both RE and SE, which were associated with fEMG activity. Values switched from low to high values even in deeply sedated patients. High Entropy values during deeper sedation were strongly associated with simultaneous high relative fEMG powers. CONCLUSIONS: Entropy of the frontal EEG does not discriminate sedation state adequately for clinical use in ICU patients. Facial EMG is a major confounder in clinical sedation ranges.


Subject(s)
Conscious Sedation , Critical Illness , Electromyography/drug effects , Hypnotics and Sedatives/pharmacology , Respiration, Artificial , Adolescent , Adult , Aged , Aged, 80 and over , Electroencephalography/drug effects , Entropy , Female , Humans , Male , Middle Aged , Prospective Studies , Statistics, Nonparametric , Time Factors