Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 21(12)2021 Jun 08.
Article in English | MEDLINE | ID: mdl-34201377

ABSTRACT

Over the last decade, manufacturers have come forth with cost-effective sensors for measuring ambient and indoor particulate matter concentration. What these sensors make up for in cost efficiency, they lack in reliability of the measured data due to their sensitivities to temperature and relative humidity. These weaknesses are especially evident when it comes to portable or mobile measurement setups. In recent years many studies have been conducted to assess the possibilities and limitations of these sensors, however mostly restricted to stationary measurements. This study reviews the published literature until 2020 on cost-effective sensors, summarizes the recommendations of experts in the field based on their experiences, and outlines the quantile-mapping methodology to calibrate low-cost sensors in mobile applications. Compared to the commonly used linear regression method, quantile mapping retains the spatial characteristics of the measurements, although a common correction factor cannot be determined. We conclude that quantile mapping can be a useful calibration methodology for mobile measurements given a well-elaborated measurement plan assures providing the necessary data.


Subject(s)
Air Pollutants , Air Pollution , Air Pollutants/analysis , Air Pollution/analysis , Calibration , Environmental Monitoring , Particulate Matter/analysis , Reproducibility of Results
2.
Sensors (Basel) ; 21(3)2021 Jan 26.
Article in English | MEDLINE | ID: mdl-33530337

ABSTRACT

Air pollution in urban areas is a huge concern that demands an efficient air quality control to ensure health quality standards. The hotspots can be located by increasing spatial distribution of ambient air quality monitoring for which the low-cost sensors can be used. However, it is well-known that many factors influence their results. For low-cost Particulate Matter (PM) sensors, high relative humidity can have a significant impact on data quality. In order to eliminate or reduce the impact of high relative humidity on the results obtained from low-cost PM sensors, a low-cost dryer was developed and its effectiveness was investigated. For this purpose, a test chamber was designed, and low-cost PM sensors as well as professional reference devices were installed. A vaporizer regulated the humid conditions in the test chamber. The low-cost dryer heated the sample air with a manually adjustable intensity depending on the voltage. Different voltages were tested to find the optimum one with least energy consumption and maximum drying efficiency. The low-cost PM sensors with and without the low-cost dryer were compared. The experimental results verified that using the low-cost dryer reduced the influence of relative humidity on the low-cost PM sensor results.


Subject(s)
Air Pollutants , Air Pollution , Air Pollutants/analysis , Air Pollution/analysis , Environmental Monitoring , Humidity , Particulate Matter/analysis
3.
Sensors (Basel) ; 20(18)2020 Sep 10.
Article in English | MEDLINE | ID: mdl-32927863

ABSTRACT

Using low-cost gas sensors for air quality monitoring promises cost effective and convenient measurement systems. Nevertheless, the results obtained have a questionable quality due to different factors that can affect sensor performance. The most discussed ones are relative humidity and air temperature. This investigation aimed to assess the behavior of B4-series low-cost gas sensors from Alphasense for measuring CO, NO, NO2, and O3 for different levels of relative humidity and temperature. These low-cost gas sensors were tested for six relative humidity levels from 10% to 85% with increasing steps of 15% and four temperature levels of 10 °C, 25 °C, 35 °C, and 45 °C against reference instruments in the laboratory. The effect of these parameters on low-cost gas sensors was quantified in laboratory from which a correction algorithm was calculated, which was then applied to the field data. The applied algorithm improved the data quality of the low-cost gas sensors in most of the cases. Additionally, a low-cost dryer was assessed to reduce the influence of these factors on the low-cost gas sensors, which also proved to be suitable to enhance the data quality.

SELECTION OF CITATIONS